COLO.Science · Portable Conductivity Meter

EC 0.000 µS/cm…3000 mS/cm · ±0.5 % FS · Resistivity to 100.0 MΩ·cm · Calibration 1–5 points · IP67

850,00€

COLO.Science — Electrochemistry · conductivity meters

VIKING-EC510 Portable Conductivity Meter

VIKING-EC510 is a research-grade portable touchscreen conductivity meter with measurement up to 3000 mS/cm, ±0.5 % FS accuracy, up to 5-point calibration, method management, USB 2.0, Bluetooth and IP67 protection. It combines a 4.3″ colour touchscreen, conductivity measurement from 0.000 µS/cm to 3000 mS/cm (±0.5 % FS), 1- to 5-point calibration with automatic standard recognition, automatic / manual temperature compensation, a 1000-result memory (GLP), USB and Bluetooth connectivity, a rechargeable Li battery and IP67 protection.

Portable conductivity meterECResistivityTDSSalinity4.3″ touchscreen±0.5 % FSCalibration 1–5 pointsGLPUSBIP67

Overview

Applications

  • Water quality: drinking water, wastewater, surface and process water.
  • Purified water: resistivity and conductivity of deionised, RO and laboratory water.
  • Field and on-site: compact IP67 housing for sampling points, rivers, wells and plants.
  • Food, aquaculture and industry: salinity, TDS and conductivity of brines, rinse water and process solutions.

Why VIKING-EC510

  • Clear display: 4.3″ colour touchscreen with guided menus for measurement, calibration and data.
  • Calibration: 1–5 points with automatic recognition of 10 / 84 / 500 / 1413 µS/cm, 12.88 mS/cm.
  • Portable protection: IP67 housing, silicone case and wristband for one-hand work.
  • Data traceability: 1000 results stored per parameter with date, time and GLP records.

Technical specifications

Model VIKING-EC510
SKU PRO6088
Conductivity range 0.000 µS/cm to 3000 mS/cm
Conductivity resolution 0.001 µS/cm minimum, auto range
Conductivity accuracy ±0.5 % FS
Reference temperature 5 / 10 / 15 / 18 / 20 / 25 °C
Calibration 1–5 points, standard recognition, calibration reminder
Recognised standards 10 / 84 / 500 / 1413 µS/cm, 12.88 mS/cm; 146.5 / 1408 µS/cm, 12.85 / 111.3 mS/cm
Settable parameters Cell constant, temperature coefficient, TDS factor
Compensation type None, linear, pure water
Resistivity range 5.00 Ω·cm to 100.0 MΩ·cm
Resistivity accuracy ±0.5 % FS
TDS range 0.000 ppm to 1000 ppt
TDS accuracy ±0.5 % FS
Salinity (NaCl) 0.0 to 80.0 ppt, 0.1 ppt, ±1 ppt
Temperature range −10 to 135 °C / 14 to 275 °F
Temperature accuracy ±0.1 °C
Temperature compensation ATC / MTC
Reading modes AutoRead (fast / medium / slow), timed, continuous
Reading prompts Reading, Stable, Locked
Display 4.3″ colour touchscreen
Data memory 1000 results per parameter, GLP
Management Users, calibration, electrodes, methods, data analysis
Electrode input 5-pin connector (conductivity + temperature)
Outputs USB 2.0 (flash drive, PC, scanner), Bluetooth
Auto power-off 300 / 600 / 1200 / 1800 / 3600 s or off
Power supply Rechargeable Li battery; adapter 100–240 V AC / 5 V DC
Protection IP67
Dimensions 90 × 255 × 40 mm
Weight approx. 500 g

COLO.SCIENCE VIDEO

VIKING-EC510 operation video

Installation, settings, cell constant calibration and measurement — step by step.

VIKING-EC510 operation video (5:33). Open the video in a new window

ELECTRODES AND ACCESSORIES

Electrodes and accessories for the VIKING-EC510 portable conductivity meter

The VIKING-EC510 is delivered with the conductivity electrode DJS-1VTC (k = 1, ATC, 5-pin connector), the 1413 µS/cm standard and electrode holder, silicone case, wristband, touch pen, carrying case. Electrodes with k = 0.1, 0.01 and 10 and standards from 84 µS/cm to 111.3 mS/cm extend the range from ultrapure water to brines.

VIKING-EC510T handheld conductivity meter

PRO6154

Conductivity electrode DJS-1VTC (k = 1, ATC)

2–20000 µS/cm, glass body, with temperature sensor, 0–80 °C, Φ12×120 mm; 5-pin connector.

Standard delivery

Conductivity standard 1413 µS/cm, 50 mL PRO7007

PRO7007

Conductivity standard 1413 µS/cm, 50 mL

Calibration standard at 25 °C for cell-constant calibration.

Standard delivery

Silicone protective case and wristband —

—

Silicone protective case and wristband

Shock-absorbing silicone sleeve and wristband for safe one-hand field use.

Standard delivery

Carrying case PRO7006

PRO7006

Carrying case

Protective case for the meter, electrode and buffers in field use.

Standard delivery

Conductivity electrode DJS-1VTG (k = 1, ATC) PRO6156

PRO6156

Conductivity electrode DJS-1VTG (k = 1, ATC)

2–3000 µS/cm, glass body, with temperature sensor, 0–80 °C, Φ12×120 mm; 5-pin connector.

Optional

Conductivity electrode DJS-0.1VTG (k = 0.1, ATC) PRO6157

PRO6157

Conductivity electrode DJS-0.1VTG (k = 0.1, ATC)

0.05–200 µS/cm, glass body, with temperature sensor, 0–80 °C, Φ12×120 mm; 5-pin connector.

Optional

Conductivity electrode DJS-0.01VT (k = 0.01, ATC) PRO6158

PRO6158

Conductivity electrode DJS-0.01VT (k = 0.01, ATC)

0.05–20 µS/cm, titanium alloy, with temperature sensor, 0–60 °C, Φ18×50 mm; 5-pin connector.

Optional

Conductivity electrode DJS-10VTC (k = 10, ATC) PRO6160

PRO6160

Conductivity electrode DJS-10VTC (k = 10, ATC)

2000–200000 µS/cm, glass body, with temperature sensor, 0–80 °C, Φ12×120 mm; 5-pin connector.

Optional

More electrodes and accessories

  • PRO6159 — Conductivity electrode DJS-0.01VT (k = 0.01, ATC), flow cell
  • PRO6130 — Conductivity standard 1413 µS/cm, 250 mL
  • PRO6132 — Conductivity standard 84 µS/cm, 250 mL
  • PRO6131 — Conductivity standard 146.5 µS/cm, 250 mL

Tell us your sample and we will confirm the right electrode for your VIKING-EC510 portable conductivity meter. Full electrode range: Electrochemistry catalogue →

Selection guidance

VIKING-EC510 brings benchtop-class performance to the field: 3000 mS/cm range, ±0.5 % FS, method management, Bluetooth and IP67 — with carrying case included. COLO.Science helps you choose the electrode and standards.

Configuration checklist

  • Sample type: drinking, waste, pure or process water, solutions, brines.
  • Range: expected conductivity decides the cell constant (k = 0.01 / 0.1 / 1 / 10).
  • Calibration: number of points and standards close to the sample value.
  • Documentation: memory, GLP records, USB export or printer.
  • Need more?: see VIKING-EC500.

Sales and support for international customers

COLO Lab ExpertsPolje ob Sotli 4, SI-3255 Buče, Slovenia
Phone: +386 70 713 437 · Email: sales@colo.si · Web: colo.si
We supply laboratories across Europe directly and through partners. B2B prices are quoted net, excluding VAT.

Need help choosing the right VIKING-EC510 portable conductivity meter configuration?

Tell us the sample type, conductivity range and how you document results. COLO.Science will confirm the electrode, standards and VIKING-EC510 configuration for your workflow.

Selection, commissioning and service support

Choosing a laboratory instrument is easier when the application is clear from the start. Tell us what kind of samples you measure, how many per day, which range and accuracy you need and which standards or internal procedures you follow. Based on that, our team recommends a suitable configuration together with the accessories and consumables that make sense for routine work, so you do not pay for options you will never use.

After delivery we stay available for practical questions: first start-up, calibration routine, daily care, storage and typical operator mistakes that shorten the life of sensors and wearing parts. If results begin to drift or the device reports an error, describe the symptoms and we will suggest what to check first before any repair is considered.

Spare parts, replacement sensors and calibration materials can be ordered later through the same contact. For a quotation or technical advice, use the request button on this page and add a short description of your application.

SKU: PRO6088 Category: Tag:
Measurement Parameters

Conductivity

Instrument Type

Benchtop

Request a Quote