COLO.Science · Technical Specification

VIKING-EC300

Laboratory Conductivity Meter · EC / Resistivity / TDS / Salinity / Temperature
Model: VIKING-EC300
Product number / SKU: PRO-EC300
Product family: Conductivity meters
Format: A4 landscape · EN

VIKING-EC300 is a laboratory conductivity meter for accurate, repeatable and traceable measurement of conductivity, resistivity, TDS, salinity and temperature.

The instrument combines a 7.0-inch high-resolution LCD display, Auto-Read / Timed / Continuous modes, automatic or manual temperature compensation, Auto-Hold endpoint locking, GLP storage for 500 results per parameter and USB / RS-232 communication.

EC / Res / TDS / Sal / Temp 7.0″ LCD ±1.0% FS 1–3 point calibration ATC / MTC 500 results each USB / RS-232 IP54
Conductivity range0.000 µS/cm to 1000 mS/cm with minimum resolution down to 0.001 µS/cm.
CalibrationUp to 3 points with automatic recognition of 84 µS/cm, 1413 µS/cm and 12.88 mS/cm standards.
TraceabilityGLP features, date/time records and 500 stored results for each parameter.
COLO.Science VIKING-EC300 laboratory conductivity meter with electrode stand
COLO.Science · Conductivity Measurement

Key features and laboratory workflow

VIKING-EC300 · EN technical specification
Routine EC platform: VIKING-EC300 is intended for laboratories that need a stable LCD-based conductivity meter with 1–3 point calibration, ATC/MTC compensation, Auto-Hold endpoint locking, GLP storage and IP54 protection.

Key instrument features

  • 7.0-inch high-resolution LCD display with backlight.
  • Multiple reading modes: Auto Read, Timed and Continuous.
  • Auto Read supports Fast / Medium / Slow measurement behaviour.
  • Automatic and manual temperature compensation: ATC / MTC.
  • Auto-Hold detects and locks the measurement endpoint.
  • GLP-compliant storage: 500 results for each parameter.
  • USB and RS-232 outputs for PC and printer workflows.
  • Date and time stamping for laboratory traceability.
  • 1–3 point calibration with automatic standard recognition.
  • Settable cell constant, temperature coefficient and TDS factor.
  • Temperature compensation types: none, linear and pure water.
  • Auto shutdown: 1–60 minutes or off.
  • IP54 splash protection for routine laboratory environments.

Measurement scope

  • Conductivity: 0.000 µS/cm to 1000 mS/cm.
  • Resistivity: 5.00 Ω·cm to 20.00 MΩ·cm.
  • TDS: 0.00 ppm to 300 ppt.
  • Salinity: 0.0 to 80.0 ppt and 0.00 to 8.00 %NaCl.
  • Temperature: −5.0 to 110 °C / 23.0 to 230 °F.
  • Input: conductivity with temperature probe, 5-pin aviation connector.

Included delivery set

PRO6154
EC electrode
1413 µS/cm
EC standard solution, 50 mL, 1 vial
EHO5 / PRO6110
Electrode stand

Water quality

Routine EC, TDS, salinity and temperature measurement for water analysis workflows.

QC environments

GLP storage, endpoint locking and communication ports support traceable QC routines.

Research and education

Clear LCD operation and repeatable reading modes support teaching laboratories and routine research.

COLO.Science · EC / Resistivity / TDS / Salinity

Technical specifications

VIKING-EC300 · measurement performance
Conductivity and calibration
ModelVIKING-EC300
Measured parametersEC / Resistivity / TDS / Salinity / Temperature
Conductivity range0.000 µS/cm to 1000 mS/cm
Conductivity resolution0.001 µS/cm minimum, varies with range
Conductivity accuracy±1.0% FS
Reference temperature20, 25 °C
Calibration pointsUp to 3 points
Standard recognition84 µS/cm, 1413 µS/cm, 12.88 mS/cm
Resistivity, TDS, salinity and temperature
Resistivity range5.00 Ω·cm to 20.00 MΩ·cm
Resistivity resolution0.01 Ω·cm minimum
Resistivity accuracy±1.0% FS
TDS range0.00 ppm to 300 ppt
TDS resolution0.01 ppm minimum, varies with range
TDS accuracy±1.0% FS
Salinity range0.0–80.0 ppt; 0.00–8.00 %NaCl
Salinity resolution0.1 ppt; 0.1%
Salinity accuracy±2 ppt
Temperature range−5.0 to 110 °C / 23.0 to 230 °F
Temperature resolution / accuracy0.1 · ±0.2 °C
Temperature units°C / °F
Measurement, compensation and I/O
Reading modesAuto Read: Fast / Medium / Slow; Timed; Continuous
PromptsReading / Stable / Locked
Endpoint holdAuto-Hold with stable reading lock
Temperature compensationATC / MTC
Compensation typesNone / linear / pure water
Settable optionsCell constant, temperature coefficient, TDS factor
Data storage500 results each parameter, GLP features
Date and timeYes
InputsConductivity with temperature probe, 5-pin aviation connector
OutputsUSB, RS-232, PC / printer
Display, power and physical data
Display7.0-inch high-resolution LCD display; backlight: yes
Auto shutdown1–60 minutes, off
ProtectionIP54
PowerAC adapter, 100–240 V AC input, DC 20 V output
Instrument dimensions242 × 195 × 68 mm
Net weight900 g / 1.98 lb
Carton dimensions350 × 280 × 220 mm
Shipping weight2.5 kg
COLO.Science · Use Guidance

Laboratory use, selection notes and method fit

VIKING-EC300 · practical configuration notes

When VIKING-EC300 is a suitable choice

  • When EC, resistivity, TDS, salinity and temperature are required in one bench meter.
  • When the laboratory needs a reliable LCD-based meter for routine water quality workflows.
  • When 1–3 point calibration and automatic standard recognition are sufficient for the method.
  • When GLP storage, date/time records and stable endpoint detection are important.
  • When USB or RS-232 communication is needed for PC or printer workflows.

Configuration and method checks

  • Confirm the expected conductivity range and sample matrix before quotation.
  • Select the correct EC probe and cell constant for the application.
  • Use suitable standards at 84 µS/cm, 1413 µS/cm or 12.88 mS/cm according to the method range.
  • Define whether linear, pure water or no temperature compensation is required.
  • Review data export, printer and GLP storage requirements before final configuration.

Important measurement considerations

Conductivity measurement depends on electrode cell constant, temperature compensation settings, calibration standard condition, sample matrix, sample temperature and probe cleanliness. VIKING-EC300 covers routine laboratory conductivity ranges, but the selected electrode and method should always match the expected sample range and laboratory acceptance criteria.

For traceable workflows, Auto-Hold endpoint locking, GLP storage, date/time logging and USB / RS-232 communication help laboratories document repeatable results and reduce manual recording errors.

Water quality

Routine checks for water quality, process water, purified water, wastewater and environmental samples.

Production QC

Conductivity, TDS and salinity monitoring in food, beverage, chemical and pharmaceutical workflows.

Education and research

Repeatable LCD-based operation for teaching laboratories, research projects and method comparison.

COLO.Science · Links / Quotation / Notice

Product links, video placeholder and technical notice

VIKING-EC300 · contact and disclaimer

Configure VIKING-EC300 for routine conductivity workflows

COLO.Science can support selection of conductivity meters, EC electrodes, calibration standards and accessories for water quality, QC, research and routine laboratory measurement.

COLO.Science
Laboratory equipment, technical specifications and product configuration.
sales@colo.si
+386 64 222 724
https://colo.si/contacts/

Recommended document links

Video presentation · in preparation

A VIKING-EC300 product video can be added later. It should present the LCD interface, EC calibration workflow, conductivity / resistivity / TDS / salinity measurement routines, electrode connection and data export options.

Temporary video placeholder: #viking-ec300-video
Replace this anchor with the final YouTube / product video URL when available.

Technical disclaimer: This COLO.Science technical specification is prepared for product orientation, quotation preparation and preliminary comparison only. Technical characteristics, supplied accessories and configuration options may vary depending on the confirmed offer, manufacturer documentation and selected electrode configuration. Only the official quotation, order confirmation and manufacturer-approved specification should be treated as definitive for procurement, tender or contractual use.