Two Shops
One Shipment

VIKING-ISE400 Benchtop pH/Ion Meter


COLO.Science · Benchtop pH/Ion Meter

pH ±0.002 pH · pX ±0.002 pX · ISE ±0.3 % · Ion calibration up to 7 points · IP54

1.250,00€

COLO.Science — Electrochemistry · pH/ion meters

VIKING-ISE400 Benchtop pH/Ion Meter

VIKING-ISE400 is a high-accuracy benchtop pH / ion meter (±0.002 pH / pX, ion ±0.3 %) with up to 7-point ion calibration, GLP memory, USB and RS-232. It combines a 7.0″ backlit LCD, pH −2.000 to 20.000 (±0.002 pH), ion concentration from 1.000e-9 to 9.999e+9 (±0.3 %), ion calibration in up to 7 points, a 500-result memory (GLP), USB and RS-232 connectivity and IP54 protection.

Benchtop pH/Ion MeterpHmVpXIonTemperature7.0″ LCD±0.002 pHISE ±0.3 %GLPUSBIP54

Overview

Applications

  • Water and wastewater: fluoride, nitrate, ammonium and chloride in drinking and waste water.
  • Food and agriculture: sodium, potassium, calcium and nitrate in food, soil extracts and fertilisers.
  • Pharma and chemistry: ion content of raw materials, solutions and products.
  • Education and research: pH, mV and ion methods on one benchtop instrument.

Why VIKING-ISE400

  • Clear display: 7.0″ LCD with backlight with Reading / Stable / Locked prompts.
  • Ion methods: Direct reading; linear or polyline calibration fit.
  • Flexible units: mol/L, mmol/L, g/L, mg/L, µg/L, ppm, ppb.
  • Data traceability: 500 results per parameter with date, time and GLP records.

Technical specifications

Model VIKING-ISE400
SKU PRO4763
pH range −2.000 to 20.000 pH
pH resolution 0.001 pH
pH accuracy ±0.002 pH
pH calibration up to 5 points
pH buffer recognition NIST, DIN, GB, USA, MERCK, GOST
mV range −2000.00 to 2000.00 mV
mV accuracy ±0.1 mV or ±0.03 %
pX range −2.000 to 20.000 pX
pX accuracy ±0.002 pX
pX calibration up to 7 points
Ion range 1.000e-9 to 9.999e+9
Ion units mol/L, mmol/L, g/L, mg/L, µg/L, ppm, ppb
Ion resolution up to 4 significant digits
Ion accuracy ±0.3 %
Ion calibration up to 7 points
Ion methods Direct reading; linear or polyline calibration fit
Temperature range −10 to 135 °C / 14 to 275 °F
Temperature accuracy ±0.1 °C
Temperature compensation ATC / MTC
Reading modes AutoRead (fast / medium / slow), timed, continuous
Reading prompts Reading, Stable, Locked
Display 7.0″ LCD with backlight
Data memory 500 results per parameter, GLP
Inputs BNC (pH / ISE), banana (reference), 4-pin (temperature)
Outputs USB (PC), RS-232 (printer)
Auto power-off 1–60 min or off
Power supply Power adapter, DC 20 V
Protection IP54
Dimensions 242 × 195 × 68 mm
Weight approx. 900 g

COLO.SCIENCE VIDEO

VIKING-ISE400 operation video

Installation, settings, pH and ion calibration and measurement — step by step.

VIKING-ISE400 operation video (10:15). Open the video in a new window

ELECTRODES AND ACCESSORIES

Electrodes and accessories for the VIKING-ISE400 benchtop pH/ion meter

The VIKING-ISE400 is delivered without electrodes: combined ion-selective electrodes, the 3-in-1 pH electrode and the temperature probe are chosen per ion and connect to the BNC and 4-pin inputs. Standards and ISA solutions complete the set for each ion.

Magnetic stirrer JB-10 JB-10

JB-10

Magnetic stirrer JB-10

Stirrer with stand rod for homogeneous samples during ion measurement and addition methods.

Standard delivery

Electrode stand COLO-5 COLO-5

COLO-5

Electrode stand COLO-5

Flexible electrode arm with 360° rotation; holds the electrode above the beaker.

Standard delivery

Fluoride combined ISE PF-202-C PRO6237

PRO6237

Fluoride combined ISE PF-202-C

Fluoride (F⁻) ion-selective electrode with built-in reference, BNC (Q9).

Optional

3-in-1 pH composite electrode E-301-QC PRO4153

PRO4153

3-in-1 pH composite electrode E-301-QC

pH + reference + temperature in one body; Ag/AgCl, 0–14 pH, BNC (Q9) and 4-pin connector.

Optional

Temperature probe T-818-Q PRO6166

PRO6166

Temperature probe T-818-Q

316 stainless steel, Φ4×120 mm, −5…105 °C; 4-pin connector for automatic temperature compensation.

Optional

Fluoride ISE PF-2-01 PRO6240

PRO6240

Fluoride ISE PF-2-01

Fluoride (F⁻) ion-selective electrode, 5–45 °C; used with a separate reference electrode.

Optional

Reference electrode 217-01 (double junction) PRO6175

PRO6175

Reference electrode 217-01 (double junction)

Saturated double-junction calomel reference electrode, U-shape terminal.

Optional

Thermal printer 771000 PRO6998

PRO6998

Thermal printer 771000

Prints measurement and calibration records (GLP).

Optional

More electrodes and accessories

  • PRO6242 — Chloride (Cl⁻) ISE
  • PRO6249 — Nitrate (NO₃⁻) ISE
  • PRO7128 — Fluoride ISE standard 0.1 mol/L, 250 mL

Tell us your sample and we will confirm the right electrode for your VIKING-ISE400 benchtop pH/ion meter. Full electrode range: Electrochemistry catalogue →

Selection guidance

VIKING-ISE400 is chosen where ±0.002 pH / pX and up to 7-point ion calibration are needed, e.g. for low fluoride or sodium levels, with GLP records and printer output. COLO.Science helps you choose electrodes, standards and ISA solutions.

Configuration checklist

  • Ions: which ions and at what concentration (mg/L, ppm, mol/L).
  • Sample matrix: interferences decide between direct reading and addition methods.
  • Electrodes: combined ISE or half-cell with reference, plus pH / temperature.
  • Documentation: GLP records, USB export or printer.
  • Need more?: see VIKING-ISE500.

Sales and support for international customers

COLO Lab ExpertsPolje ob Sotli 4, SI-3255 Buče, Slovenia
Phone: +386 70 713 437 · Email: sales@colo.si · Web: colo.si
We supply laboratories across Europe directly and through partners. B2B prices are quoted net, excluding VAT.

Need help choosing the right VIKING-ISE400 benchtop pH/ion meter configuration?

Tell us the ions, the sample matrix and the expected concentration. COLO.Science will confirm the electrodes, ISA solutions, standards and the VIKING-ISE400 configuration for your laboratory.

SKU: PRO4763 Category:
Measurement Parameters

Conductivity

Instrument Type

Benchtop

Request a Quote