MBIND65 — Microbiological Incubator, 65 L Natural Convection
OVERVIEW
MBIND series microbiological incubators from COLO.Science are designed as reliable workhorses for routine microbiology, food and pharma stability testing, and general cell and bacteria incubation. Natural air circulation gently distributes heat without a fan, providing high temperature uniformity in the chamber while minimizing vibration and reducing the risk of sample cross-contamination.
MBIND65 is the 65 L class natural-convection incubator in this series. It combines an LED display with intelligent PID temperature control, a double-layer door with inner tempered-glass observation window, and a robust stainless-steel chamber for easy cleaning and long-term use. A built-in timer (1 minute to 99 days) starts only once the setpoint is reached, while an integrated over-temperature limiter (DIN 12880 Class 3.1) with audible and visual alarm safeguards your samples and your workflows.
COLO.SCIENCE KNOWLEDGE
Natural convection incubators in microbiology workflows
Discover best practices for microbiological incubation, temperature stability, and contamination control in our COLO.Science knowledge hub.
TYPICAL APPLICATIONS
- Incubation of microbial cultures (bacteria, yeast, fungi) at controlled temperatures
- Quality control in food, beverage and dairy laboratories
- Stability tests and incubation tasks in pharmaceutical and cosmetic production
- Environmental and water microbiology testing
- General microbiology teaching and routine laboratory work
- Sample storage at elevated and constant temperatures
- Long-term incubation protocols requiring quiet, fanless operation
MODELS & DIMENSIONS — MBIND SERIES
| Model | Chamber volume (L) | Inner chamber (W×D×H, mm) | Outer dimensions (W×D×H, mm) | Power / energy at 37 °C |
|---|---|---|---|---|
| MBIND45 | 45 | 350 × 350 × 350 | 525 × 480 × 620 | 0.35 kW / ≈20 Wh/h |
| MBIND55 | 53 | 370 × 350 × 420 | 520 × 540 × 710 | 0.20 kW / ≈23 Wh/h |
| MBIND65 (this page) | 65 | 400 × 350 × 440 | 614 × 577 × 625 | 0.45 kW / ≈25 Wh/h |
| MBIND125 | 120 | 500 × 450 × 550 | 675 × 580 × 820 | 0.60 kW / ≈40 Wh/h |
| MBIND210 | 210 | 600 × 580 × 600 | 775 × 710 × 870 | 0.70 kW / ≈60 Wh/h |
TECHNICAL SPECIFICATIONS — MBIND65
| Model | MBIND65 Microbiological Incubator |
| Incubator type | Natural air circulation microbiological incubator, standard laboratory version |
| Temperature range | RT +5 °C to 80 °C (room temperature dependent) |
| Temperature resolution / setting accuracy | 0.1 °C |
| Temperature uniformity & fluctuation (typical) | ±0.6 °C / ±0.2 °C at 37 °C; ±1.0 °C / ±0.3 °C at 50 °C |
| Control system | Microprocessor PID controller, two-temperature-section control, sensor deviation correction, auto-tuning |
| Display | Backlit LED display showing set/actual temperature, time, and operating status (°C/°F selectable) |
| Timer function | 1 minute to 99 days with “wait-until-at-setpoint” function; process time starts after reaching set temperature |
| Over-temperature protection | Integrated independent temperature safety device, DIN 12880 Class 3.1, with visual and audible alarm |
| Alarms & safety functions | Over-temperature alarm, error status alarm, timing completion, internal parameter lock, power-failure memory |
| Air circulation | Natural convection, no internal fan; adjustable exhaust air flap on top with stainless-steel cap |
| Temperature sensor | Pt100 resistance temperature detector, DIN Class A, 4-wire circuit |
| Door design | Double-layer door; inner tempered-glass observation door with silicone packing, outer insulated metal door with magnetic seal |
| Chamber construction | Corrosion-resistant stainless-steel inner chamber with rounded corners for easy cleaning; cold-rolled steel housing with electrostatic powder coating |
| Shelves (standard / max) | 2 stainless-steel shelves supplied as standard; up to 9 shelves maximum (optional) |
| Protection class | IP20 (housing), according to EN 60529 |
| Applications focus | Routine microbiology, food & beverage QC, pharmaceutical and cosmetics incubation, general laboratory incubation tasks |
STANDARD DELIVERY & ACCESSORIES
- MBIND65 microbiological incubator, natural air convection
- Two stainless-steel shelves (standard configuration)
- Power cable and basic user manual / quick start guide
- Standard temperature certificate at 40 °C (chamber centre), issued by COLO technical service
- Integrated PID controller with LED display and over-temperature limiter (DIN 12880 Class 3.1)
- Documentation set (wiring and operating parameters as per current catalog)
- Optional: additional stainless-steel or PE-coated wire shelves
- Optional: RS485/communication interface and external printer
- Optional: program temperature control device and remote monitoring / WF control
- Optional: controller with ramp settings, USB data storage, touch-screen display upgrade (where available)
Exact scope of supply and optional accessories as per current COLO.Science catalog and order confirmation.
MAIN TECHNICAL PARAMETERS — MBIND65
| Model | MBIND65 — Microbiological Incubator, natural convection |
| Working / chamber volume | ≈62 L useable chamber (65 L class) |
| Temperature range | RT +5 °C to 80 °C |
| Temperature resolution / setting | 0.1 °C steps, digital setting via PID controller |
| Uniformity & fluctuation (typical) | ±0.6 °C / ±0.2 °C at 37 °C; ±1.0 °C / ±0.3 °C at 50 °C |
| Heat-up time | ≈25–30 minutes to 37 °C; ≈40 minutes to 50 °C (typical values) |
| Timer range | 1 minute–99 days with timing wait function (start after reaching setpoint) |
| Inner chamber size (W×D×H) | 400 × 350 × 440 mm |
| Outer dimensions (W×D×H) | 614 × 577 × 625 mm |
| Standard shelves / max shelves | 2 shelves supplied / up to 9 shelves maximum |
| Permitted load | Total load up to 45 kg; max. load per rack 16 kg |
| Net / gross weight | ≈32 kg / 35 kg |
| Power supply | 220–230 V AC, 50/60 Hz |
| Rated power / energy use | 0.45 kW installed power; ≈25 Wh/h at 37 °C |
| Installation clearances | Back ≥160 mm; sidewise ≥100 mm (for ventilation and service access) |