COLO.SCIENCE – NICHIPET AIR
1–10 mL variable micropipette Nichipet Air (single-channel)
The Nichipet Air 1–10 mL variable micropipette is an original Nichiryo instrument made in Japan. It is among the world’s lightest micropipettes, with up to 70 % less stroke load – made for long pipetting series.
Volume is set from 1–10 mL in 10 µL increments. Accuracy and precision below are Nichiryo values measured with original Nichiryo tips.
Same range, 4 Nichiryo lines – choose by your work
All lines below cover 1–10 mL, are made in Japan and use original Nichiryo tips. They differ in weight, resistance and durability – pick the line that fits how often and with what liquids you pipette.
Nichipet AirAmong the world’s lightest pipettes – for long series.Other Nichipet Air models: 0.1–2 µL · 0.5–10 µL · 2–20 µL · 10–100 µL · 20–200 µL · 100–1000 µL · 0.5/1–5 mL
Key features
- Among the world’s lightest micropipettes – approx. 70 g
- Up to 70 % less stroke load than conventional models
- Entire body autoclavable at 121 °C for 20 minutes
- Volume setting independent of the push button – no volume shift while pipetting
- Removable tip ejector, also for thin test tubes
Where 1–10 mL precision matters
- Media and buffer preparation in larger volumes
- Filling of tubes and flasks
- Volumetric work where a measuring pipette would be slow
Tips for this pipette (1–10 mL)
Recommended Nichiryo Premium tips for Nichipet Air 1–10 mL.
| Tip | Packing | Quantity | Sterility | COLO code |
|---|---|---|---|---|
Premium tip ZS 1–10 mL |
Bulk bag | 200 pcs | non-sterile | PRO4886 |
Premium tip ZS 1–10 mL |
Rack | 80 pcs (2 × 40) | non-sterile | PRO4892 |
Premium tip ZS 1–10 mL |
Rack | 80 pcs (2 × 40) | sterile | PRO4885 |
According to Nichiryo, any Nichiryo tip can be used with this pipette as long as the volume matches. Nichiryo tests every pipette before shipment with Premium tips, the recommended tips for accuracy.
Accessories
Carousel stand (8 pipettes)For Air (also multichannel), Premium, Premium LT and LeTechnical specifications
| Volume range | 1–10 mL |
|---|---|
| Increment | 10 µL |
| Channels | Single-channel |
| Compatible Nichiryo tips | Premium tip ZS (bulk, rack, sterile rack) |
| Origin | Nichiryo, Japan |
Accuracy and precision
| Volume (µL) | Accuracy (%) | Precision CV (%) |
|---|---|---|
| 1000 | ±2 | ≤0.6 |
| 5000 | ±0.8 | ≤0.2 |
| 10000 | ±0.5 | ≤0.15 |
* According to Nichiryo test conditions with original Nichiryo tips. Values at the lowest volume depend strongly on operator skill and conditions.