COLO.Science — UV/VIS SCANNING SPECTROPHOTOMETER — NOVEL-900
NOVEL-900 UV/Vis Double Beam Spectrophotometer (190–1100nm)
The NOVEL-900 UV/Vis double beam spectrophotometer is a practical laboratory system for routine photometric work, spectral scanning, quantitative analysis, kinetics, and DNA/protein measurements. With a 190–1100nm wavelength range, five selectable spectral bandwidths, 10.1″ capacitive touch screen, and USB/RS232 connectivity, it offers a strong balance of performance, usability, and flexible workflow support for modern laboratories.
190–1100nm range
0.5 / 1 / 2 / 4 / 5nm bandwidth
10.1″ touch screen
USB / RS232
Wi-Fi UV lamp control option
COLO.SCIENCE – UV/VIS SPECTROPHOTOMETER / NOVEL SERIES
Why NOVEL-900 is a practical UV/Vis spectrophotometer for routine and QC laboratories
The NOVEL-900 UV/Vis scanning spectrophotometer is built on a new optical platform designed to provide strong optical and photometric performance, low stray light, low noise, and stable measurement behavior. Its proportional dual beam design supports repeatable work in laboratories that need reliable transmittance and absorbance data across a broad wavelength range.
This model is suitable for drug inspection, medicine and health, biochemistry, environmental monitoring, commodity inspection, petrochemical laboratories, and other research or quality control environments. It combines touch-screen operation, automatic spectral scanning, quantitative analysis, kinetics, and multi-wavelength measurement in one practical platform for everyday laboratory workflows.
Key features
- Proportional dual beam optical system with 1600 lines/mm optical grating.
- 190–1100nm wavelength range with automatic wavelength setting.
- Selectable spectral bandwidths: 0.5nm, 1nm, 2nm, 4nm, 5nm.
- 10.1″ TFT color capacitive touch screen for curves, menus, data and settings.
- Pre-aligned deuterium lamp and tungsten-halogen lamp with automatic switching.
Where it fits best
- Routine T, A, C and E measurement workflows.
- Spectral scanning and multi-wavelength determination.
- Kinetics, curve fitting, and derivative spectrum work.
- DNA/protein analysis and general life science lab use.
- QC/QA labs that need a stable UV/Vis double beam spectrophotometer.
PRACTICAL USE & WORKFLOW
Why users choose NOVEL-900
NOVEL-900 offers a broad range of measurement modes in a format that is easy to operate. The touch interface helps users review curves, import test data and set parameters directly on the instrument, while professional software is included as standard configuration for extended data handling and method work.
Its hardware and software design supports spectral data processing and storage, automatic scanning measurement, kinetic determination, multi-wavelength analysis and access to print spectrograms and analytical data, making it a strong fit for laboratories that want one flexible UV/Vis platform.
COLO.Science & configuration support
COLO.Science supports UV/Vis spectrophotometer selection according to sample type, required cell holders, bandwidth expectations, data workflow and future accessories. This matters when the laboratory needs more than the basic 1cm cell holder configuration.
Optional accessories for NOVEL-900 include flow cell, Peltier/Sipper system, tube rack, adjustable XY micro cell holder, integrating sphere, film holders and automatic 8-cell holder solutions.
TECHNICAL SPECIFICATIONS — NOVEL-900 UV/VIS DOUBLE BEAM SPECTROPHOTOMETER
| Optical system | Proportional dual beam, optical grating 1600 lines/mm |
| Wavelength range | 190–1100nm |
| Monochromator | Czerny-Turner |
| Focal length | 200mm |
| Spectral bandwidth | 0.5nm, 1nm, 2nm, 4nm, 5nm |
| Wavelength resolution | <1nm |
| Wavelength accuracy | <0.3nm |
| Wavelength repeatability | <0.1nm |
| Photometric accuracy | <0.2%T (0–100%T), ±0.002A (0–0.5A), ±0.004A (0.5–1A) |
| Photometric repeatability | <0.1%T (0–100%T), 0.001A (0–0.5A), 0.002A (0.5–1A) |
| Photometric range | 0–200%T, ±3A |
| Stray light | ≤0.01%T (measured with NaNO2 at 360nm) |
| Stability | ≤±0.0003A/h at 500nm |
| Baseline flatness | ±0.001A |
| Noise | ±0.0005A at 500nm |
| Baseline straightness | ≤±0.0008A (200–1090nm) |
| Baseline drift | 0.0003A/h measured at 250nm and 500nm after 2 hours warm-up |
| Work modes | T, A, C, E; photometric, quantitative, spectral scanning, kinetics, DNA/protein |
| Light source | Pre-aligned D2 lamp + tungsten-halogen lamp, automatic switch-over |
| Scanning speed | Fast / medium / slow (1nm increments) |
| Display | 10.1″ TFT color capacitive touch screen |
| Interfaces | USB / RS232 |
| Power | AC220V ±22V, 50Hz ±1Hz, 200W |
| Instrument size | 590 × 475 × 250mm |
| Packing size / volume | 740 × 630 × 450mm (0.21 cbm) |
| Net / gross weight | 28 / 35kg |
| PDF reference | Open official TechSpec |
Standard configuration
- Spectrophotometer with Euro plug power cable
- 4 pcs glass cuvette
- 2 pcs quartz cuvette
- Instruction manual
Manufacturer reserves the right to change technical specifications without notice.
Configuration notice — UV/Vis spectrophotometers can be configured per application
The official PDF technical specification defines the reference NOVEL-900 configuration. Optional items such as UVwin8 software, 5cm or 10cm cuvette holders, tablet-based wireless control, flow cell, Peltier/Sipper system, tube rack, adjustable XY micro cell holder, integrating sphere, film holders, and auto 8-cell holder should be confirmed according to the user’s application and final quotation.
Applications and laboratory value
Routine UV/Vis analysis
A practical fit for laboratories performing absorbance, transmittance and concentration workflows as part of daily QC, routine testing and standardized laboratory procedures.
Scanning and method work
Supports automatic scanning measurement spectrum, multi-wavelength determination, kinetics and data review for laboratories that need more than basic single-point photometry.
Accessory-based flexibility
NOVEL-900 can be adapted with manual or automatic cell holders, larger path length holders, micro-cell accessories, flow solutions and specialized optical accessories depending on sample type and workflow depth.
Ideal for
- Laboratories looking for a UV/Vis double beam spectrophotometer for routine QC and scanning work
- Users who need 190–1100nm UV/Vis analysis with selectable spectral bandwidths
- Drug inspection, biochemistry, environmental monitoring and petrochemical laboratories
- Teams that value touch-screen operation, USB data output and flexible accessory configuration
- Laboratories planning manual or automatic multi-cell holder workflows
NOVEL-900 — practical UV/Vis double beam performance for routine laboratory analysis
A reliable UV/Vis scanning spectrophotometer for laboratories that need double beam optical stability, broad wavelength coverage, touch-screen usability and application-oriented accessory flexibility — backed by COLO.Science.