COLO.Science · Technical Specification
VIKING-MPA300
Benchtop Multi Parameter Analyzer · pH / EC / ISE / mV / pX / Resistivity / TDS / Salinity / Temperature
VIKING-MPA300 Benchtop Multi Parameter Analyzer is a professional electrochemistry and water-quality instrument for laboratory measurement of pH, conductivity, ISE, mV, pX, resistivity, TDS, salinity and temperature. The analyzer combines a 7.0″ high-resolution LCD, GLP data handling, multi-reading modes, automatic/manual temperature compensation, USB and RS-232 communication and IP54 housing in a compact benchtop format.
Benchtop analyzer pH / EC / ISE mV / pX Resistivity / TDS / Salinity 7.0″ LCD ±0.01 pH ±0.5% ISE EC to 1000 mS/cm GLP memory USB / RS-232 IP54
Document type: Technical Specification Sheet
Product family: Benchtop Electrochemistry / Water Quality Analyzer
Model: VIKING-MPA300 · SKU: PRO6092
Product image: colo.si/wp-content/uploads/2024/02/MULTIWZ-.jpg
Format: A4 landscape · COLO.Science TechSpec v2.4 with navigation links
COLO.Science VIKING-MPA300 benchtop multi parameter analyzer pH EC ISE temperature SKU PRO6092
VIKING-MPA300 · benchtop multi parameter analyzer · main unit
Model / SKU VIKING-MPA300
PRO6092
Address / HQ Polje ob Sotli 4
SI-3255, Slovenia
Page 1 / 6
COLO.Science logo VIKING-MPA300 · Benchtop Multi Parameter Analyzer
Technical data sheet · Informational document · Controlled electronic document
COLO.Science: colo.si
VIKING-MPA300 · technical specification Benchtop analyzer for pH, EC, ISE, mV, pX, resistivity, TDS, salinity and temperature measurement
pH -2.00 to 20.00 mV ±2000.0 ISE 1.000e-9 to 9.999e+9 EC 0.000 μS/cm to 1000 mS/cm Temp. -5 to 110°C — Multi-parameter laboratory measurement with GLP records and PC output
📋 Product Overview
Application profile
Water quality laboratories: pH, conductivity, TDS, salinity, resistivity and temperature measurement for routine water and environmental samples.
Ion-selective measurement: ISE support with concentration units including μg/L, mg/L, g/L, mmol/L, ppm and ppb.
Quality control: suitable for general laboratory QA/QC where traceable calibration, data storage and repeatable reading modes are required.
Education and research: supports pH, mV, pX and ion-selective measurement methods in electrochemistry workflows.
Design and handling advantage
Large display: 7.0″ high-resolution LCD for clear bench operation and multi-parameter reading visibility.
Flexible reading: Auto-Read, Timed-Read and Continuous-Read modes with endpoint Auto-Hold.
Calibration control: up to 5-point pH and ISE calibration; up to 3-point conductivity calibration with standard recognition.
Connectivity: USB and RS-232 outputs support PC software, data transfer and printer communication.
Key features
pH measurement: -2.00 to 20.00 pH range, 0.1 / 0.01 pH resolution and ±0.01 pH accuracy.
ISE measurement: ion-selective concentration range from 1.000e-9 to 9.999e+9 with up to 4 significant digits.
Conductivity: 0.000 μS/cm to 1000 mS/cm range with selectable cell constant, temperature coefficient and TDS factor.
Temperature: -5 to 110°C measurement range with ATC and MTC compensation.
GLP memory: 500 data sets per parameter for pH, ISE, EC and temperature workflows.
Housing: IP54 water-resistant benchtop housing.
Core technical summary
ParameterSpecification
ModelVIKING-MPA300
SKUPRO6092
Instrument typeBenchtop multi parameter analyzer
Main parameterspH / EC / ISE / Temp. / mV / pX / Resistivity / TDS / Salinity
Display7.0″ high-resolution LCD
pH accuracy±0.01 pH
ISE accuracy±0.5%
EC accuracy±1.0% FS
Data logging500 results per parameter · GLP functions
ProtectionIP54
pH accuracy±0.01 pH
ISE calibrationUp to 5 points
EC range0.000 μS/cm - 1000 mS/cm
Data memory500 results / parameter
Page 2 / 6
📊 Technical Specifications · pH / mV / pX / ISE
Overview and pH performance
ParameterSpecification
ModelMPA300
ParameterspH / EC / ISE / Temp. (mV / pX / Resistivity / TDS / Salinity)
pH range-2.00 to 20.00 pH
pH resolution0.1 / 0.01 pH
pH accuracy±0.01 pH
pH calibration pointsUp to 5
pH standardsNIST, GB, USA, DIN
Additional buffer groupGOST listed in functional description
Slope limitYes
Electrode diagnosticsAutomatic electrode diagnostics with slope and offset display
mV and pX measurement
ParameterSpecification
mV range-2000.0 to 2000.0 mV
mV resolution0.1 mV
mV accuracy±0.3 mV or ±0.1%
pX range-2.00 to 20.00 pX
pX resolution0.1 / 0.01 pX
pX accuracy±0.01 pX
pX calibrationUp to 5 points
ISE - Ion-Selective measurement
ParameterSpecification
ISE range1.000e-9 to 9.999e+9
ISE unitsmol/L, mmol/L, g/L, mg/L, μg/L, ppm, ppb
Additional display unitsμg/L, mg/L, g/L, mmol/L, pX, ppm, ppb
ISE resolutionUp to 4 significant digits
ISE accuracy±0.5%
ISE calibrationUp to 5 points
Fitting modePolyline or linear fitting
Reading modeDirect Reading mode
Built-in methodsF-, Cl-, I-, NO3-, BF4-, NH4+, K+, Na+, Ca2+, Cu2+, Pb2+, Ag+, NH3-N + user methods
Reading control and GLP
FunctionTechnical note
Reading modesAuto-Read, Timed-Read and Continuous-Read
Auto modeFast / Medium / Slow reading stability options
Endpoint controlAuto-Hold detects and locks the measurement endpoint
PromptsReading, Stable, Locked
Temperature compensationAutomatic / Manual temperature compensation (ATC / MTC)
Data storage500 results per parameter
GLP featuresYes; date and time supported
DO note
Connector support: the provided specification lists a DO + temperature probe input with a 4-pin connector.
Range note: DO measurement range and DO accuracy are not defined in the supplied technical data and should be confirmed before quotation or tender submission.
Technical values are provided for product selection and orientation. Final delivered configuration, electrode type, probe set and documentation should be confirmed through the official COLO.Science quotation or manufacturer-confirmed offer.
Page 3 / 6
📊 Technical Specifications · Conductivity / Resistivity / TDS / Salinity / Temperature
Conductivity / Resistivity / TDS / Salinity
ParameterSpecification
Conductivity range0.000 μS/cm to 1000 mS/cm
EC resolutionMinimum 0.001 μS/cm; varies with range
EC accuracy±1.0% FS
Reference temperature20°C, 25°C
EC calibrationUp to 3 points
EC standards84 μS/cm, 1413 μS/cm, 12.88 mS/cm
Settable parametersCell constant, temperature coefficient, TDS factor
Compensation typesNone, linear, pure water
Resistivity5.00 Ω·cm to 20.00 MΩ·cm; minimum resolution 0.01 Ω·cm
TDS0.00 ppm to 300 ppt; minimum resolution 0.01 mg/L, varies with range
Salinity0.0-80.0 ppt; 0.00-8.00 %NaCl; resolution 0.1
Salinity accuracy±2 ppt
Conductivity workflow notes
Calibration control: use 84 μS/cm, 1413 μS/cm or 12.88 mS/cm standards according to the expected sample range.
Sample type: select temperature compensation mode according to routine conductivity, low-conductivity or pure-water workflow.
Reporting: conductivity, resistivity, TDS and salinity outputs should be confirmed against the laboratory method before use in QC records.
Temperature and measurement control
ParameterSpecification
Temperature range-5 to 110°C / 23 to 230°F
Temperature units°C, °F
Temperature resolution0.1
Temperature accuracy±0.2°C
Reading modesAuto (Fast / Medium / Slow), Timed, Continuous
PromptsReading, Stable, Locked
Temp. compensationATC, MTC
Endpoint controlAuto-Hold detects and locks the measurement endpoint
Factory resetFactory reset to default settings
DO input note
Connector support: the supplied specification lists a DO + temperature probe input with a 4-pin connector.
Confirmation required: DO range, resolution and accuracy are not defined in the supplied data and should be confirmed before quotation, tender submission or final product-page publication.
Document-use note
Technical orientation: values in this sheet are arranged for product selection, website publication and quotation preparation.
Configuration control: final delivered electrode/probe set should be verified through the official COLO.Science offer.
EC range0.000 μS/cm - 1000 mS/cm
EC accuracy±1.0% FS
Temperature-5 to 110°C
ModesAuto / timed / continuous
Page 4 / 6
🧰 System, Delivery Set, Selection Notes and Visual Support
Memory, inputs / outputs and general data
ParameterSpecification
Data storage500 results per parameter
GLP featuresYes
InputspH electrode (BNC/Q9); DO + Temp. probe (4-pin); Conductivity + Temp. probe (5-pin)
OutputsUSB (PC), RS-232 (printer)
PC softwareVia USB
BacklightYes
Auto shutdown1-60 min, or off
IP ratingIP54
Date and timeYes
PowerAC adapter, 100-240 V AC input, DC 20 V output
Dimensions242 × 195 × 68 mm
Net weight900 g / 1.98 lb
Carton370 × 305 × 330 mm; shipping weight 3.5 kg
Selection notes
pH workflow: confirm required buffer group, number of calibration points and electrode type for the sample matrix.
ISE workflow: confirm target ion, expected concentration range, reporting unit and whether a built-in or user-defined method is required.
Conductivity workflow: confirm cell constant, reference temperature, temperature compensation type and required EC / TDS / salinity output.
COLO.Science VIKING-MPA300 benchtop pH EC ISE multi parameter analyzer
VIKING-MPA300 · benchtop pH / EC / ISE / temperature analyzer
Standard included items
Included itemSpecification / SKU
pH electrode3-in-1 pH composite electrode — PRO4153
Conductivity electrodek=1, ATC, 2-20000 μS/cm, Φ12 × 120 mm — PRO6154
pH standardsNIST pH 4.01 / 7.00 / 10.01; 50 ml each
EC standard1413 μS/cm EC standard; 50 ml
Electrode standEHO-5 electrode stand

Navigation note — this specification is linked back to COLO.Science

This technical specification contains direct links to the product page, quotation request page, COLO.Science home page and water-quality knowledge area, so the document remains connected to the main website and quotation path.

Display7.0″ LCD
ProtectionIP54
InterfacesUSB + RS-232
Weight900 g
Page 5 / 6
COLO.Science · Final Support Page
Supplier and support
COLO Lab Experts
Polje ob Sotli 4, SI-3255, Slovenia
Selection guidance: send sample matrix, required parameters, target ions, conductivity range, temperature range, calibration standard and required electrode/probe configuration.
Quick contact
COLO.Science · VIKING-MPA300 support

Need help selecting the correct pH / EC / ISE analyzer configuration?

COLO.Science can help confirm whether VIKING-MPA300 is the correct benchtop analyzer configuration for your water quality, environmental, industrial or QA/QC workflow.

Model: VIKING-MPA300 · SKU: PRO6092 · Contact: sales@colo.si
Official configuration notice: this technical specification is provided for orientation and product selection only. The final binding specification, delivered configuration, accessory set and acceptance criteria are defined only by the official COLO.Science quotation, order confirmation or manufacturer-approved technical offer for the exact configuration.
Page 6 / 6