📊 Technical Specifications
Measurement ranges and performance
| Parameter | Specification |
| pH range | -2.00 to 18.00 pH |
| pH resolution | 0.01 pH |
| pH accuracy | ±0.01 pH |
| pH calibration | 1–3 points |
| Buffer recognition | NIST calibration recognition |
| mV range | -1999 to 1999 mV |
| mV resolution | 1 mV |
| mV accuracy | ±0.1% FS |
| Temperature range | -5 to 110°C |
| Temperature resolution | 0.1°C |
| Temperature accuracy | ±0.2°C |
| Temperature compensation | ATC / MTC |
Measurement and reading modes
| Function | Technical note |
| Auto Read | Automatic endpoint-supported reading mode for stable measurements. |
| Continuous Read | Continuous measurement display for routine monitoring. |
| Reading prompts | Reading / Stable / Locked status prompts. |
| Endpoint hold | Endpoint hold support for consistent measurement recording. |
| Routine use | Designed for laboratory and field pH/mV/temperature measurement workflows. |
System, memory and power
| Parameter | Specification |
| Display | 3.5″ LCD with backlight. |
| Data memory | 200 results per parameter. |
| pH electrode input | BNC / Q9 connector. |
| Temperature probe input | 4-pin aviation connector. |
| Backlight | Yes. |
| Auto power-off | 300 / 600 / 1200 / 1800 / 3600 seconds, or OFF. |
| Power supply | Rechargeable Li battery; AC adapter 100–240 V AC input, DC 5 V output. |
| Protection rating | IP65. |
| Dimensions | 80 × 225 × 35 mm. |
| Weight | 400 g / 0.88 lb. |
| Product page | Open VIKING-PH210 product page |
| Expected PDF | Open VIKING-PH210 PDF |
Specification note
Electrode selection: final configuration should match the sample matrix, required pH range and temperature conditions.
Calibration: NIST calibration procedure should match the laboratory’s internal method and documentation workflow.
Field use: IP65 housing supports portable operation; optional carrying case can be used for storage and transport.
Technical values are provided for product selection and orientation. Final delivered configuration, electrode type, accessory set and documentation should be confirmed through the official COLO.Science quotation or manufacturer-confirmed offer. Specifications may change without notice.
Page 3 / 5
COLO.Science · Final Support Page
COLO.Science · VIKING-PH210 portable pH / mV meter support
Need help selecting the correct portable pH meter configuration?
Send the sample matrix, required measurement parameters, calibration standard, electrode type and expected field or laboratory use.
COLO.Science can help confirm whether VIKING-PH210 is the correct configuration for your water quality, educational, environmental or QA/QC workflow.
Official configuration and manufacturer-confirmed specification notice:
This technical specification is provided for orientation, product selection and general information only. It does not represent the final binding technical specification, delivered configuration, accessory set, procurement requirement or acceptance criterion for a specific unit. The final official technical specification is only the specification confirmed by the manufacturer and issued for the exact configuration through an official COLO.Science quotation, proforma invoice, contract document, order confirmation or manufacturer-approved technical offer. Any values, options, accessories or configurations shown in this document must be verified for the specific delivery and should not be used as an exclusion or elimination criterion in procurement procedures without written manufacturer confirmation. Specifications may change without notice.
Page 5 / 5