CO
COLO.Science · Technical Specification
Laboratory equipment · Water quality analysis
Document ID: COL-TEC-VIK256-EN
Format: A4 landscape · EN
Document type: technical specification
Laboratory turbidity meter · VIKING256

VIKING256

Laboratory Turbidity Meter · 0–1000 NTU · 0.01 NTU basic readout

VIKING256 is a benchtop laboratory turbidity meter for routine and wide-range turbidity measurement in drinking water, wastewater, environmental, industrial and research laboratory workflows.

The instrument is positioned as the wide-range model within the VIKING250 platform, using an 850 nm LED light source, 90° nephelometric detection, selectable NTU / FNU / EBC units, Formazin calibration, GLP-oriented data storage and USB / RS-232 communication.

0–1000 NTU0.01 NTU basic readout850 nm LED90° detectionNTU / FNU / EBCUSB / RS-232SKU PRO3321
Primary useWide-range routine turbidity measurement up to 1000 NTU
Optical principleNear-infrared 850 nm LED with 90° scattered-light detection
Data handlingUp to 2000 calibration curves / measurement data sets
COLO.Science supportModel selection, standards, cuvettes and quotation configuration
COLO.Science VIKING256 laboratory turbidity meter
COLO.Science · Technical overview

VIKING256 wide-range measurement platform

0–1000 NTU · 850 nm LED · GLP data
Measurement concept: VIKING256 uses a cold 850 nm LED light source and 90° nephelometric scattered-light detection. The configuration is suitable for routine samples where turbidity can vary from low values to higher process-water or wastewater ranges.
Common technical data
ModelVIKING256
Instrument typeBenchtop laboratory turbidity meter
Measurement parameterTurbidity
UnitsNTU, FNU and EBC selectable
Measurement principleNephelometric principle with 90° scattered-light detection
Light source850 nm LED, cold light source, narrowband interference optical design
Detector2 high-precision photodiodes: reference and 90° scattered-light measurement
Display4.3″ color LCD, backlit, user-friendly interface
Calibration1–6 points using Formazin standards or zero water; user-defined piecewise curves
Data storageUp to 2000 calibration curves / measurement data sets; GLP-oriented review
CommunicationUSB 2.0 and RS-232 interface for PC data transfer

Why VIKING256?

  • Dedicated wide-range VIKING250 platform model for 0–1000 NTU measurement.
  • Range-dependent resolution supports routine work across low, medium and high turbidity samples.
  • 850 nm LED and 90° nephelometric detection support ISO 7027-style near-infrared turbidity workflows.
  • GLP-oriented storage, user ID/date/time fields and PC communication support documentation.

Typical operator workflow

  • Select units: NTU, FNU or EBC.
  • Calibrate with appropriate Formazin standards or zero water.
  • Prepare and clean the cuvette carefully to reduce handling errors.
  • Measure sample and store / transfer data for reporting.
COLO.Science · Technical specifications

VIKING256 detailed specification

Focused VIKING256 data · with series context
VIKING256 measurement range and readout
Measuring range0 … 1000 NTU
Basic readout0.01 NTU
Resolution — low range0 … 20.00 NTU: 0.01 NTU
Resolution — mid range20.0 … 200.0 NTU: 0.1 NTU
Resolution — high range200 … 1000 NTU: 1 NTU
Listed accuracy in VIKING250 global spec±2% + 0.01 NTU
Repeatability±1% of reading or ±0.01 NTU, whichever is greater, under stable reference conditions
Allowed error±2% of reading
Operating and system data
Display4.3″ color LCD with backlight
Light source850 nm LED; cold light source; lifetime up to 100 000 h listed in platform spec
Optical detectorReference photodiode and 90° scattered-light photodiode
CalibrationFormazin standards / zero water; 1–6 point platform calibration
Data capacityUp to 2000 calibration curves / measurement records
InterfacesUSB 2.0 and RS-232
Ambient temperature5 °C … 40 °C
Power supply220 V ±10%, 50 Hz
WeightApprox. 3.5 kg net / 4.5 kg gross
Model context: VIKING256 is the wide-range VIKING250 model. It is selected when samples may exceed the low-turbidity range and coverage up to 1000 NTU is required.
ParameterVIKING255VIKING256 · Focus modelVIKING257
ApplicationLow-turbidity / drinking-water workWide-range routine laboratory turbidity measurementSmart multi-range measurement
Measuring range0 … 100 NTU0 … 1000 NTU0 … 1000 NTU
Basic readout0.001 NTU0.01 NTU0.001 / 0.01 NTU auto-ranging
Resolution details0–10 NTU: 0.001 NTU
0–100 NTU: 0.1 NTU
0–20.00 NTU: 0.01 NTU
20.0–200.0 NTU: 0.1 NTU
200–1000 NTU: 1 NTU
0–10 NTU: 0.001 NTU
0–100 NTU: 0.01 NTU
0–1000 NTU: 0.1 NTU
Technical verification note: the existing VIKING250 technical specification lists VIKING256 accuracy as ±2% + 0.01 NTU. The current product page contains an older/alternate line with Accuracy ±6% and RSD ≤0.5%. The final quotation should confirm which accuracy line is manufacturer-approved for the supplied configuration.
COLO.Science · Workflow and applications

Applications, delivery package and configuration notes

Laboratory turbidity workflows

Drinking water

Routine turbidity verification where stable calibration and traceable measurement documentation are required.

Wastewater and effluent

Wide-range turbidity checks in wastewater, effluent and treatment-process workflows up to 1000 NTU.

Environmental analysis

Surface water, rivers, lakes and environmental monitoring where NTU / FNU reporting is required.

Food and beverage

Process water and clarity-related checks where turbidity can indicate suspended matter or filtration performance.

Industrial utilities

Cooling water, process water and utility loops where increased turbidity may indicate particulate load or contamination.

Teaching and research

Benchtop turbidity measurement for laboratory teaching, method demonstration and research sample screening.

Typical delivery package

Instrument
VIKING256 main unit
Standards
0.02 NTU, 10 NTU and 1000 NTU calibration standard set
Cuvettes
5 high-precision glass cuvettes
Protection
Dust cover and light-tight measuring slot
Power
Power cord, 220 V / 50 Hz
Documentation
Instruction manual; USB cable, RS-232 optional on request

Optional accessories and checks

  • Additional Formazin calibration standards for application-specific ranges.
  • Replacement cuvettes and cuvette handling accessories.
  • Different standard sets depending on regulation and laboratory workflow.
  • Bluetooth or additional communication modules where available.
  • Final supplied kit should always be confirmed through the official quotation.
COLO.Science · Final page

Quotation, document links and technical notice

VIKING256 · contact and disclaimer

Configure VIKING256 for wide-range turbidity measurement

COLO.Science can support selection of the correct calibration standard set, cuvette package and data-transfer workflow for drinking water, wastewater, industrial and research laboratory applications where turbidity measurement up to 1000 NTU is required.

COLO.Science
Laboratory equipment, technical specification support and product configuration.
sales@colo.si
+386 64 222 724
colo.si

Recommended document links

  • Product page: /product/viking256-laboratory-turbidity-meter-001ntu/
  • Suggested HTML path: /wp-content/images/TechSpec/WaterQualityP/VIKING256.html
  • Suggested PDF path: /wp-content/images/TechSpec/WaterQualityP/VIKING256.pdf
  • Image asset: /wp-content/uploads/2022/01/VIKING255-E.jpg
  • SKU: PRO3321

Suggested short product line

VIKING256 is a benchtop laboratory turbidity meter for NTU / FNU / EBC measurement up to 1000 NTU, with 850 nm LED optics, 90° nephelometric detection, GLP data storage and USB / RS-232 communication.

Technical disclaimer: This COLO.Science technical specification is prepared for product orientation, quotation preparation and preliminary comparison only. Technical characteristics, supplied accessories and configuration options may vary depending on the confirmed offer, manufacturer documentation and selected model. Only the official quotation, order confirmation and manufacturer-approved specification should be treated as definitive for procurement, tender or contractual use.