📊 Technical Specifications
Performance
| Parameter | Specification |
| Max speed | 4000 rpm |
| Max RCF | 1880 × g * |
| Maximum capacity | 8 × 15 ml / 12 × 10 ml |
| Timer | 1 min - 99 min |
| Speed accuracy | ±10 rpm / min |
| Noise | ≤60 dB(A) |
| Typical use note | Suitable for routine and clinical bench protocols |
Drive and electrical data
| Parameter | Specification |
| Drive motor | DC brushless motor |
| Total power | 80 W |
| Power supply | AC 220 ±22 V, 50 Hz, 10 A |
| Universal power note | 220 V (±10%), 50-60 Hz mentioned in supplied marketing notes |
Dimensions and logistics
| Parameter | Specification |
| Size | 300 × 260 × 210 mm |
| Packing size | 380 × 340 × 285 mm |
| Weight | 7.5 kg |
| HS code | 8421199090 |
Construction and operation
| Parameter | Specification |
| Structure | Portable |
| Type | Table top / portable |
| Material | Plastic |
| Display | LCD display with backlight |
| Displayed parameters | Speed, RCF and time |
| Parameter change during run | Supported |
| Safety feature | Electromagnetic lid lock / closed-lid interlock sensor |
| Product page | Open MICE12 product page |
| Expected PDF | Open MICE12 PDF datasheet |
Important note on RCF value
Conflicting source value: supplied descriptive notes mention 4000 rpm / 2800 × g, while the tabulated specification lists Max. RCF 1880 × g.
Current document handling: the table uses 1880 × g as the formal value, but this should be verified before final publication or quotation issue.
Publishing note: keep this warning visible until the final manufacturer-confirmed RCF value is checked.
Rotor wording note
Standard rotor: 12 × 10 ml fixed-angle rotor.
Optional rotor: 8 × 15 ml fixed-angle rotor.
Check note: one input line mentions 12 × 15 ml; final rotor wording should be confirmed before catalog release.
Technical values are provided for product selection and orientation. Final delivered configuration, rotor type, accessory set and documentation should be confirmed through the official COLO.Science quotation or manufacturer-confirmed offer.
Page 3 / 5
COLO.Science · Final Support Page
COLO.Science · MICE12 compact centrifugation support
Need help selecting the correct MICE12 rotor configuration?
Send the preferred tube format, expected sample type, routine bench workload and whether MICE12 should be used as a primary compact centrifuge or as a backup unit.
COLO.Science can help confirm the suitable rotor, adapter requirement and quotation configuration.
Official configuration and manufacturer-confirmed specification notice:
This technical specification is provided for orientation, product selection and general information only. It does not represent the final binding technical specification, delivered configuration, accessory set, procurement requirement or acceptance criterion for a specific unit. The final official technical specification is only the specification confirmed by the manufacturer and issued for the exact configuration through an official COLO.Science quotation, proforma invoice, contract document, order confirmation or manufacturer-approved technical offer. Any values, options, accessories or configurations shown in this document must be verified for the specific delivery and should not be used as an exclusion or elimination criterion in procurement procedures without written manufacturer confirmation. For MICE12 specifically, please verify the final RCF value and exact optional rotor wording before final publication, quotation release or catalog printing.
Page 5 / 5