COLO.Science — WATER QUALITY / ELECTROCHEMISTRY — VIKING-PH200
VIKING-PH200 Benchtop pH Meter
VIKING-PH200 Benchtop pH Meter is a practical laboratory instrument for routine pH, mV and temperature measurement. With a 6.0″ backlit LCD, ±0.01 pH accuracy, 1–3 point pH calibration with NIST buffer recognition, ATC / MTC temperature compensation, Auto-Read / continuous reading modes, Auto-Hold endpoint detection, 50 data sets per parameter and IP54 splash protection, VIKING-PH200 is a cost-effective choice for education, water quality laboratories, food and beverage QA/QC and general benchtop pH/mV measurement.
pH / mV / Temperature
6.0″ backlit LCD
±0.01 pH accuracy
1–3 point calibration
ATC / MTC
Auto-Read / Auto-Hold
50 data sets
IP54
SKU PRO6042
COLO.SCIENCE — ROUTINE BENCHTOP PH / MV / TEMPERATURE METER
Routine benchtop pH meter with 6.0″ LCD, ATC/MTC and Auto-Hold endpoint detection
The VIKING-PH200 Benchtop pH Meter is designed for laboratories that need a simple and robust pH/mV meter for everyday measurements. It combines pH range from −2.00 to 18.00, 0.01 pH resolution, ±0.01 pH accuracy and automatic NIST buffer recognition for routine pH calibration.
With Auto-Read, continuous reading, Auto-Hold endpoint detection, status prompts, ATC / MTC compensation, 50 stored results per parameter and IP54 splash protection, VIKING-PH200 is suitable for water quality laboratories, education, environmental monitoring, food and beverage QA/QC and general benchtop pH/mV tasks.
Key features
- Routine benchtop pH/mV meter for pH, mV and temperature measurement.
- 6.0″ backlit LCD with clear status prompts: Reading / Stable / Locked.
- pH range −2.00 to 18.00 with 0.01 pH resolution and ±0.01 pH accuracy.
- 1–3 point pH calibration with automatic NIST buffer recognition.
- ATC / MTC temperature compensation for flexible work with or without a temperature probe.
- Auto-Read and continuous reading modes with Auto-Hold endpoint detection.
- 50 data sets per parameter for simple recall and basic GLP-style documentation.
- IP54 splash protection, universal AC adapter and compact benchtop format.
Suitable for
- Routine pH measurement in water quality laboratories.
- Drinking water, process water and wastewater control.
- Educational laboratories and student practical work.
- Environmental monitoring and general laboratory screening.
- Food and beverage QA/QC workflows.
- Basic mV / ORP and redox checks with suitable electrodes.
TECHNICAL SPECIFICATIONS — VIKING-PH200 BENCHTOP PH METER
| Model | VIKING-PH200 |
| Product type | Benchtop pH / mV / temperature meter |
| SKU / Product number | PRO6042 |
| Display | 6.0″ high-resolution LCD with backlight |
| Measured parameters | pH / mV / Temperature |
| pH range | −2.00 to 18.00 pH |
| pH resolution | 0.01 pH |
| pH accuracy | ±0.01 pH |
| pH calibration | Up to 3 points; automatic NIST buffer recognition |
| mV / ORP range | −1999 to 1999 mV |
| mV resolution | 1 mV |
| mV accuracy | ±0.1% FS |
| Temperature range | −5 to 110 °C |
| Temperature resolution / accuracy | 0.1 °C · ±0.2 °C |
| Temperature compensation | ATC / MTC |
| Reading modes | Auto-Read and Continuous |
| Status prompts | Reading / Stable / Locked |
| Endpoint detection | Auto-Hold endpoint detection |
| Data management | Up to 50 results per parameter; simple recall for basic GLP documentation |
| pH electrode input | BNC (Q9) |
| Temperature probe input | 4-pin aviation connector |
| Ingress protection | IP54 splash protection |
| Auto shutdown | 300 / 600 / 1200 / 1800 / 3600 s, or Off |
| Power supply | AC adapter: 100–240 V input / DC 9 V output |
| Dimensions / weight | 242 × 195 × 68 mm · 900 g |
| HTML TechSpec | Open VIKING-PH200 technical specification |
Final measurement performance depends on electrode type, buffer quality, sample matrix, temperature compensation mode, calibration procedure, electrode condition and laboratory SOP. Electrode type, buffer set, temperature probe, accessories and final kit contents should be confirmed before quotation.
Standard delivery
- 3-in-1 pH composite electrode PRO4153 or equivalent
- NIST pH buffer solutions 4.01 / 7.00 / 10.01, 50 mL per vial
- Electrode stand EHO5
- AC adapter, 100–240 V AC input / DC 9 V output
Exact kit contents may vary by configuration, stock status and region. Please check the current COLO.Science quotation.
pH, mV and temperature workflow
Routine pH measurement
−2.00 to 18.00 pH range, 0.01 pH resolution and ±0.01 pH accuracy for routine laboratory pH measurement.
mV / ORP mode
−1999 to 1999 mV range with 1 mV resolution supports ORP and general redox checks when suitable electrodes are used.
Endpoint control
Auto-Read, continuous reading and Auto-Hold help operators lock stable results and reduce manual reading errors.
Basic data recall
50 data sets per parameter support simple result recall and basic routine documentation for everyday laboratory use.
MODEL SELECTION NOTE
VIKING-PH200 is a practical routine benchtop pH/mV meter
VIKING-PH200 is suitable when the laboratory needs a robust benchtop pH meter with a larger 6.0″ LCD, simple reading modes, ATC / MTC compensation and basic data memory. For higher precision, larger GLP memory or advanced multi-point calibration, VIKING-PH150 or a higher model may be selected.
COLO.SCIENCE KNOWLEDGE
Learn more about routine pH measurement
Explore COLO.Science resources covering pH theory, NIST buffer selection, pH electrode care, conductivity meters, dissolved oxygen measurement and multi-parameter water quality analyzers.
Applications and laboratory value
Water quality laboratories
VIKING-PH200 supports routine pH, mV and temperature checks in drinking water, process water and wastewater workflows.
Education and training
The large LCD, simple prompts and 1–3 point calibration make the instrument suitable for teaching laboratories and student practice.
Food and beverage QA/QC
Stable pH measurement, ATC / MTC compensation and NIST buffer calibration support routine QC checks in food, beverage and dairy laboratories.
General laboratory screening
Auto-Hold, 50 stored results and IP54 housing make VIKING-PH200 a practical everyday benchtop instrument.
pH electrode care and measurement reliability
Reliable pH measurement depends strongly on electrode care. The pH electrode should be stored in suitable storage solution, rinsed between samples and calibrated with fresh buffer solutions before measurement sessions. Poor electrode storage, contaminated junctions or old buffers can cause slow response, drifting readings and failed calibration even when the meter itself is functioning correctly.
For best results, choose a pH electrode that matches the sample matrix. Standard 3-in-1 glass pH electrodes are suitable for many aqueous samples, while food, low-ionic, spear, flat-surface or special-purpose electrodes may be required for specific laboratory methods.
How to choose the correct VIKING-PH200 configuration
When selecting a benchtop pH meter, the laboratory should define the expected pH range, required accuracy, sample temperature range, electrode type, buffer set, reading mode and documentation requirements. VIKING-PH200 is suitable when the application requires robust routine pH/mV measurement, simple operation, ATC / MTC compensation, NIST buffer recognition and basic result memory.
For routine water quality, education and QA/QC workflows, VIKING-PH200 provides a strong balance between usability, robustness and price. For applications requiring 0.001 pH resolution, larger GLP memory or advanced calibration features, COLO.Science can recommend an alternative VIKING benchtop pH model.
Configuration notice — electrode and delivery kit must be confirmed
VIKING-PH200 should be selected according to measurement range, electrode type, sample matrix, temperature compensation requirements, buffer set, reading mode, documentation needs and final delivery configuration. Available electrode configuration, buffer solutions, electrode stand, adapter and final kit contents should be confirmed before quotation. The content shown on this website is provided for general information and may not represent the final delivered configuration.
VIKING-PH200 — practical benchtop pH meter with 6.0″ LCD
A routine benchtop pH meter for pH, mV and temperature workflows — with 6.0″ backlit LCD, ±0.01 pH accuracy, 1–3 point calibration, ATC / MTC, Auto-Read / Auto-Hold, 50 data sets, IP54 protection and support from COLO.Science.