COLO.Science · Technical Specification
VIKING-PH310F
Portable pH / mV Meter · Temperature Measurement · 3-in-1 Electrode Kit
VIKING-PH310F Portable pH/mV Meter is a professional portable electrochemistry meter for accurate pH, mV and temperature measurement. The instrument combines a 3.5″ backlit LCD, 1–5 point pH calibration, automatic buffer recognition, electrode diagnostics, GLP data functions, USB output, rechargeable Li battery and IP65 protection in a compact portable format.
Portable pH meter pH / mV Temperature 3.5″ LCD ±0.01 pH 5-point calibration ATC / MTC USB GLP memory IP65
Document type: Technical Specification Sheet
Product family: Portable Electrochemistry / Water Quality Meter
Model: VIKING-PH310F · SKU: PRO3567
Product page: colo.si/product/viking-ph310f-portable-ph-temp-mv-with-3-in-1-electrode/
Format: A4 landscape · COLO.Science TechSpec v2.4 with navigation links
VIKING-PH310F portable pH meter main unit SKU PRO3567
VIKING-PH310F · portable pH / mV / temperature meter · main unit
Model / SKU VIKING-PH310F
PRO3567
Address / HQ Polje ob Sotli 4
SI-3255, Slovenia
Page 1 / 5
COLO.Science logo VIKING-PH310F · Portable pH / mV Meter
Technical data sheet · Informational document · Controlled electronic document
Product page: VIKING-PH310F on colo.si
VIKING-PH310F · technical specification Portable meter for pH, mV and temperature measurement with 3-in-1 pH electrode
pH range -2.00 to 20.00 mV ±2000.0 Temp. -5 to 110°C NIST / DIN / GB / USA Auto / timed / continuous read — Portable pH and mV measurement for field and laboratory use
📋 Product Overview
Application profile
Water quality: suitable for drinking water, wastewater, environmental samples and routine water monitoring.
Field and laboratory use: portable format with protective cover and carrying case for on-site and bench use.
Industrial sampling: supports pH, mV and temperature checks during process and quality control sampling.
Education and research: suitable for electrochemistry training, pH theory, millivolt measurement and calibration practice.
Design and handling advantage
Clear display: 3.5″ backlit LCD for measurement display, calibration status and routine operation.
Portable protection: silicone protective cover, wrist strap and carrying case support practical mobile operation.
Calibration control: 1–5 point pH calibration with automatic buffer recognition and selectable buffer groups.
Traceability: GLP functions and internal memory support measurement record management in routine QC workflows.
Key features
pH measurement: -2.00 to 20.00 pH range, 0.1 / 0.01 pH resolution and ±0.01 pH accuracy.
mV measurement: -2000.0 to 2000.0 mV range with 0.1 mV resolution.
Temperature measurement: -5 to 110°C range with ATC / MTC temperature compensation.
Measurement modes: Auto-Read, Timed-Read and Continuous-Read with Auto-Hold endpoint support.
Connectivity: USB output for simplified data transfer and reporting.
Protection: IP65 housing and rechargeable Li battery for portable operation.
Core technical summary
ParameterSpecification
ModelVIKING-PH310F
SKUPRO3567
Instrument typePortable pH / mV meter with temperature measurement
Display3.5″ LCD with backlight
pH range-2.00 to 20.00 pH
pH accuracy±0.01 pH
mV range-2000.0 to 2000.0 mV
Temperature range-5 to 110°C
Data logging500 results per parameter · GLP functions
ProtectionIP65
pH accuracy±0.01 pH
Calibration1–5 points
Data memory500 results / parameter
ProtectionIP65
Page 2 / 5
📊 Technical Specifications
Measurement ranges and performance
ParameterSpecification
pH range-2.00 to 20.00 pH
pH resolution0.1 / 0.01 pH
pH accuracy±0.01 pH
pH calibration1–5 points
Buffer recognitionAutomatic buffer recognition
Buffer groupsNIST, DIN, GB, USA; user-defined buffers supported
mV range-2000.0 to 2000.0 mV
mV resolution0.1 mV
mV accuracy±0.3 mV or ±0.1% FS
Temperature range-5 to 110°C / 23 to 230°F
Temperature units°C, °F
Temperature resolution0.1
Temperature accuracy±0.2°C
Temperature compensationATC / MTC
Measurement and reading modes
FunctionTechnical note
Auto-ReadFast / Medium / Slow reading stability options.
Timed ReadTimed reading mode for scheduled measurement intervals.
Continuous ReadContinuous measurement display for real-time monitoring.
Reading promptsReading / Stable / Locked prompts.
Endpoint captureAuto-Hold function for endpoint detection and locking.
System, data and connectivity
ParameterSpecification
Display3.5″ LCD with backlight.
Electrode diagnosticsAutomatic electrode diagnostics with pH slope and offset display.
Data capacity500 results per parameter.
GLP supportGLP functions with date and time record support.
pH electrode inputBNC / Q9 connector.
Temperature probe input4-pin aviation connector.
OutputUSB output for transfer and reporting.
Auto shutdown300 / 600 / 1200 / 1800 / 3600 seconds, or off.
Power supplyRechargeable Li battery; AC adapter 100–240 V AC input, 5 V DC output.
Protection ratingIP65 housing.
Dimensions80 × 255 × 35 mm.
WeightApprox. 400 g.
Product pageOpen VIKING-PH310F product page
Expected PDFOpen VIKING-PH310F PDF
Specification note
Electrode selection: final configuration should match the sample matrix, required pH range and temperature conditions.
Calibration: buffer group should match the laboratory procedure and reporting standard.
Field use: carrying case, wrist strap, protective cover and rechargeable battery support portable measurement workflows.
Technical values are provided for product selection and orientation. Final delivered configuration, electrode type, accessory set and documentation should be confirmed through the official COLO.Science quotation or manufacturer-confirmed offer.
Page 3 / 5
🧰 Standard Delivery, Accessories and Visual Support
VIKING-PH310F carrying case and accessories
VIKING-PH310F · carrying case and accessories
Typical standard delivery
PRO4153 3-in-1 composite pH electrode: supplied for routine pH, mV and temperature measurement workflows.
NIST pH buffer solutions: pH 4.01, 7.00 and 10.01; 50 mL per bottle.
Electrode holder: support accessory for stable electrode handling.
Protective cover: silicone protective cover and wrist strap for portable use.
Carrying case: protective storage and transport case for field and laboratory use.
Product image references
VIKING-PH310F portable pH meter main unit
Main unit · portable pH / mV / temperature meter
VIKING-PH310F portable pH meter kit with carrying case
Carrying case · accessories and standard kit

Navigation note — this specification is linked back to COLO.Science

This technical specification contains direct links to the product page, quotation request page, COLO.Science home page and water-quality knowledge area. If a user opens this document directly from Google or on a mobile device, the page remains connected to the main website and quotation path.

📌 Selection and Use Notes
For water quality
Routine pH: select appropriate buffers and electrode maintenance procedure.
mV measurement: confirm method and reporting requirement where millivolt readings are used.
For field work
Protection: use carrying case, wrist strap and protective cover during transport and field sampling.
Power: confirm battery charging before extended on-site measurement sessions.
For GLP workflows
Traceability: use date/time logging and review stored readings for measurement records.
Calibration: document buffer group, calibration points and electrode condition.
Page 4 / 5
COLO.Science · Final Support Page
Manufacturer and support
COLO Lab Experts
Polje ob Sotli 4, SI-3255, Slovenia
Selection guidance: Send the sample type, required pH range, temperature range, field/laboratory use case and preferred electrode configuration. COLO.Science can help confirm the correct VIKING-PH310F configuration and accessory set for your measurement workflow.
COLO.Science · VIKING-PH310F portable pH / mV meter support

Need help selecting the correct portable pH meter configuration?

Send the sample matrix, required measurement parameters, calibration standard, electrode type and expected field or laboratory use. COLO.Science can help confirm whether VIKING-PH310F is the correct configuration for your water quality, environmental or QA/QC workflow.

Official configuration and manufacturer-confirmed specification notice:
This technical specification is provided for orientation, product selection and general information only. It does not represent the final binding technical specification, delivered configuration, accessory set, procurement requirement or acceptance criterion for a specific unit. The final official technical specification is only the specification confirmed by the manufacturer and issued for the exact configuration through an official COLO.Science quotation, proforma invoice, contract document, order confirmation or manufacturer-approved technical offer. Any values, options, accessories or configurations shown in this document must be verified for the specific delivery and should not be used as an exclusion or elimination criterion in procurement procedures without written manufacturer confirmation.
Page 5 / 5