COLO.Science — LABORATORY BALANCES — CENKA-6200
CENKA-6200 Precision Balance 6200 g / 0.01 g
CENKA-6200 precision balance is an advanced single-range laboratory balance for high-capacity precision weighing up to 6200 g with 0.01 g readability. It combines a Super Monoblock sensor, intelligent internal calibration, HD color touch display and RS-232 / USB connectivity. The CENKA-6200 precision balance is suitable for laboratory weighing, quality control, formulation, parts counting, density determination and industrial sample preparation where stable weighing, clear operation and documented results are required.
| Overview | Video Soon | Quote |
COLO.SCIENCE — ADVANCED LABORATORY PRECISION BALANCES
Single-range precision balance for higher-capacity laboratory weighing
The CENKA-6200 precision balance provides a single 6200 g weighing range with 0.01 g readability. Unlike the dual-range CENKA models, CENKA-6200 is intended for users who need the full capacity range with 10 mg readability in one configuration.
With Super Monoblock sensor technology, intelligent internal calibration, real-time temperature compensation, adjustable anti-vibration filtering and a large 168 × 190 mm pan, CENKA-6200 is suitable for laboratories that need dependable performance, larger sample capacity and flexible weighing modes in one instrument.
Key features
- CENKA-6200 precision balance with 6200 g single-range capacity.
- 0.01 g readability across the 6200 g weighing range.
- Super Monoblock sensor for fast response and stable weighing performance.
- Dual intelligent internal calibration with one-key, time, temperature and power-on routines.
- HD color touch display with real-time capacity bar, date, time and temperature.
- RS-232 and USB connectivity with direct PC readout.
Suitable for
- Laboratory weighing and sample preparation.
- Quality control in food, chemical, pharmaceutical and industrial laboratories.
- Parts counting, percentage weighing and formulation workflows.
- Density determination with optional density kit.
- Production control with Hi-Lo limits, peak hold and accumulation functions.
- Routine verification with optional OIML M1 control weights.
TECHNICAL SPECIFICATIONS — CENKA-6200 PRECISION BALANCE
| Model | CENKA-6200 |
| SKU | PRO5318 |
| Product type | Advanced laboratory precision balance with single-range 6200 g capacity |
| Capacity range | 6200 g |
| Readability | 10 mg · 0.01 g |
| Repeatability | Not stated in current specification |
| Linearity | ±30 mg |
| Range type | Single range |
| Measuring sensor | Super Monoblock sensor |
| Calibration system | Dual intelligent automatic internal calibration |
| Calibration triggers | One-key, time, temperature and power-on calibration |
| Temperature compensation | Real-time temperature compensation |
| Response time | 2–5 s |
| Vibration filtering | Seven levels, adjustable stabilization time |
| Display | HD color touch display with capacity bar |
| Pan dimensions | 168 × 190 mm |
| Housing dimensions | 345 × 223 × 110 mm |
| Weighing units | 20+ units including g, mg and ct; 2 custom units |
| Operating modes | Percentage, density, dynamic weighing, counting, price computing |
| Control modes | Hi-Lo limits, Gross/Net/Tare, peak hold, accumulation |
| Connectivity | RS-232 and USB, direct PC readout |
| Underhook | Supported |
| Draft protection | Anti-static draft shield with metal back |
Final weighing performance depends on installation conditions, vibration, air movement, leveling, warm-up, calibration settings, sample handling and laboratory SOP. The official quotation defines the delivered configuration, optional accessories and verification package.
Internal calibration, weighing modes and data output
Intelligent internal calibration
CENKA-6200 includes internal calibration routines for one-key calibration, timed calibration, temperature-triggered calibration and power-on calibration. This reduces dependence on external adjustment weights during routine operation.
Flexible weighing functions
Percentage weighing, parts counting, dynamic weighing, price computing, density mode, Hi-Lo control, peak hold and accumulation support laboratory and production weighing workflows.
Connectivity and documentation
RS-232 and USB interfaces allow direct PC readout and connection to compatible printer options, supporting routine data recording, QC documentation and structured weighing reports.
COLO.SCIENCE VIDEO
CENKA-6200 video presentation is in preparation
The video will present single-range precision weighing, internal calibration, touchscreen operation, basic weighing modes, printer / PC connection and routine verification with optional control weights.
COLO.SCIENCE KNOWLEDGE
Learn more about laboratory balances and weighing workflows
Explore COLO.Science resources covering laboratory weighing, balance selection, calibration, control weights, sample preparation and weighing documentation.
Applications and laboratory value
Laboratory sample preparation
The CENKA-6200 precision balance supports routine weighing of powders, reagents, samples and containers where 0.01 g readability is required up to 6200 g.
Quality control
Hi-Lo limits, accumulation, peak hold and direct data output make CENKA-6200 practical for QC laboratories and production-related weighing checks.
Counting and formulation
Parts counting, percentage weighing, Gross/Net/Tare and formulation-style workflows help users handle repeated measurements and structured weighing tasks.
Density and documentation
With optional density kit, printer options and RS-232 / USB connection, the balance can be configured for documented weighing workflows and routine verification.
How to choose the correct CENKA balance configuration
When selecting the CENKA-6200 precision balance, define the expected sample mass, tare mass, required readability, verification frequency and documentation workflow. CENKA-6200 is the single-range model in the CENKA series, intended for users who need 0.01 g readability up to 6200 g.
COLO.Science can help define the appropriate control weight, certificate, printer, density kit and PC connection requirements so that the delivered CENKA-6200 configuration matches the laboratory method and purchasing documentation.
CENKA-6200 precision balance for stable 6200 g laboratory weighing
The CENKA-6200 precision balance is designed for laboratories that need 0.01 g readability with higher single-range capacity. It is useful when users want to avoid switching between fine and extended ranges and require one clear weighing range for larger laboratory samples.
Its internal calibration, touchscreen display, anti-vibration filtering and data connectivity make CENKA-6200 a strong choice for laboratory weighing, industrial QC, teaching laboratories and production support areas. For best results, the balance should be installed on a stable surface, protected from drafts and vibration, leveled correctly and verified according to the laboratory SOP.
Configuration notice
CENKA balances may be delivered in different configurations depending on selected accessories, printer, density kit, verification weights, certificates and communication requirements. Internal calibration is used for the balance calibration cycle, while optional control weights are recommended for independent routine checks according to the laboratory SOP. The current specification does not state repeatability for CENKA-6200, so final acceptance criteria should be confirmed in the quotation. The official quotation defines the final scope of supply. Website content is provided for general product presentation and may not represent the exact delivered configuration. Specifications may change without notice.