RAKAPOSHI-PG plant growth chamber — 310 to 1135 L, LED lighting on every shelf, 3–45 °C
The RAKAPOSHI-PG plant growth chamber series covers reach-in chambers from 310 L to 1135 L for laboratories that need reproducible day and night conditions. Temperature from 3 °C to 45 °C, humidity from 50 % to 90 % RH and LED light up to 300 µmol/m²·s are programmed together in time segments, so a full photoperiod runs automatically for weeks. Every shelf has its own dimmable LED panel. Six models share the same controller, climate system and lighting options; they differ in growing space and footprint, and the PG500D has two separate compartments.
Models and order codes
| Model | Order code | Growing space | Lit shelves | Exterior W × D × H |
|---|---|---|---|---|
| RAKAPOSHI-PG300 | PRO8325 | 310 L | 4 | 770 × 720 × 1730 mm |
| RAKAPOSHI-PG500 | PRO8326 | 501 L | 4 | 900 × 800 × 1940 mm |
| RAKAPOSHI-PG600 | PRO8328 | 603 L | 4 | 900 × 800 × 1940 mm |
| RAKAPOSHI-PG800 | PRO8329 | 790 L | 4 | 1164 × 800 × 1940 mm |
| RAKAPOSHI-PG1000 | PRO8330 | 1135 L | 5 | 1920 × 753 × 2010 mm |
| RAKAPOSHI-PG500D | PRO8327 | 2 × 237 L | 2 × 2 | 900 × 800 × 1940 mm |
All models: 3–45 °C, ±0.5 °C · 50–90 % RH · white LED 300 µmol/m²·s at 10 cm, dimmable 0–100 % · 7″ touch screen, data logger and smartphone app. The same options are available on every model.
Climate and light in one program — for plants from seed to young plant
In a plant growth chamber the plants get the same day every day: the same light, the same temperature and the same humidity, independent of the season and the room. The 7″ touch screen controller sets all three in time segments, so dawn, day, dusk and night follow each other automatically, and light intensity can rise and fall gradually instead of switching on and off.

Key characteristics
- 310 to 1135 L growing space on 4 or 5 lit shelves; fewer shelves as option for taller plants.
- Temperature 3–45 °C with lights on and off, fluctuation ±0.5 °C; option down to −10 °C with lights off.
- Humidity 50–90 % RH by steam humidification; option 30–90 % RH.
- LED panel above every shelf, full-spectrum white 300 µmol/m²·s at 10 cm, dimmable 0–100 %.
- Programs — temperature, humidity and light in the same time segments; real-time programming.
- Data and alarms — internal data logger with USB export, smartphone app, independent over-temperature protection.
Suitable for
- Plant physiology and genetics — Arabidopsis, rice, tobacco and other model plants.
- Crop research on seedlings and young plants — soybean, maize, rapeseed, tomato, pepper, strawberry.
- Germination and seedling tests under defined conditions.
- Temperature, humidity and light-quality stress studies, including red / far-red responses.
- University and school laboratories that grow plants for teaching.
Which size — from one experiment to a whole research group
- PG300 · 310 L — one experiment series or a set of genotypes in 770 × 720 mm of floor area.
- PG500 and PG600 · 501 and 603 L — the same 900 × 800 mm footprint; the PG600 has more height between the shelves.
- PG800 · 790 L — a wider cabinet for more trays per shelf.
- PG1000 · 1135 L — five lit shelves for larger plant numbers in one chamber.
- PG500D · 2 × 237 L — two compartments in one cabinet for two conditions side by side, for example treatment and control.
PG500D · two compartments
Lighting configurations
The standard chamber has full-spectrum white LED panels on all shelves. Another light is chosen at order and fitted on all shelves; each colour is dimmed separately from 0 to 100 %. The intensity for the chosen configuration is stated in the quotation.

Lighting configurations in the chamber
| White · standard | Full spectrum 400–700 nm, 300 µmol/m²·s at 10 cm |
| White · high intensity | 500, 1000 or 1600 µmol/m²·s at 10 cm |
| Single colour | Blue 450 nm, red 660 nm or far-red 735 nm |
| Three colours | Red 660 · blue 450 · far-red 735 nm |
| Four colours | Red · blue · far-red plus white |
| Eighteen colours | 18 wavelengths from UV-A to near infrared |
Same light as stand-alone LUMA panels
| PRO8335 · LUMA-W300 | White 300/500 µmol/m²·s |
| PRO8334 · LUMA-W1000 | White 1000 µmol/m²·s |
| PRO8333 · LUMA-W1600 | White 1600 µmol/m²·s |
| PRO8336 / 8337 / 8338 | Blue · red · far-red panels |
| PRO8339 · LUMA-RBFR350 | Red · blue · far-red, 350 µmol/m²·s |
| PRO8341 · LUMA-18C2000 | Eighteen colours, 2000 µmol/m²·s |
| PRO8342 · PRO8343 | LED controllers, handheld · benchtop |
| PRO8344 · LUMA-SM1 | Spectrometer light meter |
RAKAPOSHI-PG plant growth chamber — technical specifications
Climate and growing space
| Growing space | 310 to 1135 L by model; PG500D two compartments of 237 L |
| Shelves | 4 lit shelves (PG1000: 5; PG500D: 2 per compartment); fewer shelves as option |
| Temperature range | 3–45 °C with lights on and off; option −10 °C to 45 °C (lights off) |
| Temperature fluctuation | ±0.5 °C |
| Temperature display resolution | 0.1 °C |
| Humidity range | 50–90 % RH with lights on and off; option 30–90 % RH |
| Humidification | Steam humidification, capacitive humidity sensor |
| Cooling | Air-cooled compressor refrigeration unit |
| Air circulation | Forced air circulation with fresh-air exchange |
| CO₂ control | Option: ambient to 2000 or 5000 ppm |
Light, control and general data
| Lighting | LED panel above each shelf, full-spectrum white 400–700 nm |
| Light intensity | 300 µmol/m²·s at 10 cm; option 500, 1000 or 1600 µmol/m²·s |
| Light control | 0–100 % dimmable, programmed in time segments with the climate |
| Controller | 7″ touch screen, time-segment and real-time programming, PID control |
| Data · remote access | Internal data logger with USB export · smartphone app |
| Safety | Independent over-temperature protection; high / low temperature and humidity alarms |
| Interior · housing | Stainless steel AISI 304 · powder-coated steel, polyurethane foam insulation |
| Exterior W × D × H | By model — see the table of models |
| Power supply · ambient | 220 V AC, 50 Hz, single-phase · 5–35 °C |
| Series code | RAKAPOSHI-PG |
Operating functions
Day and night programs
Temperature, humidity and light intensity are set for each time segment, and the segments repeat day after day. This makes it possible to simulate a gradual sunrise and sunset and to run long-day or short-day photoperiods without manual switching.
Climate control
Compressor cooling and electric heating keep the temperature with PID control; humidity is added by steam. Air is circulated through the growing space and partly exchanged with fresh air.
Records, alarms and remote access
The internal data logger records the measured values, which are exported via USB in an open format. High and low alarms for temperature and humidity give an audible and visual signal, an independent over-temperature protection switches the heating off, and the smartphone app shows the status and the alarms remotely.
Build, power supply and installation
Stainless steel AISI 304 interior, powder-coated steel housing and one-piece polyurethane foam insulation. The refrigeration unit sits in the base of the cabinet.
The chambers connect to a 220 V, 50 Hz single-phase supply and work at room temperatures from 5 °C to 35 °C. Leave space around the cabinet for the air flow of the refrigeration unit, and check the door and corridor width for the larger models. The mains connection for the chosen model is confirmed in the quotation.
Standard delivery
- Plant growth chamber of the chosen model with lit shelves and white LED panels.
- Mains cable.
- Operating manual.
- Declaration of conformity and warranty documentation.
Options such as the lighting configuration, CO₂ control, low-temperature or wide-humidity range are built in at the factory and ordered together with the chamber. The delivered configuration is the one stated in the COLO.Science quotation.
Technical documents and knowledge base
RAKAPOSHI-PG technical specification (PDF) — all models with dimensions, specifications, lighting and configuration checklist. Testing equipment on COLO.Science — our knowledge base.
Applications and operational value
Plant experiments are only comparable when the conditions are. The RAKAPOSHI-PG plant growth chamber gives every pot on every shelf the same programmed day, and the data logger documents that it did.

Typical work: germination and seedling growth, Arabidopsis and model-plant lines, crop seedlings before transfer to the greenhouse, and experiments with light quality, where red and far-red panels change flowering and stem growth.
For more plants than one cabinet holds, the RAKAPOSHI series continues with walk-in growth rooms, and the same LED panels are available as the stand-alone LUMA line for racks and existing rooms.
Selection guide
- Number of plants. Count the trays or pots per experiment and choose the model by growing space and shelves.
- Plant height. Four or five shelves for seedlings and rosette plants; fewer shelves for taller plants.
- Light level. Standard 300 µmol/m²·s for general growth; 1000 or 1600 µmol/m²·s for light-demanding crops and high-light studies.
- Spectrum. White for growth; three or four colours with far-red for photomorphogenesis and flowering; eighteen colours for spectral research.
- Climate. Below 3 °C or below 50 % RH needs the low-temperature or wide-humidity option.
- Two conditions at once. The PG500D runs two compartments in one cabinet.
Configuration notice
This page is provided for orientation and product selection. It does not replace the binding specification, the delivered configuration or the acceptance criteria confirmed in the official COLO.Science quotation, proforma invoice or order confirmation. Confirm the model, the lighting configuration, the options and the mains supply of the RAKAPOSHI-PG plant growth chamber for the specific order. B2B prices are quoted net, excluding VAT.
Sales and support for international customers
COLO Lab ExpertsPolje ob Sotli 4, SI-3255 Buče, Slovenia
Phone: +386 70 713 437 · Email: sales@colo.si · Web: colo.si