COLO.Science · Technical Specification
VIKING-PH200
Benchtop pH Meter · pH / mV / Temperature · 6.0″ LCD · IP54
Benchtop pH meter for routine measurement workflows with Auto Read and Continuous modes, Auto-Hold endpoint locking, ATC/MTC temperature compensation and 1–3 point pH calibration with NIST buffer recognition.
pH + mV + temp 6.0" LCD Auto Read Auto-Hold ATC / MTC NIST buffers IP54
Document type: Technical Specification Sheet
Format: Landscape (Word/Outlook-ready)
VIKING-PH200 benchtop pH meter
Instrument
VIKING-PH200 · COLO.Science
Address (HQ)
Polje ob Sotli 4
SI-3255, Slovenia
Contact
Email: sales@colo.si
WhatsApp/Viber: +386 70 713 437
COLO.Science logo VIKING-PH200 · Technical Specification
Document ID: COL-TEC-VIKING-PH200-EN
Version: Landscape
Informational technical sheet · Non-binding · Controlled electronic document

VIKING-PH200 · benchtop pH meter technical specification sheet

pH -2.00 → 18.00 mV -1999 → 1999 Temp -5 → 110°C 0.01 pH IP54 — Routine pH / mV / temperature workflows

📋 general & performance specifications

instrument identity
modelVIKING-PH200
product number (SKU)PRO6042
brand / lineCOLO.Science · COLO Lab Experts
instrument typeBenchtop pH meter (pH / mV / Temperature)
intended useRoutine pH and mV (ORP) measurements with temperature compensation in research, QC and education labs.
pH measurement
pH range-2.00 to 18.00 pH
pH resolution0.01 pH
pH accuracy±0.01 pH
calibration pointsUp to 3 points (1–3)
standard recognitionNIST buffers
mV measurement
mV range-1999 to 1999 mV
mV resolution1 mV
mV accuracy±0.1% FS
temperature measurement
temperature range-5 to 110 °C
unit°C
resolution0.1 °C
accuracy±0.2 °C
measurement workflow & data
reading modesAuto Read, Continuous
reading promptsReading, Stable, Locked
endpoint functionAuto-hold (senses and locks measurement endpoint)
temperature compensationATC, MTC (Automatic / Manual)
data storage50 results (sets) for each parameter
resetFactory reset (restores default settings)
inputs, display & protection
pH electrode inputBNC (Q9)
temperature probe input4-pin aviation connector
displayHigh-resolution LCD, 6.0 inches, backlight: Yes
auto shutdown300 / 600 / 1200 / 1800 / 3600 sec., Off
IP ratingIP54
power & physical
powerAC Adapter, 100–240 V AC input, DC 9 V output
dimensions242 × 195 × 68 mm
weight900 g (1.98 lb)

⚙️ key instrument features

6.0″ LCDHigh-resolution display with backlight for clear readout.
Auto Read + ContinuousSupports stable endpoint reading and continuous monitoring.
Auto-HoldDetects endpoint and locks the final measurement value.
ATC / MTCAutomatic or manual temperature compensation.
GLP-style basicsStores 50 results per parameter for basic record keeping.
IP54Enhanced splash protection for routine wet-bench workflows.

🧪 typical laboratory applications

routine water quality checks (pH with temperature compensation)
education and training labs (electrochemistry basics)
food & beverage QC (pH of raw materials and finished products)
general ORP / redox measurements using mV mode
buffer preparation and routine pH verification

📦 included / typical delivery (reference)

  • VIKING-PH200 benchtop pH meter
  • pH composite electrode
  • NIST pH standard solutions: 4.01 / 7.00 / 10.01 (50 mL per vial)
  • COLO-5 electrode stand
  • AC adapter (100–240 V input, 9 V output)

🧩 options & notes

buffers & consumables For higher throughput, COLO.Science can propose buffer kits, storage solutions, and electrode maintenance accessories.
electrode selection Select the electrode type based on sample matrix (aqueous, viscous, high solids, etc.). Request guidance from COLO.Science.
calibration practice Use fresh NIST buffers and maintain temperature consistency for best repeatability.

🔬 practical operation notes

topicrecommendationnote
calibration Use 2–3 points for critical work; verify slope/offset trend over time NIST buffer recognition supported; keep buffers uncontaminated
temperature Use ATC when available; otherwise keep sample and buffers at similar temperature ATC/MTC supported
electrode care Rinse between samples; store electrode properly after use Maintenance directly impacts stability and drift

📄 reference PDF: VIKING-PH200.pdf
🧪 application guidance: workflow-based electrode selection
🛠️ maintenance: cleaning & periodic inspection
🧾 procurement: binding spec = quotation package

📌 Contact & Support

Headquarters address
Polje ob Sotli 4
SI-3255, Slovenia
Application guidance: tell us your sample type and throughput (routine QC, education, field transfer).
We will propose the matching instrument configuration and electrodes for your workflow.
Quick contact
Web: colo.si
PDF Tech Spec: VIKING-PH200.pdf
Email: sales@colo.si
WhatsApp / Viber: +386 70 713 437
WhatsApp link: wa.me/38670713437
Knowledge hub: COLO.Science
Manufacturer & configuration notice (important):
Specifications in this document are provided for general reference and may represent a typical configuration. COLO reserves the right to change technical specifications without notice.

For procurement and tender purposes, the only valid and binding specification is the official COLO quotation and the accompanying technical specification that is engineering-approved.