Two Shops
One Shipment
,

Rapid Aerobic Count Plate for Membrane Filtration, 20 plates


COLO.Science · Count Plates

20 plates · ready-to-use count plate · total viable count in water by membrane filtration

Rapid Aerobic Count Plate for Membrane Filtration, pack of 20 plates

Hygiene indicators · count plate

Rapid Aerobic Count Plate for Membrane Filtration – ready-to-use plate for total viable count in water by membrane filtration

The Rapid Aerobic Count Plate for Membrane Filtration is a ready-to-use dry film plate for total viable count in water by membrane filtration. No media preparation, pouring or melting of agar is needed – the sample is applied, incubated and the colonies are counted directly on the plate.

  • Ready to use, no media preparation
  • Results read directly on the plate
  • Pack of 20 plates · COLO code PRO7376

How the Rapid Aerobic Count Plate for Membrane Filtration works

The membrane with the retained bacteria is placed on the moistened plate. Nutrients diffuse through the membrane and chromogenic indicators colour the growing colonies, which can be counted directly on the membrane grid.

Reading the plate

Colonies What to count
Coloured colonies on the membrane count all coloured colonies

Count plates with a well-countable number of colonies and multiply the result by the dilution factor.

Technical data

Sample preparation Filter at least 10 mL of sample, rinse with at least 15 mL saline; wet the plate with 1 mL saline for about 2 min and place the membrane grid side down
Incubation 36 ± 1 °C, 24 ± 2 h (can be extended), face up
Storage 2–8 °C, sealed; after opening reseal the bag and use within 4 weeks
Shelf life 18 months

Applications and practical notes

The Rapid Aerobic Count Plate for Membrane Filtration is used in routine hygiene control and product testing in food, beverage and water laboratories. Typical applications include:

  • drinking and process water
  • bottled water and beverages
  • rinse water and CIP control
  • liquid raw materials

Working with Rapid Aerobic Count Plate for Membrane Filtration: Place the membrane grid side down without trapping air bubbles and make sure the plate is evenly moistened before the membrane is applied. Incubate the plates face up.

Good practice with rapid tests: store the kit as stated on the label, let the components reach room temperature before use and use each item only once. Record the lot number and the result, and confirm positive results according to the reference method when this is required.

About the Salmonella culture method: the reference method for Salmonella in the food chain, ISO 6579-1, has four steps: non-selective pre-enrichment, selective enrichment in two broths, plating on two selective agars and confirmation of typical colonies. The FDA BAM Chapter 5 follows the same principle with media adapted to different food types. Rapid tests and identification kits shorten the time to result, but positive screening results are usually confirmed by the culture method. COLO.Science offers products for every step, so that one supplier covers the whole procedure.

Complete sets from one supplier: COLO.Science supplies culture media, supplements, rapid tests, identification kits and QC strains as complete sets for the method you follow. Send us your sample types and standards, and we will prepare an offer with the matching products and documentation.

Rapid Aerobic Count Plate for Membrane Filtration is supplied by COLO.Science in the pack sizes listed under Ordering information. For larger quantities, regular deliveries or method-specific sets that include Rapid Aerobic Count Plate for Membrane Filtration, please send us a request. With every delivery of Rapid Aerobic Count Plate for Membrane Filtration you receive the lot number and expiry date, and on request we send the available documentation for Rapid Aerobic Count Plate for Membrane Filtration.

Where the Rapid Aerobic Count Plate for Membrane Filtration fits in the counting procedure

  1. Filtration – at least 10 mL of sample through a membrane filter
  2. Rinsing – rinse with at least 15 mL of sterile diluent
  3. Transfer – membrane placed grid side down on the moistened plate
  4. Incubation and counting – count the coloured colonies and report CFU per volume

See all count plates in the Microbiology Catalogue →

Ordering information

Product COLO code Pack
Rapid Aerobic Count Plate for Membrane Filtration PRO7376 20 plates

Product notice: preparation, storage conditions and shelf life are given on the label. Technical data on this page are for orientation; the label and the lot documentation apply. B2B prices are quoted net, excluding VAT.

Sales and technical support

COLO LabExperts

Polje ob Sotli 4, SI-3255, Slovenia

Phone / Viber / WhatsApp: +386 70 713 437
Email: sales@colo.si
Web: colo.si

Quotations and technical support for culture media and microbiology products across our international sales territory. B2B prices are net, excluding VAT.

COLO.SCIENCE | MICROBIOLOGY SUPPORT

Need the complete set for your method?

Send the sample type, target organism and the standard you follow. COLO.Science will put together the media, supplements, QC strains and confirmation tests for the whole procedure.

SKU: PRO7376 Categories: ,

Request a Quote