COLO.Science · Technical Specification
VIKING-M510T-A
Portable pH / Conductivity / ISE / Dissolved Oxygen Multi-parameter Meter
VIKING-M510T-A Portable Multi-parameter Meter is a rugged IP65 field and laboratory electrochemistry platform for pH, mV/ORP, pX, ISE, conductivity, resistivity, TDS, salinity, dissolved oxygen and temperature. It combines a 4.3″ color touchscreen, intelligent method management, GLP-oriented memory and multiple reading modes for portable water quality, environmental, plant and QA/QC workflows.
Portable analyzer pH / mV / ORP ISE / pX EC conductivity TDS / salinity Resistivity Dissolved oxygen Temperature 4.3″ touchscreen USB 2.0 GLP memory IP65
Document type: Technical Specification Sheet
Product family: Portable Electrochemistry / Water Quality Multi-parameter Analyzer
Model: VIKING-M510T-A · SKU: To be confirmed
Main image: VIKING-M510T portable main unit image from COLO.Science template
Format: A4 landscape · COLO.Science TechSpec v2.4 with navigation links
VIKING-M510T-A portable pH conductivity ISE dissolved oxygen multi-parameter meter
VIKING-M510T-A · portable pH / EC / ISE / DO multi-parameter meter · main unit
Model / SKU VIKING-M510T-A
TBC
Address / HQ Polje ob Sotli 4
SI-3255, Slovenia
Page 1 / 5
COLO.Science logo VIKING-M510T-A · Portable pH / EC / ISE / DO Analyzer
Technical data sheet · Informational document · Controlled electronic document
Category: Portable multi-parameter analyzers
VIKING-M510T-A · technical specification Portable multi-parameter analyzer for pH, ISE, conductivity, ORP, pX, TDS, salinity, resistivity, dissolved oxygen and temperature
pH -2.000 to 20.000 ISE 1.000e-9 to 9.999e+9 EC 0.000 μS/cm to 3000 mS/cm DO 0.00 to 99.99 ppm Temp. -10 to 135°C — Portable workflow for laboratory, plant and field measurement
📋 Product Overview
Application profile
Water quality: designed for pH, conductivity, salinity, TDS, ISE, ORP and dissolved oxygen checks in water and process samples.
Field and laboratory use: portable IP65 format with touchscreen operation, rechargeable battery and compact 90 × 255 × 40 mm housing.
Ion measurement: supports ISE and pX work with direct, standard addition, sample addition and GRAN methods.
DO workflow: polarographic dissolved oxygen measurement with air-saturated water or zero-point calibration.
Design and handling advantage
Touchscreen workflow: 4.3″ high-contrast color LCD touchscreen with backlight for parameter setup and result review.
Calibration control: pH up to 8 points, EC up to 5 points, ISE up to 8 points and pX up to 6 points.
Traceability: GLP features and data storage for up to 1000 groups support routine documentation.
Operator support: Auto Read, Timed Read, Continuous Read and Auto-Hold endpoint detection reduce routine handling error.
Key features
Multi-parameter platform: pH, mV/ORP, pX, ISE, conductivity, resistivity, TDS, salinity, dissolved oxygen and temperature.
pH performance: -2.000 to 20.000 pH range, selectable 0.1 / 0.01 / 0.001 pH resolution and ±0.002 pH accuracy.
Conductivity performance: 0.000 μS/cm to 3000 mS/cm range with ±0.5% FS accuracy.
DO performance: 0.00 to 99.99 ppm dissolved oxygen concentration and 0.0 to 600.0% saturation.
Connectivity: USB 2.0 support for flash memory device, PC and scanner connection.
Core technical summary
ParameterSpecification
ModelVIKING-M510T-A
Instrument typePortable pH / conductivity / ISE / DO multi-parameter meter
Measured parameterspH, mV/ORP, pX, ISE, EC, resistivity, TDS, salinity, DO concentration, DO saturation, temperature
Display4.3″ color high-contrast LCD touchscreen with backlight
Reading modesAuto Read Fast / Medium / Slow, Timed Read and Continuous Read
Temperature compensationAutomatic / manual temperature compensation (ATC / MTC)
Data storage1000 groups; GLP features supported
ProtectionIP65 enclosure
pH accuracy±0.002 pH
EC accuracy±0.5% FS
DO range0.00–99.99 ppm
ProtectionIP65
Page 2 / 5
📊 pH / mV / ORP / pX / ISE Specifications
pH, mV, ORP and pX measurement
ParameterRange / resolution / accuracyCalibration / notes
pH range-2.000 to 20.000 pHUp to 8-point calibration
pH resolution0.1 / 0.01 / 0.001 pHSelectable resolution according to workflow
pH accuracy±0.002 pHSlope limit and calibration reminder supported
Buffer groupsUSA, NIST, MERK, JIS, GB, DINStandard customization supported
mV / ORP range-2000.00 to 2000.00 mVEH ORP mode supported
mV resolution0.1 / 0.01 mVRelative mV: 1 custom calibration point
mV accuracy±0.1 mV or ±0.03%For ORP and millivolt measurements
pX range-2.000 to 20.000 pXUp to 6-point calibration
pX resolution0.1 / 0.01 / 0.001 pXFor ion-selective workflows
pX accuracy±0.002 pXMethod-dependent performance
Reading and calibration workflow
FunctionTechnical note
Reading modesAuto Read Fast / Medium / Slow, Timed Read and Continuous Read.
Reading promptsReading / Stable / Locked status prompts with Auto-Hold endpoint detection.
ManagementUser, calibration, electrode, method, data and log management.
Temperature compensationAutomatic and manual temperature compensation for supported parameters.
ISE concentration measurement
ParameterSpecificationNotes
ISE range1.000e-9 to 9.999e+9Concentration measurement by selected ion method
ISE resolutionUp to 4 significant digitsDisplayed according to concentration range
ISE accuracy±0.3%Method and electrode dependent
ISE calibrationUp to 8 pointsSupports routine and advanced calibration curves
Unitsmol/L, mmol/L, g/L, mg/L, μg/L, ppm, ppb, pXSelectable concentration units
MethodsDirect, Standard Addition, Sample Addition, GRANBuilt-in ion measurement methods
Built-in ionsF−, Cl−, Br−, I−, NO₃−, BF₄−, NH₄⁺, K⁺, Na⁺, Ca²⁺, Cu²⁺, Pb²⁺ and Ag⁺; user-defined methods supported.
Electrode and method note
pH electrode: BNC / Q9 pH input for the delivered electrode configuration.
ISE workflow: select the ion electrode, ionic strength adjustment and calibration points according to the target sample matrix.
ORP workflow: confirm whether direct mV, relative mV or EH ORP reporting is required before defining the method.
pH calibrationUp to 8 points
ISE calibrationUp to 8 points
pX calibrationUp to 6 points
Technical values are provided for product selection and orientation. Final electrode type, calibration method, ion method, dissolved oxygen probe and accessory configuration should be confirmed through the official COLO.Science quotation or manufacturer-confirmed offer.
Page 3 / 5
⚙️ Conductivity / DO / Temperature / System Specifications
Conductivity-related parameters
ParameterRange / resolution / accuracyCalibration / notes
Conductivity0.000 μS/cm to 3000 mS/cmUp to 5-point calibration
EC resolutionMinimum 0.001 μS/cm; varies by rangeAuto-ranging display
EC accuracy±0.5% FSFull-scale accuracy
Reference temperature5, 10, 15, 18, 20, 25°CSelectable reference temperature
EC standards10 μS/cm, 84 μS/cm, 500 μS/cm, 1413 μS/cm, 12.88 mS/cm; 146.5 μS/cm, 1408 μS/cm, 12.85 mS/cm, 111.3 mS/cm.
Resistivity5.00 Ω·cm to 100.0 MΩ·cm0.01 Ω·cm minimum resolution; ±0.5% FS
TDS0.000 ppm to 1000 ppt0.001 ppm minimum resolution; ±0.5% FS
Salinity0.0 to 80.0 ppt0.1 ppt resolution; ±1 ppt accuracy
Dissolved oxygen measurement
ParameterSpecification
Sensor typePolarographic dissolved oxygen sensor
DO concentration range0.00 to 99.99 ppm
DO concentration resolution0.01 ppm
DO concentration accuracy±0.10 ppm from 0.00–50.00 ppm; ±0.50 ppm from 50.0–99.99 ppm
Calibration pointsAir-saturated water or zero point
CompensationAutomatic barometric compensation; manual salinity factor correction
DO saturation range0.0 to 600.0%
DO saturation resolution / accuracy0.10% resolution; ±2.0% accuracy
Temperature, inputs and system
ParameterSpecification
Temperature range-10 to 135°C / 14 to 275°F
Temperature resolution0.1
Temperature relative accuracy±0.1
Temperature units°C / °F
pH electrode inputBNC (Q9)
DO with temperature probe4-pin aviation connector
Conductivity with temperature probe5-pin aviation connector
USB outputUSB 2.0 for flash memory device, PC and scanner connection
BacklightYes
Date and timeYes
Auto shutdown300 / 600 / 1200 / 1800 / 3600 s or Off
Power supplyRechargeable lithium battery; AC adapter 100–240 V AC input, DC 5 V output
Dimensions / weight90 × 255 × 40 mm; approx. 500 g
VIKING-M510T-A carrying case and portable measurement accessories
VIKING-M510T-A · carrying case and typical portable measurement accessories
Typical standard delivery / configuration note
pH input: BNC (Q9) pH electrode input for the supplied pH electrode configuration.
Conductivity input: 5-pin aviation connector for conductivity probe with temperature measurement.
DO input: 4-pin aviation connector for DO probe with temperature measurement.
Accessories: final electrode set, DO probe, buffers, EC standards, electrolyte and carrying case should be confirmed for exact delivery.
DO sensorPolarographic
DO saturation0.0–600.0%
Memory1000 groups
DO values are listed for dissolved oxygen measurement configuration. Probe type, membrane/electrolyte consumables, calibration standards and delivery kit must be confirmed in the official offer.
Page 4 / 5
COLO.Science · Final Support Page
📌 Selection and Use Notes
For water quality
Routine pH / EC: define sample range, calibration buffers, EC standards and reporting units before purchase.
Salinity / TDS: confirm conversion factor, reference temperature and temperature compensation approach.
For ISE work
Ion method: choose direct, standard addition, sample addition or GRAN according to sample matrix.
Electrode set: select the correct ion-selective electrode and ionic strength adjustment procedure.
For DO workflows
Probe configuration: confirm DO probe, membrane/electrolyte requirements and calibration workflow.
Field use: IP65 housing, rechargeable battery and portable connectors support outdoor measurement routines.
Manufacturer and support
COLO Lab Experts
Polje ob Sotli 4, SI-3255, Slovenia
Selection guidance: Send the required parameters, sample matrix, expected measuring range, calibration method, electrode/probe type and field/laboratory use case. COLO.Science can help confirm the correct VIKING-M510T-A configuration and accessory set for your measurement workflow.
COLO.Science · VIKING-M510T-A portable multi-parameter analyzer support

Need help selecting the correct pH, EC, ISE and dissolved oxygen configuration?

Send the sample matrix, required parameters, expected ranges, electrode/probe configuration and calibration standards. COLO.Science can help confirm whether VIKING-M510T-A is the correct portable analyzer for water quality, environmental, plant or QA/QC workflow.

Technical specification path: VIKING-M510T-A HTML datasheet
Official configuration and manufacturer-confirmed specification notice:
This technical specification is provided for orientation, product selection and general information only. It does not represent the final binding technical specification, delivered configuration, accessory set, procurement requirement or acceptance criterion for a specific unit. The final official technical specification is the manufacturer-confirmed specification issued for the exact configuration through an official COLO.Science quotation, proforma invoice, contract document, order confirmation or manufacturer-approved technical offer. Values, options, accessories and configurations shown here must be verified for the specific delivery and should not be used as an exclusion criterion without written manufacturer confirmation.