COLO.Science · Technical Specification
VIKING-EC310
Portable Conductivity Meter · EC / TDS / Salinity / Resistivity / Temperature
VIKING-EC310 Portable Conductivity Meter is a compact IP65 field-ready conductivity meter for EC, TDS, salinity, resistivity and temperature measurement. The instrument combines a 3.5″ backlit LCD, ATC/MTC temperature compensation, 1–3 point calibration, GLP memory, USB communication and automatic endpoint hold in a portable format for laboratory and field water-quality workflows.
Portable conductivity meter EC TDS Salinity Resistivity Temperature 3.5″ LCD ATC / MTC USB GLP memory IP65
Document type: Technical Specification Sheet
Product family: Portable Electrochemistry / Water Quality Meter
Product: VIKING-EC310 · Model: EC310F
Product code / SKU reference: VIKING-EC310
Supplied EC electrode: PRO6154
Format: A4 landscape · COLO.Science TechSpec with navigation links
COLO.Science VIKING-EC310 portable conductivity meter main unit
VIKING-EC310 · portable conductivity / TDS / salinity / resistivity / temperature meter · main unit
Model VIKING-EC310
EC310F
Address / HQ Polje ob Sotli 4
SI-3255, Slovenia
Page 1 / 5
COLO.Science logo VIKING-EC310 · Portable Conductivity Meter
Technical data sheet · Informational document · Controlled electronic document
Support: request quotation and configuration check
VIKING-EC310 · technical specification Portable conductivity meter for EC, TDS, salinity, resistivity and temperature measurement
0.000 μS/cm to 500 mS/cm TDS 0.00 ppm to 300 ppt Salinity 0.0 to 80.0 ppt Resistivity up to 20.00 MΩ·cm Temp. −5 to 110°C — Portable conductivity platform for laboratory and field water-quality work
📋 Product Overview
Application profile
Water quality laboratories: suitable for conductivity, TDS, salinity and resistivity checks in routine laboratory workflows.
Environmental monitoring: portable IP65 format supports field sampling, outdoor measurements and mobile water testing.
Industrial process control: useful for process water, rinse water, raw water and general quality-control measurements.
Education and training: suitable for conductivity theory, cell constant adjustment and temperature compensation practice.
Design and handling advantage
Clear display: 3.5″ backlit LCD supports field and laboratory operation.
Portable protection: IP65 waterproof housing, silicone protective case, wrist straps and carrying case support mobile use.
Flexible readings: Auto-Read, Timed-Read and Continuous-Read modes support different measurement routines.
Traceability: GLP memory stores up to 500 results per parameter with date and time.
Key features
Conductivity: 0.000 μS/cm to 500 mS/cm range with ±1.0% FS accuracy.
Multi-parameter output: conductivity, resistivity, TDS, salinity and temperature in one portable meter.
Calibration: 1–3 point calibration with standard recognition for common EC standards.
Compensation: automatic and manual temperature compensation with none, linear and pure water options.
Connectivity: USB communication for PC or printer support.
Power: rechargeable lithium battery with AC adapter support and auto power-off.
Core technical summary
ParameterSpecification
ProductVIKING-EC310 Portable Conductivity Meter
ModelEC310F
Product code / SKU referenceVIKING-EC310
Instrument typePortable conductivity / TDS / salinity / resistivity meter with temperature measurement
Display3.5″ LCD with backlight
Conductivity range0.000 μS/cm to 500 mS/cm
Conductivity accuracy±1.0% FS
Temperature range−5 to 110°C / 23 to 230°F
Data logging500 results per parameter · GLP memory
ProtectionIP65 waterproof housing
Conductivity0.000 μS/cm to 500 mS/cm
Calibration1–3 points
Data memory500 sets / parameter
ProtectionIP65 waterproof
Page 2 / 5
📊 Technical Specifications
Measurement ranges and performance
ParameterSpecification
Conductivity range0.000 μS/cm to 500 mS/cm
Conductivity resolutionMinimum 0.001 μS/cm; resolution depends on measuring range
Conductivity accuracy±1.0% FS
Conductivity calibration1–3 point calibration with standard recognition
Recognized standards84 μS/cm, 1413 μS/cm, 12.88 mS/cm
Reference temperature20°C or 25°C
Resistivity range5.00 Ω·cm to 20.00 MΩ·cm
Resistivity resolutionMinimum 0.01 Ω·cm
Resistivity accuracy±1.0% FS
TDS range0.00 ppm to 300 ppt
TDS resolutionMinimum 0.01 ppm; range-dependent
TDS accuracy±1.0% FS
Salinity range0.0 to 80.0 ppt
Salinity resolution / accuracy0.1 ppt / ±2 ppt
Temperature range−5 to 110°C / 23 to 230°F
Temperature resolution / accuracy0.1 / ±0.2°C
System, compensation and connectivity
ParameterSpecification
Display3.5″ LCD display with backlight
Reading modesAuto-Read, Timed-Read and Continuous-Read
Auto-Read settingsFast / Medium / Slow stability options
Reading promptsReading / Stable / Locked status messages
Endpoint captureAuto-Hold function detects and locks endpoint value
Temperature compensationAutomatic and manual compensation: ATC / MTC
Compensation typesNone, linear and pure water
Adjustable parametersCell constant, temperature coefficient and TDS factor
Data capacity500 results per parameter with date and time; GLP memory
Probe inputEC + temperature via 5-pin aviation connector
OutputUSB communication for PC / printer support
Auto power-off300 / 600 / 1200 / 1800 / 3600 seconds, or off
Power supplyRechargeable lithium battery; AC adapter 100–240 V AC input, 5 V DC output
Dimensions80 × 225 × 35 mm
WeightApprox. 400 g / 0.88 lb
Shipping carton / gross weight410 × 330 × 165 mm; gross weight approx. 5 kg
Specification note
Electrode condition: measurement quality depends on probe condition, calibration quality and correct cell constant selection.
Temperature stability: compensation should be selected according to sample type and measurement procedure.
Field use: IP65 housing, protective case and rechargeable battery support portable conductivity workflows.
Technical values are provided for product selection and orientation. Final delivered configuration, electrode type, accessory set and documentation should be confirmed through the official COLO.Science quotation or manufacturer-confirmed offer.
Page 3 / 5
🧰 Standard Delivery, Accessories and Visual Support
COLO.Science VIKING-EC310 carrying case with conductivity standard solution and accessories
VIKING-EC310 · carrying case with standards and accessories
Typical standard delivery
PRO6154 EC electrode: supplied conductivity electrode for EC and related water-quality measurements.
1413 μS/cm EC standard solution: 50 mL, 1 vial, for routine conductivity calibration.
Electrode holder: support accessory for stable electrode handling during bench measurements.
Silicone protective case: protective cover for portable instrument use.
Wrist straps: practical handling support for field and mobile operation.
Carrying case: protective transport and storage case for mobile water-quality workflows.
Product image references
COLO.Science VIKING-EC310 portable conductivity meter main unit
Main unit · portable EC / TDS / salinity / resistivity meter
COLO.Science VIKING-EC310 connector detail with temperature connection
Connector area · EC and temperature connection detail

Navigation note — this specification is linked back to COLO.Science

This technical specification contains direct links to the quotation request page, COLO.Science home page, laboratory equipment area and water-quality knowledge section. If a user opens this document directly from Google or on a mobile device, the page remains connected to the main website and quotation path.

📌 Selection and Use Notes
For water quality
Conductivity: select the correct cell constant and calibration standard for the expected measuring range.
TDS: confirm the TDS factor according to the laboratory method or application requirement.
For field work
Protection: use the carrying case, wrist straps and silicone protective case during transport and field sampling.
Power: confirm battery charging before extended mobile measurement sessions.
For GLP workflows
Traceability: use date/time logging and review stored readings for measurement records.
Calibration: document standards, temperature compensation mode and electrode condition.
Page 4 / 5
COLO.Science · Final Support Page
Manufacturer and support
COLO Lab Experts
Polje ob Sotli 4, SI-3255, Slovenia
Selection guidance: Send the sample type, expected conductivity range, required measurement parameters, field/laboratory use case and preferred calibration standards. COLO.Science can help confirm the correct VIKING-EC310 configuration, electrode set and calibration solution package for your workflow.
COLO.Science · VIKING-EC310 portable conductivity meter support

Need help selecting the correct conductivity meter configuration?

Send the sample matrix, expected conductivity range, required EC/TDS/salinity/resistivity parameters, calibration standard and field or laboratory use case. COLO.Science can help confirm whether VIKING-EC310 is the correct configuration for your water quality, environmental or QA/QC workflow.

Official configuration and manufacturer-confirmed specification notice:
This technical specification is provided for orientation, product selection and general information only. It does not represent the final binding technical specification, delivered configuration, accessory set, procurement requirement or acceptance criterion for a specific unit. The final official technical specification is only the specification confirmed by the manufacturer and issued for the exact configuration through an official COLO.Science quotation, proforma invoice, contract document, order confirmation or manufacturer-approved technical offer. Any values, options, accessories or configurations shown in this document must be verified for the specific delivery and should not be used as an exclusion or elimination criterion in procurement procedures without written manufacturer confirmation.
Page 5 / 5