| Parameter | Range | Resolution | Accuracy |
|---|---|---|---|
| pH | −2.000 to 20.000 pH | 0.1 / 0.01 / 0.001 | ±0.002 pH |
| ORP / mV | −2000 to +2000 mV | 0.1 / 0.01 mV | ±0.03% FS |
| ISE (Ion) | 1.00E−9 to 9.99E9 | 4 significant digits | ±0.3% |
| Temperature | −5 to 130 °C | 0.1 °C | ±0.1 °C |
| pX | −2.000 to 20.000 pX | 0.1 / 0.01 / 0.001 | ±0.002 pX |
pH accuracy: ±0.002 pH supports high-resolution laboratory measurement. ORP / mV range of −2000 to +2000 mV covers common redox and mV electrode workflows.
| Function | Specification / description |
|---|---|
| ISE calibration | 1–6 point ISE calibration |
| Supported ISE methods | Direct reading, standard addition, sample addition and Gran plot |
| ISE units | µg/L, mg/L, g/L, mmol/L and pX |
| Ion range | 1.00E−9 to 9.99E9 with 4 significant digits |
| Ion accuracy | ±0.3% |
| pX range / accuracy | −2.000 to 20.000 pX · ±0.002 pX |
| Optional DO module | Barometric and manual salinity compensation if installed |
| Function | Specification / note |
|---|---|
| Data management | GLP-compliant data management |
| Data storage | Up to 1000 data sets per parameter in instrument memory |
| User management | User, electrode, method and data management tools |
| Audit trail | Audit trails for traceable laboratory workflow |
| Calibration reminders | Reminder function for routine calibration and electrode management |
| Interfaces | USB and RS-232 for PC, printer or LIMS connection |
| Display / operation | 7.0″ touchscreen interface |
| Item | Details |
|---|---|
| Main unit | Viking ISE600 main unit · SKU: PRO6086 |
| Measurement module | pH / ISE measurement module |
| Laboratory accessories | Electrode holder and power adapter |
| Starter solutions | Starter set of calibration solutions |
| Data cable | USB cable for PC / printer connection |
| Documentation | Multilingual user manual and quick-start guide |
| Application support | Access to COLO.Science articles and application notes for water-quality measurements |

Electrodes, ISE probes, calibration solutions, DO module, printer / LIMS integration and accessories may vary by quotation. The official offer defines the final scope of supply.
Electrode choice: select pH and ORP electrodes according to sample type, temperature, matrix and expected measurement range.
Ion selection: choose the correct ion-selective electrode, standards and ionic-strength adjustment approach.
Connectivity: USB and RS-232 support PC, printer or LIMS connection depending on workflow.
COLO Lab Experts
Polje ob Sotli 4, SI-3255, Slovenia
Send the target parameters, required pH / ISE / ORP workflows, sample matrix, electrodes, calibration standards, data-output requirements and optional module needs.
Website: colo.si
Email: sales@colo.si
Phone: +386 64 222 724
Product: Viking ISE600 product page
Send the target parameters, sample type, expected concentration range, electrode requirements, data reporting workflow and optional module needs. COLO.Science can support Viking ISE600 product selection, accessory confirmation and quotation preparation.
Request quoteProduct pageWater quality resources