COLO.Science · Technical Specification

VIKING-EC510

Portable Conductivity Meter · EC / TDS / Salinity / Resistivity / Temperature
Model: VIKING-EC510
Product family: Portable conductivity meters
Protection: IP65
Format: A4 landscape · EN

VIKING-EC510 is a rugged portable conductivity meter for measurement of conductivity, TDS, salinity, resistivity and temperature in laboratory and field workflows.

The instrument combines a 4.3-inch high-contrast color touchscreen, intelligent operating system, GLP storage, USB 2.0 communication, up to 5-point calibration and IP65 protection for routine water quality analysis.

0.000 µS/cm – 3000 mS/cm ±0.5% FS 1–5 point calibration GLP 1000 groups USB 2.0 ATC / MTC IP65 Rechargeable battery
Parameter coverageEC, TDS, salinity, resistivity and temperature in one portable meter.
Field-ready housingIP65 protection, rugged handling and transport case support field applications.
Traceability1000 GLP data groups with date/time support and USB 2.0 communication.
COLO.Science VIKING-EC510 portable conductivity meter main unit
COLO.Science · Portable Water Quality Meter

Key features and supplied configuration

VIKING-EC510 · field and laboratory conductivity workflows
Portable multi-parameter conductivity platform: VIKING-EC510 is designed for users who need EC, TDS, salinity, resistivity and temperature measurement with touchscreen control, GLP data handling and rugged IP65 field usability.

Key instrument features

  • 4.3-inch high-contrast color LCD touchscreen.
  • Intelligent operating system for user, calibration, electrode, method, data and log management.
  • Measurement parameters: conductivity, resistivity, TDS, salinity and temperature.
  • Multiple reading modes: Auto-Read, Timed-Read and Continuous-Read.
  • Auto-Read supports Fast / Medium / Slow measurement behaviour.
  • Automatic and manual temperature compensation: ATC / MTC.
  • Temperature compensation types: none, linear and pure water.
  • Up to 5-point calibration with automatic standard recognition.
  • Settable cell constant, reference temperature, temperature coefficient and TDS factor.
  • GLP-compliant memory: 1000 data groups with date/time support.
  • On-meter data review, comparison and recalculation.
  • USB 2.0 communication for flash drive, PC and scanner workflows.
  • Rechargeable lithium battery and auto power-off options.
  • IP65 waterproof and dust-tight protection.

Included accessories

DJS-1VTC
EC / temperature combination electrode
1413 µS/cm
EC standard solution, 50 mL, 1 vial
Electrode holder
For laboratory operation
Silicone rubber case
Protection and improved grip
Wrist strap and touch pen
Field-use accessories
Carrying case
Transport and storage
COLO.Science VIKING portable meter carrying case with standards
Carrying case with standards and field-ready accessory layout. Exact supplied configuration should be confirmed in the approved quotation.
COLO.Science · Measurement Performance

Technical specifications

VIKING-EC510 · EC / TDS / Salinity / Resistivity / Temperature
Conductivity, resistivity and TDS
ModelVIKING-EC510
Instrument typePortable EC / TDS / salinity / resistivity / temperature meter
Conductivity range0.000 µS/cm – 3000 mS/cm
Conductivity resolution0.001 µS/cm minimum, varies with range
Conductivity accuracy±0.5% FS
Resistivity range5.00 Ω·cm – 100.0 MΩ·cm
Resistivity resolution0.01 Ω·cm minimum
Resistivity accuracy±0.5% FS
TDS range0.000 ppm – 1000 ppt
TDS resolution0.001 mg/L minimum, range-dependent
TDS accuracy±0.5% FS
Salinity and temperature
Salinity range0.0 – 80.0 ppt
Salinity resolution0.1 ppt
Salinity accuracy±1 ppt
Temperature range−10 – 135 °C / 14 – 275 °F
Temperature resolution0.1 °C
Temperature accuracy±0.1 °C
Temperature compensationATC / MTC
Compensation typesNone / linear / pure water
Reference temperature5 / 10 / 15 / 18 / 20 / 25 °C, settable
Settable method factorsCell constant, temperature coefficient, TDS factor
Calibration and data management
Calibration1–5 points with automatic standard recognition
Reading modesAuto-Read, Timed-Read, Continuous-Read
Auto-Read modesFast / Medium / Slow
Endpoint functionAuto-Hold endpoint sensing and lock
Status promptsReading / Stable / Locked
Data storage1000 groups with GLP and date/time support
Data analysisReview / compare / recalculate on meter
Display, connectivity and physical data
Display4.3-inch high-contrast color LCD touchscreen
ConnectivityUSB 2.0: flash drive, PC, scanner
IP ratingIP65 waterproof and dust-tight
PowerRechargeable lithium battery + AC adapter, 100–240 V input, DC 5 V output
Auto shutdown300 / 600 / 1200 / 1800 / 3600 s or off
Dimensions90 × 255 × 40 mm
Weight500 g / 1.1 lb
COLO.Science · Field Workflow

Portable workflow, accessories and connector layout

VIKING-EC510 · field operation and accessory context
COLO.Science VIKING-EC510 carrying case with standards and accessories
Carrying case with standards: VIKING portable meter configuration can be organised for routine field measurement, storage and transport. Included accessories and final configuration depend on approved quotation.
COLO.Science VIKING portable meter connectors detail
Connector detail: portable VIKING meter connector layout for sensor and temperature workflow reference. Verify final probe compatibility before quotation.

Field measurement

IP65 housing, rechargeable power and carrying case make VIKING-EC510 suitable for field water quality measurements and environmental monitoring.

Laboratory support

Touchscreen operation, calibration guidance and GLP records support daily laboratory EC/TDS/salinity workflows.

Process checks

Wide conductivity range, TDS and salinity coverage support industrial process water, wastewater and QC checks.

Configuration and compatibility notes

The VIKING-EC510 configuration should be selected according to sample matrix, expected conductivity range, electrode type, required calibration standards, temperature compensation method and documentation workflow.

For water quality monitoring, environmental field work and industrial process control, confirm probe compatibility, standard solutions, carrying case content and accessory list before final purchase or tender specification.

COLO.Science · Application Fit

Application guidance and selection notes

VIKING-EC510 · laboratory and field use

When VIKING-EC510 is a suitable choice

  • When EC, TDS, salinity, resistivity and temperature must be measured with one portable meter.
  • When field teams need rugged IP65 protection and a transportable case-based configuration.
  • When the laboratory needs GLP data storage, date/time support and USB 2.0 export.
  • When up to 5-point calibration and automatic standard recognition are required.
  • When touchscreen operation and guided data management improve daily workflow efficiency.

Method and configuration checks

  • Confirm conductivity range and sample matrix before final instrument selection.
  • Select the correct EC electrode and cell constant for the expected measurement range.
  • Choose calibration standards that match the operating range and laboratory SOP.
  • Define temperature compensation type: none, linear or pure water.
  • Review whether data export, GLP records, carrying case and field accessories are required.

Water quality labs

Routine monitoring of EC, TDS, salinity, resistivity and temperature for water quality control.

Environmental field work

Portable IP65 measurement for environmental monitoring, surface water checks and sample screening.

Industrial process control

Process water, wastewater, food and beverage, chemical and pharmaceutical QC workflows.

Measurement reliability: Conductivity readings depend on clean electrodes, correct cell constant, calibration standard condition, temperature compensation settings and sample matrix. VIKING-EC510 provides a robust portable platform, but method validation and calibration practice remain critical for dependable results.
COLO.Science · Links / Quotation / Notice

Product links, quotation support and technical notice

VIKING-EC510 · contact and disclaimer

Configure VIKING-EC510 for portable water quality measurement

COLO.Science can support selection of portable conductivity meters, EC electrodes, standards, carrying cases and accessories for water quality laboratories, environmental monitoring and industrial QC teams.

COLO.Science
Laboratory equipment, technical specifications and product configuration.
sales@colo.si
+386 64 222 724
https://colo.si/contacts/

Recommended document links

Video presentation · in preparation

A VIKING-EC510 product video can be added later. It should present touchscreen operation, EC calibration workflow, conductivity / TDS / salinity / resistivity measurement routines, carrying case configuration and USB data export.

Temporary video placeholder: #viking-ec510-video
Replace this anchor with the final YouTube / product video URL when available.

Technical disclaimer: This COLO.Science technical specification is prepared for product orientation, quotation preparation and preliminary comparison only. Technical characteristics, supplied accessories and configuration options may vary depending on the confirmed offer, manufacturer documentation and selected electrode configuration. Only the official quotation, order confirmation and manufacturer-approved specification should be treated as definitive for procurement, tender or contractual use.

Company: COLO Lab Experts, Polje ob Sotli 4, SI-3255 Slovenia · www.colo.si · sales@colo.si · +386 64 222 724