Two Shops
One Shipment
,

Salmonella Detection Plate, 20 plates


COLO.Science · Rapid Microbiology

20 plates · ready-to-use detection plate · Salmonella

Salmonella Detection Plate, pack of 20 plates

Salmonella detection · rapid screening

Salmonella Detection Plate – ready-to-use plate for Salmonella screening

The Salmonella Detection Plate is a ready-to-use dry film plate for the detection of Salmonella in food and beverages after enrichment. Suspect colonies are recognised by colour and can be confirmed on the same plate with the Salmonella Confirmation Plate.

  • No media preparation – ready-to-use plates
  • Suspect Salmonella: red to red-brown colonies with a yellow halo
  • Pack of 20 plates · COLO code PRO7369

How the Salmonella Detection Plate works

The plate contains selective nutrients, a cold-water-soluble gelling agent and indicators. After enrichment, a loopful of culture is streaked onto the plate and 1 mL of sterile water is added. During incubation Salmonella forms red to red-brown colonies surrounded by a yellow acid zone, while most other bacteria grow green or without a zone.

Reading the result

Result Reading
Suspect Salmonella red to red-brown colonies with a yellow halo
Other bacteria green colonies or colonies without a halo

Suspect colonies are confirmed with the Salmonella Confirmation Plate or by the culture method.

Technical data

Sample preparation Enrich 25 g of sample in 225 mL of enrichment broth; streak a 1 µL loop onto the plate and add 1 mL of sterile water
Incubation 36 ± 1 °C, 24 ± 2 h, face up
Storage 2–8 °C, sealed; after opening reseal the bag and use within 4 weeks
Shelf life 18 months

Applications and practical notes

The Salmonella Detection Plate is used for fast routine screening of food and beverage samples, as an alternative to plating on selective agars. Typical applications include:

  • routine screening of food and beverages
  • raw material and finished product control
  • hygiene monitoring in food production
  • laboratories with high sample numbers

Working with Salmonella Detection Plate: Streak the enrichment culture evenly and add the sterile water gently so that it spreads over the whole growth area. Incubate the plates face up and do not stack more than 20 plates.

Good practice with rapid tests: store the kit as stated on the label, let the components reach room temperature before use and use each item only once. Record the lot number and the result, and confirm positive results according to the reference method when this is required.

About the Salmonella culture method: the reference method for Salmonella in the food chain, ISO 6579-1, has four steps: non-selective pre-enrichment, selective enrichment in two broths, plating on two selective agars and confirmation of typical colonies. The FDA BAM Chapter 5 follows the same principle with media adapted to different food types. Rapid tests and identification kits shorten the time to result, but positive screening results are usually confirmed by the culture method. COLO.Science offers products for every step, so that one supplier covers the whole procedure.

Complete sets from one supplier: COLO.Science supplies culture media, supplements, rapid tests, identification kits and QC strains as complete sets for the method you follow. Send us your sample types and standards, and we will prepare an offer with the matching products and documentation.

Salmonella Detection Plate is supplied by COLO.Science in the pack sizes listed under Ordering information. For larger quantities, regular deliveries or method-specific sets that include Salmonella Detection Plate, please send us a request. With every delivery of Salmonella Detection Plate you receive the lot number and expiry date, and on request we send the available documentation for Salmonella Detection Plate.

Where the Salmonella Detection Plate fits in the workflow

  1. Enrichment – sample in Buffered Peptone Water or enrichment broth
  2. Rapid screening – detection plate, LAMP or real-time PCR
  3. Confirmation – confirmation plate or culture method (XLD Agar, TSI, latex)
  4. Report – negative results reported the next day; positives confirmed

See the complete Salmonella set in the Microbiology Catalogue →

Ordering information

Product COLO code Pack
Salmonella Detection Plate PRO7369 20 plates
Salmonella Confirmation Plate PRO7370 5 discs
Buffered Peptone Water, dehydrated PRO7434 500 g

Product notice: preparation, storage conditions and shelf life are given on the label. Technical data on this page are for orientation; the label and the lot documentation apply. B2B prices are quoted net, excluding VAT.

Sales and technical support

COLO LabExperts

Polje ob Sotli 4, SI-3255, Slovenia

Phone / Viber / WhatsApp: +386 70 713 437
Email: sales@colo.si
Web: colo.si

Quotations and technical support for culture media and microbiology products across our international sales territory. B2B prices are net, excluding VAT.

COLO.SCIENCE | MICROBIOLOGY SUPPORT

Need the complete set for your method?

Send the sample type, target organism and the standard you follow. COLO.Science will put together the media, supplements, QC strains and confirmation tests for the whole procedure.

SKU: PRO7369 Categories: ,

Request a Quote