VIKING256 is a benchtop laboratory turbidity meter for routine and wide-range turbidity measurement in drinking water, wastewater, environmental, industrial and research laboratory workflows.
The instrument is positioned as the wide-range model within the VIKING250 platform, using an 850 nm LED light source, 90° nephelometric detection, selectable NTU / FNU / EBC units, Formazin calibration, GLP-oriented data storage and USB / RS-232 communication.

| Model | VIKING256 |
|---|---|
| Instrument type | Benchtop laboratory turbidity meter |
| Measurement parameter | Turbidity |
| Units | NTU, FNU and EBC selectable |
| Measurement principle | Nephelometric principle with 90° scattered-light detection |
| Light source | 850 nm LED, cold light source, narrowband interference optical design |
| Detector | 2 high-precision photodiodes: reference and 90° scattered-light measurement |
| Display | 4.3″ color LCD, backlit, user-friendly interface |
| Calibration | 1–6 points using Formazin standards or zero water; user-defined piecewise curves |
| Data storage | Up to 2000 calibration curves / measurement data sets; GLP-oriented review |
| Communication | USB 2.0 and RS-232 interface for PC data transfer |
| Measuring range | 0 … 1000 NTU |
|---|---|
| Basic readout | 0.01 NTU |
| Resolution — low range | 0 … 20.00 NTU: 0.01 NTU |
| Resolution — mid range | 20.0 … 200.0 NTU: 0.1 NTU |
| Resolution — high range | 200 … 1000 NTU: 1 NTU |
| Listed accuracy in VIKING250 global spec | ±2% + 0.01 NTU |
| Repeatability | ±1% of reading or ±0.01 NTU, whichever is greater, under stable reference conditions |
| Allowed error | ±2% of reading |
| Display | 4.3″ color LCD with backlight |
|---|---|
| Light source | 850 nm LED; cold light source; lifetime up to 100 000 h listed in platform spec |
| Optical detector | Reference photodiode and 90° scattered-light photodiode |
| Calibration | Formazin standards / zero water; 1–6 point platform calibration |
| Data capacity | Up to 2000 calibration curves / measurement records |
| Interfaces | USB 2.0 and RS-232 |
| Ambient temperature | 5 °C … 40 °C |
| Power supply | 220 V ±10%, 50 Hz |
| Weight | Approx. 3.5 kg net / 4.5 kg gross |
| Parameter | VIKING255 | VIKING256 · Focus model | VIKING257 |
|---|---|---|---|
| Application | Low-turbidity / drinking-water work | Wide-range routine laboratory turbidity measurement | Smart multi-range measurement |
| Measuring range | 0 … 100 NTU | 0 … 1000 NTU | 0 … 1000 NTU |
| Basic readout | 0.001 NTU | 0.01 NTU | 0.001 / 0.01 NTU auto-ranging |
| Resolution details | 0–10 NTU: 0.001 NTU 0–100 NTU: 0.1 NTU | 0–20.00 NTU: 0.01 NTU 20.0–200.0 NTU: 0.1 NTU 200–1000 NTU: 1 NTU | 0–10 NTU: 0.001 NTU 0–100 NTU: 0.01 NTU 0–1000 NTU: 0.1 NTU |
Routine turbidity verification where stable calibration and traceable measurement documentation are required.
Wide-range turbidity checks in wastewater, effluent and treatment-process workflows up to 1000 NTU.
Surface water, rivers, lakes and environmental monitoring where NTU / FNU reporting is required.
Process water and clarity-related checks where turbidity can indicate suspended matter or filtration performance.
Cooling water, process water and utility loops where increased turbidity may indicate particulate load or contamination.
Benchtop turbidity measurement for laboratory teaching, method demonstration and research sample screening.
COLO.Science can support selection of the correct calibration standard set, cuvette package and data-transfer workflow for drinking water, wastewater, industrial and research laboratory applications where turbidity measurement up to 1000 NTU is required.
VIKING256 is a benchtop laboratory turbidity meter for NTU / FNU / EBC measurement up to 1000 NTU, with 850 nm LED optics, 90° nephelometric detection, GLP data storage and USB / RS-232 communication.