COLO.Science · Technical Specification
VIKING-M310
Portable pH / Conductivity / ISE / DO Multi-parameter Water Analyzer
VIKING-M310 Portable Multi-parameter Water Analyzer is a field-ready electrochemistry instrument for pH, mV, pX, ISE, conductivity, resistivity, TDS, salinity, dissolved oxygen and temperature. The instrument combines a 4.3″ touchscreen, IP65 portable housing, GLP-oriented data memory, USB output and automatic or manual temperature compensation for laboratory, plant and field water quality workflows.
Portable analyzerpH / mVpX / ISEEC conductivityTDS / salinityResistivityDO oxygenTemperature4.3″ touchscreenGLP 1000 groupsUSBIP65
Document type: Technical Specification Sheet
Product family: Portable Electrochemistry / Water Quality Multi-parameter Analyzer
Model: VIKING-M310 · SKU: TBC
Product page: colo.si/product/viking-m310-portable-multi-parameter-meter/
Format: A4 landscape · COLO.Science TechSpec v2.4 with navigation links
VIKING-M310 portable multi-parameter water analyzer main unit
VIKING-M310 · portable pH / EC / ISE / DO water analyzer · main unit
Model / SKUVIKING-M310
TBC
Address / HQPolje ob Sotli 4
SI-3255, Slovenia
Page 1 / 5
COLO.Science logoVIKING-M310 · Portable Multi-parameter Water Analyzer
Technical data sheet · Informational document · Controlled electronic document
Product page: VIKING-M310 on colo.si
VIKING-M310 · technical specificationPortable multi-parameter analyzer for pH, mV, pX, ISE, EC, TDS, salinity, resistivity, DO and temperature
pH -2.00 to 20.00ISE 1.000e-9 to 9.999e+9EC 0.000 μS/cm to 1000 mS/cmDO 0.00 to 50.00 mg/L— Compact field workflow for water quality laboratories and on-site testing
📋 Product Overview
Application profile
Water quality: designed for pH, conductivity, TDS, salinity, ISE, dissolved oxygen and temperature checks in water and process samples.
Field and laboratory use: portable IP65 unit with 4.3″ touchscreen, rechargeable battery and carrying case workflow.
Multi-parameter testing: combines electrochemical and dissolved oxygen measurement functions in one compact instrument.
Routine QA/QC: suitable for environmental monitoring, plant checks, aquaculture, wastewater control and routine laboratory measurements.
Design and handling advantage
Touchscreen workflow: 4.3″ LCD touchscreen with backlight for direct method and calibration navigation.
Reading modes: Auto-Read Fast / Medium / Slow, Timed Read and Continuous Read modes.
Traceability: GLP-oriented memory for up to 1000 groups per parameter.
Connectivity: USB output for PC or printer workflows.
Key features
Parameters: pH, mV, pX, ISE, conductivity, resistivity, TDS, salinity, dissolved oxygen and temperature.
pH performance: -2.00 to 20.00 pH range, 0.1 / 0.01 pH resolution and ±0.01 pH accuracy.
Conductivity performance: 0.000 μS/cm to 1000 mS/cm range with ±1.0% FS accuracy.
DO workflow: polarographic DO electrode, concentration and saturation display, auto barometric compensation and manual salinity correction.
Portable protection: IP65 housing for field work and daily mobile use.
Core technical summary
ParameterSpecification
ModelVIKING-M310
SKUTBC
Instrument typePortable pH / conductivity / ISE / DO multi-parameter water analyzer
Measured parameterspH, mV, pX, ISE, EC, resistivity, TDS, salinity, DO concentration, DO saturation, temperature
Display4.3″ LCD touchscreen with backlight
Data storage1000 groups; GLP features supported
InputspH BNC Q9; DO+Temp 4-pin; Conductivity+Temp 5-pin aviation
ProtectionIP65 portable unit
pH accuracy±0.01 pH
EC range0.000 μS/cm–1000 mS/cm
DO range0.00–50.00 mg/L
ProtectionIP65
Page 2 / 5
📊 pH / mV / pX / ISE Specifications
pH, mV and pX measurement
ParameterRange / resolution / accuracyCalibration / notes
pH range-2.00 to 20.00 pHUp to 5-point calibration
pH resolution0.1 / 0.01 pHSelectable according to workflow
pH accuracy±0.01 pHElectrode diagnostics: slope and offset
pH standardsNIST, GB, USA, DINAutomatic buffer recognition
mV range-2000.0 to 2000.0 mVFor ORP and millivolt measurement
mV resolution0.1 mVRelative mV workflows depending on method
mV accuracy±0.3 mV or ±0.1%According to instrument specification
pX range-2.00 to 20.00 pXUp to 5-point calibration
pX resolution0.1 / 0.01 pXFor ion-selective workflows
pX accuracy±0.01 pXMethod-dependent performance
Reading and temperature workflow
FunctionTechnical note
Reading modesAuto-Read Fast / Medium / Slow, Timed Read and Continuous Read.
CompensationATC / MTC supported for stable routine measurements.
Conductivity TCTemperature compensation types: none, linear or pure water.
Data handlingGLP-oriented storage for 1000 groups with USB output for PC / printer.
ISE concentration measurement
ParameterSpecificationNotes
ISE range1.000e-9 to 9.999e+9Concentration measurement by selected ion method
ISE unitsmol/L, mmol/L, g/L, mg/L, μg/L, ppm, ppbSelectable concentration units
ISE accuracy±0.5%Method and electrode dependent
ISE calibrationUp to 5 pointsSupports routine calibration curves
ISE methodsDirect, Standard Addition, Sample Addition, GRANBuilt-in ion measurement workflows
VIKING-M310 touchscreen display workflow
4.3″ touchscreen display · method navigation, calibration and measurement control
pH calibrationUp to 5 points
ISE calibrationUp to 5 points
Reading modesAuto / Timed / Continuous
Technical values are provided for product selection and orientation. Final electrode type, calibration method, ISE method and accessory configuration should be confirmed through the official COLO.Science quotation or manufacturer-confirmed offer.
Page 3 / 5
⚙️ Conductivity / Resistivity / TDS / Salinity / DO / System Specifications
Conductivity-related parameters
ParameterRange / resolution / accuracyCalibration / notes
Conductivity0.000 μS/cm to 1000 mS/cmUp to 3-point calibration
EC accuracy±1.0% FSFull-scale accuracy
Reference temperature20 / 25 °CSelectable reference temperature
EC standards84 μS/cm, 1413 μS/cm, 12.88 mS/cm
Resistivity5.00 Ω·cm to 20.00 MΩ·cmAccuracy ±1.0% FS
TDS0.00 ppm to 300 pptResolution min. 0.01 mg/L; accuracy ±1.0% FS
Salinity0.0 to 80.0 pptResolution 0.1 ppt; accuracy ±2 ppt
System and physical data
ParameterSpecification
Display4.3″ LCD touchscreen with backlight
Auto shutdown300–3600 s or Off
Date / timeSupported
OutputsUSB for PC / printer
PowerRechargeable Li battery; AC 100–240 V input, DC 5 V output
Dimensions / weight90 × 255 × 40 mm; 500 g (1.1 lb)
Carton490 × 410 × 220 mm; gross weight 5.5 kg
Dissolved oxygen measurement
ParameterSpecificationNotes
Sensor typePolarographic DO electrodeDelivered depending on selected configuration
DO concentration0.00 to 50.00 mg/LResolution 0.01 mg/L
DO accuracy±0.10 mg/LWithin specified concentration range
DO saturation0.0 to 300.0%Resolution 0.10%; accuracy ±2.0%
DO calibrationAir-saturated or zero oxygenRoutine DO workflow
Barometric compensationAutomaticFor DO measurement
Salinity correctionManualFor sample-specific correction
Temperature-5 to 110 °C / 23 to 230 °FResolution 0.1; accuracy ±0.2 °C
VIKING-M310 connector types pH BNC DO and conductivity aviation connectors
Connector types · pH BNC Q9, DO+Temp 4-pin and Cond.+Temp 5-pin aviation interfaces
COLO.Science logo Configuration / Contact / Disclaimer
Standard packing and final quotation notes continue on Page 5
Page 4 / 5
📦 Standard Packing / Kit Configuration
VIKING-M310 carrying case standard packing
Carrying case and standard packing for portable multi-parameter workflow
Typical included items
Electrodes: 3-in-1 pH composite electrode, conductivity electrode and polarographic DO electrode.
Standards: NIST pH buffers 4.01, 7.00, 10.01, each 50 mL; 1413 μS/cm EC standard solution, 50 mL.
Accessories: electrode holder, silicone rubber case, wrist straps and carrying case.
Final scope: delivered configuration should be confirmed in the official quotation before order confirmation.
Why VIKING-M310
All-in-one portability: pH / EC / ISE / DO / temperature in one mobile instrument.
GLP traceability: 1000-group memory and documentation-oriented workflow.
Field-ready design: IP65 housing, rechargeable battery and carrying case.
Fast routine workflow: Auto-Read, Timed Read and Continuous Read modes.
Configuration notice

Portable multi-parameter analyzers may be delivered in different configurations depending on selected pH, conductivity, ISE, ORP and dissolved oxygen electrodes, calibration standards, carrying case and accessories. The official quotation defines the final scope of supply.

COLO.Science technical and sales support
Need a VIKING-M310 configuration?
Contact COLO.Science for product selection, electrode compatibility, dissolved oxygen workflow, calibration standards, accessories, documentation and quotation support.
Contact
🌐 colo.si
📍 Polje ob Sotli 4, SI-3255, Slovenia
COLO.Science · Water Quality / Electrochemistry

Portable multi-parameter analyzer for pH, EC, ISE, DO and field water quality testing

Use this document for preliminary product selection. For tenders, formal procurement and confirmed technical comparison, request an official manufacturer-verified quotation and configuration confirmation.

COLO.Science · Technical specification sheet · VIKING-M310 · Portable Multi-parameter Water Analyzer
Disclaimer: This technical specification sheet is prepared for informational and product-selection purposes. Technical characteristics, included accessories and configuration may vary by supplier confirmation, application requirements, manufacturer revision and official quotation. Only a manufacturer-confirmed offer or COLO.Science official quotation should be treated as the binding technical and commercial reference for procurement, tenders or contractual supply.
Page 5 / 5