Digital Touch-Screen Rotational Viscometers | Up to 2,000,000 mPa.s | Automatic Spindle and Speed Guidance

VISCO900 digital rotational viscometers combine a 5-inch color touch screen, automatic scanning, real-time viscosity curves, Pt100 temperature measurement and programmable test methods. The series supports routine and advanced viscosity testing in paints, coatings, cosmetics, inks, food, oils, adhesives, latex and other laboratory or production applications.

5-inch touch screenUp to 2,000,000 mPa.sAuto scanPt100 standardRS23230 programsLive curvesOptional software
Document type: Technical Specification Sheet
Product family: VISCO Digital Rotational Viscometers
Models covered: VISCO500 / VISCO900E / VISCO900S
VISCO900 range: 1 to 2,000,000 mPa.s
Format: A4 landscape | COLO.Science TechSpec v2.4
VISCO900 digital touch-screen rotational viscometer main unit
VISCO900 main unit | 5-inch color touch screen | rotational viscosity measurement
Series range1-2,000,000
mPa.s
Address / HQPolje ob Sotli 4
SI-3255, Slovenia
Page 1 / 5
COLO.Science logoVISCO900 | Digital Rotational Viscometer Series
Technical data sheet | Informational document
Models: VISCO500 / VISCO900E / VISCO900S
VISCO900 | series overviewTouch-screen control, automatic range guidance and temperature-aware viscosity measurement
Dynamic viscosityKinematic viscosityShear dataTime and temperature curvesSelect model, spindle and speed according to the expected sample viscosity
Series Overview and Model Selection
Application profile
Coatings and inks: paints, coatings, printing inks, pigments and related formulations.
Food and cosmetics: creams, gels, sauces, oils, starch systems and process samples.
Adhesives and polymers: solvent adhesives, latex and other medium- or high-viscosity materials.
Research and QC: method programming, curve review, stored data and optional PC reporting.
Measurement intelligence
Automatic scan: recommends a suitable spindle and rotational-speed combination.
Range preview: displays the measurable viscosity range for the selected spindle and speed.
Curve display: shear rate-viscosity, temperature-viscosity and time-viscosity curves.
Kinematic viscosity: calculated after the sample density is entered.
Model comparison
ParameterVISCO500VISCO900EVISCO900S
Range, mPa.s1-100,0001-2,000,0001-2,000,000
Speed, rpm6 / 12 / 30 / 606 / 12 / 30 / 600.3 / 0.6 / 1.5 / 3 / 6 / 12 / 30 / 60
Error*±1%±0.5%±1%
Repeatability*±0.5%±0.25%±0.5%
Touch screen5 inch5 inch5 inch
Sample volume500 mL500 mL500 mL
*Performance values stated for Newtonian liquids in the source PDF.
Spindle selection is essentialThe customer must define the expected viscosity range and sample type before ordering. This information determines the correct four standard spindles. A complete seven-spindle set can also be ordered for broader application coverage.
VISCO900 range1-2,000,000 mPa.s
Standard sample500 mL
ProgramsUp to 30
Temperature-20 to 300 °C
Page 2 / 5
Technical Specifications and Functions
Measurement and control
ParameterSeries specification
Instrument typeDigital rotational viscometer
Control / display5-inch color LCD touch screen
VISCO900 range1 to 2,000,000 mPa.s
VISCO500 range1 to 100,000 mPa.s
Sample volume500 mL
VISCO900E speeds6 / 12 / 30 / 60 rpm
VISCO900S speeds0.3 / 0.6 / 1.5 / 3 / 6 / 12 / 30 / 60 rpm
Automatic scanAutomatic spindle and speed recommendation
Range indicationAutomatic display of measurable range for selected spindle and speed
Temperature probePt100 Class A supplied as standard
Temperature range-20 to 300 °C
Temperature resolution0.1 °C
Level adjustmentFront level for convenient instrument alignment
Data, methods and connectivity
ParameterSeries specification
Displayed dataDynamic viscosity, kinematic viscosity, temperature, shear rate, shear stress, torque/range percentage, spindle, speed, date and time
Viscosity curvesShear rate-viscosity, temperature-viscosity and time-viscosity
Kinematic viscosityCalculated after sample density input
Test programsUp to 30 user-defined methods including spindle, speed, temperature and time
Stored resultsUp to 30 data sets including viscosity, temperature, speed, shear data, time and density
Operating platformARM technology with embedded Linux system
Data interfaceRS232
PrinterOptional; data and curve printing through print interface
PC softwareOptional communication, acquisition, processing and storage software
Temperature controlOptional thermostatic bath, cooling bath, high-temperature tempering and special cup systems
Power supply220 V ±10%, 50 Hz
Dimensions300 x 300 x 450 mm
Method-development note: Viscosity range alone is not sufficient for final selection. Provide the expected minimum and maximum viscosity, sample temperature, sample type, available volume and required shear/speed conditions so the correct model, spindle set and temperature-control accessory can be confirmed.
Values are taken from the VISCO900 source PDF. The source table labels one model as “VISVO900E”; this document uses the corrected series designation “VISCO900E”.
Page 3 / 5
Spindle Selection and Standard Configuration
Required before quotation: define the working viscosity rangeThe four standard spindles are selected according to the customer’s application. Please provide the expected minimum and maximum viscosity, measuring temperature and sample description. Ordering the wrong spindle range may prevent the instrument from producing a valid measurement at the required speed and torque.
VISCO900 complete set of seven rotational viscometer spindles
Complete spindle range | all seven spindles can be ordered for maximum application coverage
VISCO900 standard set of four selected viscometer spindles
Standard configuration | four spindles selected according to the declared viscosity range
Information required
Viscosity range: expected minimum and maximum in mPa.s.
Sample: product type and whether behavior is Newtonian or non-Newtonian.
Temperature: measuring and conditioning temperature.
Standard four-spindle set
Application matched: selected to cover the declared working range.
Efficient configuration: avoids unnecessary spindles while covering routine samples.
Final selection: confirmed in the official quotation.
Complete seven-spindle set
Broad coverage: useful where sample viscosity varies substantially.
Method development: supports new products and wider R&D work.
Optional order: request the full set when future applications are uncertain.
Why spindle and speed must be considered together
The measurable range and generated torque depend on the combined selection of spindle geometry and rotational speed. VISCO900 automatically recommends an appropriate combination, but the ordered spindle set must physically cover the sample’s expected viscosity window.
For non-Newtonian materials, report the spindle, speed, temperature and measurement time together with the viscosity result to support method repeatability.
Page 4 / 5
VISCO900 | Standard and Optional Accessories
Temperature Control, Printing and Data Options
VISCO900 standard Pt100 temperature probe
Standard: Pt100 Class A temperature probe, -20 to 300 °C, 0.1 °C resolution
Optional VISCO900 high-temperature sample tempering accessories
Optional: high-temperature sample tempering accessory and special measuring cup system
Optional VISCO900 circulating thermostatic water bath
Optional: circulating thermostatic water bath or thermostatic cooling water bath
Optional printer for VISCO900 viscosity data and curves
Optional: external printer for measurement data and viscosity curves
Temperature control
Standard probe: monitors sample temperature directly.
Bath selection: choose heating or cooling according to the method range.
Stable results: controlled temperature improves viscosity repeatability.
Data and reporting
RS232: standard data-output interface.
PC software: optional acquisition, processing and storage.
Printer: optional direct printing of data and curves.
Quotation checklist
Model: VISCO900E or VISCO900S.
Spindles: selected four or complete seven.
Options: bath, high-temperature set, software and printer.
Selection and application support
COLO Lab Experts
Send the sample type, expected viscosity range, test temperature, available sample volume and required reporting method. We can confirm the model, spindle set and temperature-control configuration.
Quick contact
Web: colo.si
Address: Polje ob Sotli 4, SI-3255, Slovenia

Confirm the working range before selecting the spindle package

The standard package contains four application-selected spindles. Choose the complete seven-spindle set when the viscosity range is broad, future samples are unknown or the instrument will support method development.

Official configuration notice: This document supports product selection and does not replace the binding specification or delivered configuration confirmed in the official COLO.Science quotation and order confirmation. Spindles, temperature-control equipment, software, printer and other options must be confirmed for the specific application.
Page 5 / 5