VIKING-M600 — Benchtop Multi-Parameter Analyzer (pH / EC / ISE / DO / Temp.)
OVERVIEW
VIKING-M600 by COLO.Science is a touchscreen benchtop
multi-parameter analyzer designed for precise measurement of
pH, conductivity (EC), ion concentration (ISE) and
dissolved oxygen (DO), with temperature compensation, GLP-compliant data storage
and smart, guided workflows.
With a 7.0″ color LCD, modular channels (pH/ISE, EC, DO) and up to
1000 stored results per parameter, VIKING-M600 is ideal for water laboratories,
environmental monitoring, industrial QC and research applications that require traceable
multi-parameter analysis at the bench.
COLO.SCIENCE KNOWLEDGE
Water quality and multi-parameter analysis in practice
Explore COLO.Science articles on water quality, pH, conductivity and dissolved oxygen,
including practical examples using benchtop and portable multi-parameter analyzers.
KEY FEATURES & MODULES
General features
- 7.0″ high-contrast color LCD touchscreen with intuitive interface.
- Smart OS with user, calibration, method and data management.
- Multi-reading modes: auto-read, timed-read, continuous-read.
- Automatic/Manual temperature compensation for accurate results.
- Data storage: 1000 sets per parameter (GLP-compliant) with data review, comparison and recalculation.
- USB and RS-232 communication; supports USB 2.0 flash drive and printer.
- Factory reset to default options; IP54 splash-resistant housing.
- Modular design: pH/ISE, Conductivity and Dissolved Oxygen modules;
four channels configurable in any combination.
pH measurement
- 1–6 point calibration with standard recognition.
- Buffer groups: NIST, DIN, GB; custom buffer group supported.
- Automatic electrode diagnostics with slope and offset display.
Ion (ISE)
- 1–6 point calibration.
- Units: μg/L, mg/L, g/L, mmol/L, pX, ppm, etc.
- Modes: Direct Reading, Standard Addition, Sample Addition, GRAN.
- 10+ built-in methods (F−, Cl−, Br−, I−, NO₃−, BF₄−, NH₄⁺, K⁺, Na⁺, Ca²⁺, Cu²⁺, Pb²⁺, Ag⁺, etc.) plus user methods.
Conductivity (EC)
- 1–5 point calibration with standard recognition.
- Settable parameters: cell constant, reference temperature (5/10/15/18/20/25 °C),
temperature coefficient, TDS factor. - Temperature compensation types: none, linear, pure water.
Dissolved Oxygen (DO)
- Calibration with air-saturated water or zero oxygen.
- Automatic barometric pressure compensation; manual salinity factor correction.
- Selectable pressure units: kPa, mbar, Torr, Atm.
Standard delivery
- pH composite electrode PRO6139.
- Conductivity electrode.
- Temperature probe PRO6170.
- DO electrode (polarographic) PRO6165.
- NIST pH standards 4.01 / 7.00 / 10.01 (50 ml each).
- EC standard 1413 μS/cm (50 ml).
- EHO-3 electrode stand; touch pen.
TECHNICAL SPECIFICATIONS
Overview
| Model | VIKING-M600 |
|---|---|
| Parameters | pH / EC / ISE / DO / Temp. (mV / ORP / pX / Resistivity / TDS / Salinity / DO %Saturation) |
pH
| Range | −2.000 to 20.000 pH |
|---|---|
| Resolution | 0.1, 0.01, 0.001 pH |
| Accuracy | ±0.002 pH |
| Calibration points | Up to 6 |
| Standard customization | Yes |
| Calibration reminder | Yes |
| Standard recognition | NIST, GB, DIN |
| Slope limit | Yes |
mV / ORP
| Range | −2000.00 to 2000.00 mV |
|---|---|
| Resolution | 0.1, 0.01 mV |
| Accuracy | ±0.1 mV or ±0.03% |
| EH ORP mode | Yes |
| ORP calibration | 1–2 custom points (relative mV) |
pX
| Range | −2.000 to 20.000 pX |
|---|---|
| Resolution | 0.1, 0.01, 0.001 pX |
| Accuracy | ±0.002 pX |
| Calibration points | Up to 6 |
ISE (Ion-Selective)
| Range | 1.000e−9 to 9.999e+9 |
|---|---|
| Units | mol/L, mmol/L, g/L, mg/L, μg/L |
| Resolution | Up to 4 significant digits |
| Accuracy | ±0.3% |
| Calibration points | Up to 6 |
Conductivity / Resistivity / TDS / Salinity
| Conductivity range | 0.000 μS/cm to 3000 mS/cm |
|---|---|
| Resolution (EC) | min 0.001 μS/cm (range-dependent) |
| Accuracy (EC) | ±0.5% FS |
| Reference temperature | 5, 10, 15, 18, 20, 25 °C |
| EC calibration | Up to 5 points |
| Standard recognition | 146.5 μS/cm, 1408 μS/cm, 12.85 mS/cm, 111.3 mS/cm |
| Resistivity | 5.00 Ω·cm to 100.0 MΩ·cm (min res. 0.01 Ω·cm) |
| TDS | 0.000 mg/L to 1000 g/L (min res. 0.001 ppm; range-dependent) |
| Salinity type | %NaCl |
| Salinity range | 0.00–8.00 % |
| Salinity resolution | 0.01 % |
| Salinity accuracy | ±0.1 % |
Dissolved Oxygen (polarographic)
| Concentration range | 0.00 to 99.99 mg/L |
|---|---|
| Concentration resolution | 0.01 mg/L |
| Concentration accuracy | ±0.1 mg/L |
| % Saturation range | 0.0 to 600 % |
| % Saturation resolution | 0.10 % |
| % Saturation accuracy | ±2.0 % |
| Calibration | Air-saturated water or zero point |
| Barometric compensation | Automatic |
| Salinity correction | Manual factor |
| Calibration reminder | Yes |
Temperature & measurement
| Temperature range | −5 to 130 °C |
|---|---|
| Units | °C |
| Resolution | 0.1 °C |
| Accuracy | ±0.1 °C |
| Reading modes | Auto (Fast/Medium/Slow), Timed, Continuous |
| Prompts | Reading, Stable, Locked |
| Temp. compensation | ATC, MTC |
Memory & data
| Data storage | 1000 groups (per parameter) |
|---|---|
| GLP features | Yes |
| Log management | Yes |
Inputs & outputs
| pH electrode | BNC (Q9) |
|---|---|
| DO + Temp. probe | 6-pin Mini-DIN |
| Conductivity + Temp. probe | 8-pin Mini-DIN |
| Outputs | USB, RS-232; USB 2.0 flash device; printer; PC |
Display & power
| Backlight | Yes |
|---|---|
| Auto shutdown | 1–60 min, or off |
| IP rating | IP54 |
| Date & time | Yes |
General
| Power | AC adapter, 100–240 V AC input, 24 V DC output |
|---|---|
| Dimensions | 280 × 280 × 130 mm |
| Net weight | 2500 g (5.51 lb) |
| Carton | 370 × 305 × 330 mm |
| Shipping weight | 4 kg |