📊 Technical Specifications
Measurement ranges and performance
| Parameter | Specification |
| Dissolved oxygen range | 0.00 to 20.00 ppm |
| DO resolution | 0.01 mg/L |
| DO accuracy | ±0.3 ppm |
| DO saturation range | 0.0 to 200.0% |
| DO saturation resolution | 0.10% |
| DO saturation accuracy | ±10.0% |
| Temperature range | 0 to 50°C |
| Temperature resolution | 0.1 |
| Temperature accuracy | ±0.2 relative |
| Sensor type | Optical dissolved oxygen sensor |
| Calibration | Air-saturated water or zero point |
| Pressure compensation | Automatic / manual barometric pressure compensation |
| Pressure units | kPa / mbar / Torr / Atm |
| Salinity correction | Manual salinity factor correction |
Measurement and reading modes
| Function | Technical note |
| Auto-Read | Fast / Medium / Slow reading stability options. |
| Timed Read | Timed reading mode for scheduled measurement intervals. |
| Continuous Read | Continuous measurement display for real-time monitoring. |
| Reading prompts | Reading / Stable / Locked prompts. |
| Endpoint capture | Auto-Hold function for endpoint detection and locking. |
System, data and connectivity
| Parameter | Specification |
| Display | 4.3″ color high-contrast LCD touchscreen with backlight. |
| Menu management | User, calibration, electrode, method and data management. |
| Data capacity | 1000 data groups. |
| GLP support | GLP-compliant data storage with review / compare / recalculate tools. |
| Optical DO probe input | 6-pin aviation connector. |
| Output / connectivity | USB 2.0. |
| Auto shutdown | 300 / 600 / 1200 / 1800 / 3600 seconds, or off. |
| Power supply | Rechargeable Li battery; AC adapter 100–240 V AC input, 5 V DC output. |
| Protection rating | IP65 waterproof housing. |
| Dimensions | 90 × 255 × 40 mm. |
| Weight | Approx. 500 g / 1.1 lb. |
| Product page | Open VIKING-DO511 product page |
| PDF catalog | Open VIKING-DO511 PDF |
Specification note
Probe selection: final configuration should match the sample matrix, cable length and required field or laboratory workflow.
Compensation: pressure and salinity settings should be checked for the measurement location and sample conditions.
Field use: carrying case, protective case, rechargeable battery and IP65 housing support portable measurement workflows.
Technical values are provided for product selection and orientation. Final delivered configuration, probe type, accessory set and documentation should be confirmed through the official COLO.Science quotation or manufacturer-confirmed offer.
Page 3 / 5
COLO.Science · Final Support Page
COLO.Science · VIKING-DO511 touch screen portable dissolved oxygen meter support
Need help selecting the correct portable DO meter configuration?
Send the sample matrix, measurement range, salinity and pressure conditions, required reporting format and expected field or laboratory use.
COLO.Science can help confirm whether VIKING-DO511 is the correct configuration for your water quality, environmental or QA/QC workflow.
Technical and commercial configuration disclaimer:
This technical specification is provided for orientation, product selection and general information only. It does not represent the final binding technical specification, delivered configuration, accessory set, procurement requirement or acceptance criterion for a specific unit. The final official technical specification is only the specification confirmed by the manufacturer and issued for the exact configuration through an official COLO.Science quotation, proforma invoice, contract document, order confirmation or manufacturer-approved technical offer. Any values, options, accessories or configurations shown in this document must be verified for the specific delivery and should not be used as an exclusion or elimination criterion in procurement procedures without written manufacturer confirmation.