COLO.Science · Technical Specification

VIKING-M600

Benchtop Multi-Parameter Analyzer · pH / EC / ISE / DO / Temperature
Product family: Electrochemistry
Format: A4 landscape · EN
Document type: technical specification

VIKING-M600 is a touchscreen benchtop multi-parameter analyzer for precise laboratory measurement of pH, conductivity (EC), ion concentration (ISE), dissolved oxygen (DO) and temperature-related electrochemical parameters.

The platform combines a 7.0″ color touchscreen, modular measurement channels, GLP-compliant data management and guided measurement workflows for water laboratories, environmental monitoring, industrial quality control and research applications.

7.0″ touch LCD pH ±0.002 EC to 3000 mS/cm DO 0.00–99.99 mg/L 1000 results / parameter IP54 housing
Measured parameterspH, mV, ORP, pX, ISE, EC, resistivity, TDS, salinity, DO, % saturation and temperature.
Channel conceptpH/ISE, conductivity and dissolved oxygen modules with four configurable channels.
Data integrityGLP features, log management, data review, comparison and recalculation functions.
Laboratory useDesigned for bench analysis where multiple electrochemical methods must be traceable and repeatable.
COLO.Science VIKING-M600 benchtop multi-parameter analyzer main unit
COLO.Science · Measurement Platform

Key features and measurement modules

VIKING-M600 · EN technical specification
Modular multi-parameter analysis: VIKING-M600 supports pH/ISE, conductivity and dissolved oxygen workflows with automatic/manual temperature compensation, multiple reading modes and laboratory data handling functions.

General system features

  • 7.0″ high-contrast color LCD touchscreen.
  • Smart OS for user, calibration, method and data management.
  • Auto-read, timed-read and continuous-read modes.
  • Automatic or manual temperature compensation.
  • GLP-compliant data storage: 1000 result sets per parameter.
  • USB and RS-232 communication; USB 2.0 flash drive and printer support.
  • Factory reset function and IP54 splash-resistant housing.

pH / ISE channel

  • pH measurement from −2.000 to 20.000 pH with up to 0.001 pH resolution.
  • Up to 6-point calibration with NIST, GB and DIN buffer recognition.
  • Ion-selective measurement with direct reading, standard addition, sample addition and GRAN methods.
  • Built-in methods for common ions including F−, Cl−, Br−, I−, NO₃−, NH₄⁺, K⁺, Na⁺, Ca²⁺ and others.

Conductivity / EC channel

  • Conductivity range from 0.000 μS/cm to 3000 mS/cm.
  • Up to 5-point conductivity calibration with standard recognition.
  • Settable cell constant, reference temperature, temperature coefficient and TDS factor.
  • Temperature compensation types: none, linear and pure water.

Dissolved oxygen channel

  • Polarographic DO measurement from 0.00 to 99.99 mg/L.
  • % saturation range from 0.0 to 600%.
  • Calibration with air-saturated water or zero oxygen point.
  • Automatic barometric pressure compensation and manual salinity factor correction.

Standard delivery set

pH composite electrode PRO6139
Conductivity electrode
Temperature probe PRO6170
DO electrode, polarographic PRO6165
NIST pH standards 4.01 / 7.00 / 10.01, 50 ml each
EC standard 1413 μS/cm, 50 ml
EHO-3 electrode stand
Touch pen and bench accessories
COLO.Science · pH / mV / ISE

Electrochemical measurement specifications

VIKING-M600 · high-resolution pH and ISE analysis
pH measurement
Range−2.000 to 20.000 pH
Resolution0.1, 0.01, 0.001 pH
Accuracy±0.002 pH
Calibration pointsUp to 6
Standard recognitionNIST, GB, DIN
Custom buffersSupported
Calibration reminderYes
Electrode diagnosticsSlope and offset display
mV / ORP
Range−2000.00 to 2000.00 mV
Resolution0.1, 0.01 mV
Accuracy±0.1 mV or ±0.03%
EH ORP modeYes
ORP calibration1–2 custom points, relative mV
pX measurement
Range−2.000 to 20.000 pX
Resolution0.1, 0.01, 0.001 pX
Accuracy±0.002 pX
Calibration pointsUp to 6
ISE · Ion-selective measurement
Range1.000e−9 to 9.999e+9
Unitsmol/L, mmol/L, g/L, mg/L, μg/L
ResolutionUp to 4 significant digits
Accuracy±0.3%
Calibration pointsUp to 6
ModesDirect Reading, Standard Addition, Sample Addition, GRAN
Methods10+ built-in ion methods plus user methods

Typical pH / ISE workflow

  • Select method and electrode configuration.
  • Run guided calibration using recognized or custom standards.
  • Measure sample with temperature compensation.
  • Store, review and export GLP-compliant result records.
COLO.Science · EC / DO

Conductivity, salinity and dissolved oxygen specifications

VIKING-M600 · water quality bench analysis
Conductivity / EC
Conductivity range0.000 μS/cm to 3000 mS/cm
ResolutionMinimum 0.001 μS/cm, range-dependent
Accuracy±0.5% FS
CalibrationUp to 5 points
Standard recognition146.5 μS/cm, 1408 μS/cm, 12.85 mS/cm, 111.3 mS/cm
Reference temperature5, 10, 15, 18, 20, 25 °C
CompensationNone, linear, pure water
User settingsCell constant, temperature coefficient, TDS factor
Resistivity / TDS / Salinity
Resistivity5.00 Ω·cm to 100.0 MΩ·cm
Resistivity resolutionMinimum 0.01 Ω·cm
TDS range0.000 mg/L to 1000 g/L
TDS resolutionMinimum 0.001 ppm, range-dependent
Salinity type%NaCl
Salinity range0.00–8.00%
Salinity resolution0.01%
Salinity accuracy±0.1%
Dissolved Oxygen · polarographic
Concentration range0.00 to 99.99 mg/L
Concentration resolution0.01 mg/L
Concentration accuracy±0.1 mg/L
% saturation range0.0 to 600%
% saturation resolution0.10%
% saturation accuracy±2.0%
CalibrationAir-saturated water or zero point
Pressure compensationAutomatic barometric compensation
Salinity correctionManual factor
Calibration reminderYes

Common application areas

  • Drinking water, process water and wastewater laboratories.
  • Environmental monitoring and field sample verification at the bench.
  • Food, beverage, chemical and industrial QC laboratories.
  • Research and teaching laboratories requiring multi-parameter electrochemistry.
COLO.Science · Data / I/O / General

Temperature, data handling and instrument configuration

VIKING-M600 · GLP and connectivity
Temperature and reading modes
Temperature range−5 to 130 °C
Unit°C
Resolution0.1 °C
Accuracy±0.1 °C
Reading modesAuto (Fast/Medium/Slow), Timed, Continuous
PromptsReading, Stable, Locked
Temp. compensationATC, MTC
Data and GLP
Data storage1000 groups per parameter
GLP featuresYes
Log managementYes
Data functionsReview, comparison and recalculation
Inputs and outputs
pH electrode inputBNC (Q9)
DO + temperature probe6-pin Mini-DIN
Conductivity + temperature probe8-pin Mini-DIN
OutputsUSB, RS-232; USB 2.0 flash device; printer; PC
Display, housing and power
Display7.0″ color LCD touchscreen with backlight
Auto shutdown1–60 min or off
IP ratingIP54
Date and timeYes
PowerAC adapter, 100–240 V AC input, 24 V DC output

Dimensions

280 × 280 × 130 mm

Main unit dimensions

Net weight

2500 g · 5.51 lb

Instrument body

Shipping data

370 × 305 × 330 mm · 4 kg

Carton and shipping weight

Configuration note

Electrode and probe selection should be matched to the sample matrix, measurement range, required traceability and connector configuration. For complete system configuration, verify the supplied electrodes, optional ISE electrodes, calibration standards and consumables before purchase.

COLO.Science · Final Page

Quotation, configuration and technical notice

VIKING-M600 · contact and disclaimer

Configure the VIKING-M600 system for your laboratory workflow

COLO.Science can support selection of the main unit, electrodes, probes, calibration standards, ISE methods and accessories for water quality, environmental, industrial QC and research laboratory applications.

COLO.Science
Laboratory equipment, technical specification support and product configuration.
office@colo.si
https://colo.si/contacts/

Recommended document links

  • HTML path: /wp-content/images/TechSpec/pHP/VIKING-M600.html
  • PDF path: /wp-content/images/TechSpec/pHP/VIKING-M600.pdf
  • Product image: /wp-content/uploads/2025/07/I600-E.jpg

Suggested short product line

VIKING-M600 is a benchtop multi-parameter analyzer for pH, EC, ISE, dissolved oxygen and temperature measurement with 7.0″ touchscreen, modular channels and GLP data management.

Technical disclaimer: This COLO.Science technical specification is prepared for product orientation, quotation preparation and preliminary comparison only. Technical characteristics, supplied accessories and configuration options may vary depending on the confirmed offer, manufacturer documentation and selected electrodes/probes. Only the official quotation, order confirmation and manufacturer-approved specification should be treated as definitive for procurement, tender or contractual use.