VIKING-EC500 is a benchtop conductivity meter for laboratories that require accurate, repeatable and traceable measurement of conductivity, resistivity, TDS, salinity and temperature.

The instrument combines a 7-inch high-contrast color LCD touchscreen, up to 5-point calibration, automatic/manual temperature compensation, GLP-compliant logging, data management and USB / RS-232 communication.

EC / Res / TDS / Sal / Temp7″ Touchscreen±0.5% FS1–5 point calibrationATC / MTC1000 groupsUSB / RS-232IP54
Conductivity range0.000 µS/cm to 2000 mS/cm with minimum resolution down to 0.001 µS/cm.
CalibrationUp to 5 points with automatic standard recognition and calibration reminder.
TraceabilityGLP features, log management and 1000 stored data groups for laboratory workflows.
COLO.Science VIKING-EC500 benchtop conductivity meter with electrode stand
COLO.Science · Conductivity Measurement

Key features and laboratory workflow

VIKING-EC500 · EN technical specification
Advanced EC platform: VIKING-EC500 is intended for laboratories that need a touchscreen conductivity meter with broad measurement range, multi-point calibration, selectable reference temperature, traceable data handling and multiple reading modes.

Key instrument features

  • 7-inch high-contrast color LCD touchscreen.
  • Intelligent OS with user, calibration, method and data management.
  • GLP-compliant logging with 1000 stored data groups.
  • Calibration up to 1–5 points with automatic standard recognition.
  • Automatic or manual temperature compensation: ATC / MTC.
  • Multiple reading modes: Auto-Read, Timed-Read and Continuous-Read.
  • On-meter data analysis: review, compare and recalculate.
  • USB and RS-232 communication for external workflows.
  • IP54 splash protection and factory reset to defaults.

Measurement scope

  • Conductivity: 0.000 µS/cm to 2000 mS/cm.
  • Resistivity: 5.00 Ω·cm to 100.0 MΩ·cm.
  • TDS: 0.000 ppm to 1000 ppt.
  • Salinity: 0.0 to 80.0 ppt as NaCl.
  • Temperature: −10 to 135 °C / 14 to 275 °F.
  • Input: EC + temperature probe with 5-pin aviation connector.

Measurement and data handling highlights

Conductivity accuracy ±0.5% FS
Conductivity resolution down to 0.001 µS/cm
EC calibration up to 5 points
Reference temperature 5 / 10 / 15 / 18 / 20 / 25 °C
Reading modes Auto / Timed / Continuous
Communication USB 2.0 / RS-232

Water quality labs

Broad EC range and temperature compensation support routine and method-driven water analysis.

QC environments

GLP logging, data review and communication interfaces support traceable QC workflows.

Research workflows

Multi-point calibration and selectable compensation settings support more demanding conductivity methods.

COLO.Science · EC / Resistivity / TDS / Salinity

Technical specifications

VIKING-EC500 · measurement performance
Conductivity and calibration
ModelVIKING-EC500
Measured parametersEC / Resistivity / TDS / Salinity / Temperature
Conductivity range0.000 µS/cm to 2000 mS/cm
Conductivity resolution0.001 µS/cm minimum, varies with range
Conductivity accuracy±0.5% FS
Reference temperature5, 10, 15, 18, 20, 25 °C, settable
EC calibrationUp to 5 points; calibration reminder
Standard recognition10, 84, 500, 1413 µS/cm; 12.88 mS/cm; 146.5 µS/cm; 1.408 mS/cm; 12.85 mS/cm; 111.3 mS/cm
Resistivity, TDS, salinity and temperature
Resistivity range5.00 Ω·cm to 100.0 MΩ·cm
Resistivity resolution0.01 Ω·cm minimum
Resistivity accuracy±0.5% FS
TDS range0.000 ppm to 1000 ppt
TDS resolution0.001 ppm minimum
TDS accuracy±0.5% FS
Salinity type and rangeNaCl; 0.0 to 80.0 ppt
Salinity resolution / accuracy0.1 ppt · ±1 ppt
Temperature range−10 to 135 °C / 14 to 275 °F
Temperature resolution / accuracy0.1 °C · ±0.1 °C
Temperature units°C / °F
Measurement, compensation and I/O
Reading modesAuto Read: Fast / Medium / Slow; Timed; Continuous
On-screen promptsReading / Stable / Locked
Temperature compensationATC / MTC
Compensation typesNone / linear / pure water
Settable optionsCell constant, temperature coefficient, TDS factor
Data & GLP1000 groups; GLP features; log management
CommunicationUSB 2.0: flash, PC, scanner; RS-232: printer, auto-sampler
Input connector5-pin aviation connector, EC + temperature probe
Display, power and physical data
Display7-inch high-contrast color LCD touchscreen; backlight
Auto shutdown1–60 minutes or off
ProtectionIP54 splash-proof protection
Date & timeYes
Factory resetYes
PowerAC adapter, 100–240 V input, DC 24 V output
Dimensions220 × 195 × 68 mm
Net weight950 g / 2.09 lb
COLO.Science · Use Guidance

Laboratory use, selection notes and method fit

VIKING-EC500 · practical configuration notes

When VIKING-EC500 is a suitable choice

  • When conductivity, resistivity, TDS, salinity and temperature are required in one instrument.
  • When a 7-inch touchscreen and guided user / method management are preferred.
  • When 1–5 point calibration and automatic standard recognition are important.
  • When laboratories need GLP-compliant data storage and log management.
  • When data export, printer connection or auto-sampler integration may be required.

Configuration and method checks

  • Confirm the conductivity range and expected sample matrix before quotation.
  • Select the correct EC electrode and cell constant for the target application.
  • Define reference temperature and temperature coefficient according to the method.
  • Use suitable standards across the expected measurement range.
  • Review reporting, GLP, USB and RS-232 requirements before final configuration.

Important measurement considerations

Conductivity measurement depends on electrode cell constant, temperature compensation settings, calibration standard condition, sample matrix, sample temperature and probe cleanliness. The wide conductivity range of VIKING-EC500 makes the instrument suitable for both low and high conductivity laboratory samples, but method suitability should always be checked against the expected range and acceptance criteria.

For SOP-compliant workflows, GLP logging, method management, review / compare / recalculate functions and export options help laboratories maintain traceability, reduce rework and document repeatable results.

Water quality

Routine and method-based checks for water, process water and environmental samples.

Production QC

Conductivity and TDS monitoring in food, beverage, chemical and pharmaceutical workflows.

Research

Advanced data handling and selectable compensation settings for demanding laboratory work.

COLO.Science · Links / Quotation / Notice

Product links, video placeholder and technical notice

VIKING-EC500 · contact and disclaimer

Configure VIKING-EC500 for traceable conductivity workflows

COLO.Science can support selection of conductivity meters, EC electrodes, calibration standards and accessories for water quality, QC, research and routine laboratory measurement.

COLO.Science
Laboratory equipment, technical specifications and product configuration.
sales@colo.si
+386 64 222 724
https://colo.si/contacts/

Recommended document links

Video presentation · in preparation

A VIKING-EC500 product video can be added later. It should present the touchscreen interface, EC calibration workflow, conductivity / resistivity / TDS / salinity measurement routines, electrode connection and data export options.

Temporary video placeholder: #viking-ec500-video
Replace this anchor with the final YouTube / product video URL when available.

Technical disclaimer: This COLO.Science technical specification is prepared for product orientation, quotation preparation and preliminary comparison only. Technical characteristics, supplied accessories and configuration options may vary depending on the confirmed offer, manufacturer documentation and selected electrode configuration. Only the official quotation, order confirmation and manufacturer-approved specification should be treated as definitive for procurement, tender or contractual use.

Company: COLO Lab Experts, Polje ob Sotli 4, SI-3255 Slovenia · www.colo.si · sales@colo.si · +386 64 222 724