Two Shops
One Shipment

SIRET analytical balances 120–400 g / 0.1 mg with Internal calibration


SIRET analytical balances; 100 / 120 / 220 / 320 g; 0.1 mg readability; Class I; internal calibration; EMFC sensor; repeatability ±0.2 mg; linearity ±0.0003 g; backlit LCD; RS232 standard / USB optional; Ø80 mm pan standard, Ø90 mm optional; glass windshield; optional printer/E2 weights.

COLO.Science — WEIGHING / ANALYTICAL BALANCES — SIRET SERIES

SIRET analytical balances 100–320 g / 0.1 mg with internal calibration, EMFC sensor and backlit LCD

SIRET analytical balances are high-precision laboratory balances for demanding 0.1 mg analytical weighing. The series includes ANB-SIRET100, ANB-SIRET120, ANB-SIRET220 and ANB-SIRET320 models, with internal calibration, electromagnetic monoblock force compensation, Class I accuracy, backlit LCD display, RS232 standard output and a three-sided glass windshield for stable routine laboratory weighing.

COLO.SCIENCE — 0.1 MG ANALYTICAL LABORATORY WEIGHING

Internal calibration and EMFC weighing performance for controlled laboratory work

SIRET analytical balances are intended for laboratories that require 0.1 mg readability, stable analytical weighing and a compact enclosed weighing chamber. The model range from 100 g to 320 g allows the user to select the balance according to sample mass, container size, tare requirement and laboratory method.

The series uses electromagnetic monoblock force compensation, internal calibration, a backlit LCD display, stainless-steel weighing pan, RS232 standard communication and optional USB / software configuration. The three-sided glass windshield helps reduce air-flow influence during small-mass weighing.

Key characteristics

  • Models: ANB-SIRET100, ANB-SIRET120, ANB-SIRET220 and ANB-SIRET320.
  • Capacity range: 100 / 120 / 220 / 320 g.
  • Readability: 0.1 mg / 0.0001 g.
  • Accuracy class: Class I.
  • Calibration: internal calibration.
  • Sensor: electromagnetic monoblock force compensation.
  • Display: backlit LCD display.
  • Interface: RS232 standard; USB optional.
  • Pan size: Ø80 mm stainless steel standard; Ø90 mm optional.

Suitable for

  • Analytical weighing of small samples with 0.1 mg readability.
  • Quality control, sample preparation and formulation work.
  • Laboratory weighing where internal calibration simplifies routine use.
  • Mass comparison, routine control weighing and method verification.
  • Optional printer or PC documentation workflows.
  • Laboratories that need a compact analytical balance with glass windshield.

SIRET SERIES — INTERNAL CALIBRATION ANALYTICAL BALANCES

SIRET analytical balances for 0.1 mg laboratory weighing

SIRET analytical balances are suitable when a laboratory needs 0.1 mg readability, internal calibration and stable analytical weighing inside a glass windshield chamber. The series provides four capacity choices: 100 g, 120 g, 220 g and 320 g, all with the same 0.1 mg readability and Class I analytical balance positioning.

The SIRET analytical balances page is structured for clear model selection: capacity, readability, resolution divisions, calibration type, display, interface and pan size are shown separately, so the user can compare models without mixing standard features with optional configuration items.

For documented laboratory work, SIRET analytical balances can be combined with optional printer, optional USB interface, optional data software and optional OIML E2 control weights. The exact data workflow, software functions, control-weight values, certificates and delivered configuration should be confirmed in the official quotation.

SIRET analytical balance, E2 control weights and optional printer

SIRET analytical balance with backlit LCD, internal calibration and glass windshield

SIRET analytical balances cover 100–320 g capacity with 0.1 mg readability, internal calibration, EMFC sensor, backlit LCD and glass windshield.

Optional OIML E2 control weights for SIRET analytical balance routine verification

Optional OIML E2 control weights can be selected for independent routine checks, SOP control points, audit support and documented balance verification.

Optional thermal printer for SIRET analytical balance measurement records

Optional thermal printer supports paper printout of weighing results when laboratory procedures require direct measurement records.

SIRET series — model variants and catalogue selection parameters

ANB-SIRET100

Capacity: 100 g
Readability: 0.1 mg
Resolution: 1,000,000 divisions
Calibration: Internal
Accuracy class: Class I
Display: Backlit LCD
Interface: RS232 standard; USB optional

ANB-SIRET120

Capacity: 120 g
Readability: 0.1 mg
Resolution: 1,200,000 divisions
Calibration: Internal
Accuracy class: Class I
Display: Backlit LCD
Interface: RS232 standard; USB optional

ANB-SIRET220

Capacity: 220 g
Readability: 0.1 mg
Resolution: 2,200,000 divisions
Calibration: Internal
Accuracy class: Class I
Display: Backlit LCD
Interface: RS232 standard; USB optional

ANB-SIRET320

Capacity: 320 g
Readability: 0.1 mg
Resolution: 3,200,000 divisions
Calibration: Internal
Accuracy class: Class I
Display: Backlit LCD
Interface: RS232 standard; USB optional

Model note: this page uses ANB-SIRET100, ANB-SIRET120, ANB-SIRET220 and ANB-SIRET320. Final model SKU, optional USB interface, printer, software, E2 control weights, certificates and delivered configuration should be confirmed in the official quotation.

TECHNICAL SPECIFICATIONS — SIRET ANALYTICAL BALANCE SERIES

Product series SIRET analytical balances
Model variants ANB-SIRET100 / ANB-SIRET120 / ANB-SIRET220 / ANB-SIRET320
Balance type Analytical balance · Class I
Maximum capacities 100 / 120 / 220 / 320 g
Readability 0.1 mg / 0.0001 g
Resolution divisions 1,000,000 / 1,200,000 / 2,200,000 / 3,200,000 divisions by model
USP minimum sample weight 400 mg (k = 2, U = 0.1%)
Repeatability ±0.2 mg
Reproducibility 0.0002 g
Linearity ±0.0003 g
Eccentric loading at 1/3 Max 0.500 mg
Stabilization time ≤ 3 seconds
Sensor Electromagnetic monoblock force compensation
Calibration Internal calibration
Operating temperature 10–30 °C
Relative humidity 20–85% RH
Power supply 110–230 V, 50–60 Hz by adapter
Display Backlit LCD display
Interface RS232 standard; USB optional
Pan size Ø80 mm stainless steel standard; Ø90 mm optional
Windshield 175 × 175 × 230 mm (W × D × H)
Measuring chamber 170 × 160 × 205 mm (W × D × H)
Housing size 230 × 310 × 330 mm (W × D × H)
G.W. / N.W. 7.5 / 5.5 kg

Final weighing performance depends on correct installation, environmental stability, levelling, warm-up routine, internal calibration procedure, vibration control, weighing vessel, sample handling and laboratory control-weight practice. Final model, optional USB, printer, software, control weights, certificates and documentation are confirmed in the official quotation.

STANDARD PACKAGING / STANDARD DELIVERY

Standard SIRET package

Included in standard packaging

  • Selected SIRET analytical balance.
  • Glass windshield / weighing chamber.
  • Power cable / power adapter.
  • Instruction manual / user guide.

Optional accessories

  • Printer.
  • USB interface / USB workflow.
  • Data software.
  • OIML E2 control weights and certificates.
  • Hydrostatic density set.

Operating functions and data workflow

Analytical weighing

0.1 mg readability supports precise weighing of laboratory samples, standards, formulation components and QC check samples.

Counting and percent weighing

Parts counting and percent weighing can support routine laboratory comparison and sample-control workflows where reference mass is appropriate.

Optional data workflow

RS232 is the standard interface. USB interface, data collection software, printer workflow and software-assisted export functions are optional and should be confirmed before quotation.

Density workflow

Density weighing should be treated as a configuration-dependent workflow and confirmed together with the required hydrostatic set and laboratory method.

OPTIONAL ACCESSORIES AND CONTROL WEIGHTS

Optional E2 control weights, printer, USB and software workflow

SIRET analytical balances use internal calibration. Certified OIML E2 control weights may still be selected as optional accessories for independent routine verification, SOP control checks and audit support. Printer, USB and software workflow are optional and should be defined before quotation.


OIML E2 control weights for SIRET analytical balance routine verification

OIML E2 control weights

Recommended for independent routine checks, control points around working mass values, audit support and documented balance verification procedures.

Open E2 weights

Optional thermal printer for SIRET analytical balance weighing records

Optional thermal printer

Supports printed measurement records when laboratory procedures require direct printout of weighing results.

Optional communication workflow

  • RS232 standard interface.
  • USB interface optional.
  • Data collection software optional.
  • Printer workflow optional.
  • Final interface and software functions should be confirmed before ordering.

Ordering note: confirm the selected SIRET model, required pan size, optional USB, printer, software, E2 control-weight values, certificates, hydrostatic set and final documentation package in the official quotation.

WEIGHING CATALOGUE

Compare analytical balances, milligram balances and E2 control weights

Use the weighing catalogue to compare SIRET models with other analytical balances, milligram balances, precision balances, calibration weights and weighing accessories.

Open catalogue →

COLO.SCIENCE KNOWLEDGE AND SUPPORT

Selection support for analytical balances, internal calibration and E2 control weights

COLO.Science supports complete weighing configurations: model selection, internal calibration routine, control-weight selection, printer workflow, RS232 / optional USB data workflow, software options and documentation requirements for laboratory users.

COLO.Science →

How to select the appropriate SIRET model

When selecting a SIRET analytical balance, first define the maximum total mass on the pan: sample, container, weighing vessel and any accessories used during the method. ANB-SIRET100 and ANB-SIRET120 are practical for smaller sample work, while ANB-SIRET220 and ANB-SIRET320 provide more capacity for larger containers or higher total load.

The second selection step is documentation and control. Confirm whether RS232 is sufficient or optional USB / software is required, whether printed records are needed, whether E2 control weights and certificates should be supplied, and whether a hydrostatic density set is required for the intended method.

SIRET analytical balances for 0.1 mg weighing with internal calibration

SIRET analytical balances are intended for laboratories that need reliable 0.1 mg weighing, internal calibration, electromagnetic monoblock force compensation and a stable glass windshield chamber. The series covers 100 g, 120 g, 220 g and 320 g models and supports routine analytical weighing, sample preparation, QC control, formulation work, mass comparison and documented laboratory weighing procedures.

In practical use, SIRET performance depends on correct installation, stable temperature, suitable weighing bench, proper levelling, internal calibration routine, vibration control, warm-up time and suitable control-weight practice. Optional E2 control weights, printer, optional USB interface, data software and hydrostatic set can be added according to the laboratory method and documentation requirements.

Configuration notice

SIRET analytical balances may be supplied with different configurations depending on selected model, pan size, optional USB interface, optional data software, printer, E2 control weights, certificates, hydrostatic kit and documentation requirements. This page uses the safe wording “internal calibration” and does not use unconfirmed claims such as dual-range weighing, true-colour touch screen operation, built-in date/time/temperature records or real-time temperature compensation. The official quotation defines the final delivered configuration. Specifications may change without notice.

Need help choosing a SIRET analytical balance?

Contact COLO.Science to confirm the SIRET model, weighing range, 0.1 mg readability requirement, internal calibration routine, pan size, optional USB, printer, software, E2 control weights, certificates, hydrostatic set and final delivered configuration.

Balance Types

Analytical Balances

,

Request a Quote