VIKING-EC210 · Portable Conductivity / TDS Meter
VIKING-EC210 · technical specification
Portable conductivity / TDS meter for EC, TDS and temperature measurement
0.00 μS/cm to 200 mS/cm
TDS 0.00 ppm to 300 ppt
Temperature −5 to 110°C
ATC / MTC
Memory 200 sets / parameter
IP65
— Compact portable platform for routine conductivity and TDS water-quality work
📋 Product Overview
Application profile
Water quality laboratories: suitable for conductivity and TDS checks in routine laboratory workflows.
Field measurement: portable IP65 format supports mobile water testing, sampling support and quick site checks.
Industrial QC: useful for process water, rinse water, raw water and general conductivity control.
Education and training: suitable for conductivity theory, TDS factor, cell constant and temperature compensation demonstrations.
Design and handling advantage
Clear display: 3.5″ backlit LCD supports laboratory and field operation.
Portable protection: IP65 waterproof protection, silicone protective case and wrist straps support mobile use.
Reading stability: Auto Read and Continuous reading with Reading / Stable / Locked prompts and endpoint hold.
Traceability: stores up to 200 sets per parameter for practical measurement records.
Key features
Conductivity: 0.00 μS/cm to 200 mS/cm with ±1.0% FS accuracy.
TDS: 0.00 ppm to 300 ppt with range-dependent resolution.
Temperature: −5 to 110°C with 0.1°C resolution and ±0.2°C accuracy.
Calibration: EC calibration with standard recognition for 84 μS/cm, 1413 μS/cm and 12.88 mS/cm.
Compensation: ATC / MTC temperature compensation for routine conductivity measurement.
Power: rechargeable lithium battery with AC adapter support and selectable auto power-off.
Core technical summary
| Parameter | Specification |
| Product | VIKING-EC210 Portable Conductivity / TDS Meter |
| SKU | PRO6063 |
| Measured parameters | EC / TDS / Temperature |
| Display | 3.5″ backlit LCD |
| Conductivity range | 0.00 μS/cm to 200 mS/cm |
| Conductivity accuracy | ±1.0% FS |
| TDS range | 0.00 ppm to 300 ppt |
| Temperature range | −5 to 110°C |
| Memory | 200 sets per parameter |
| Protection | IP65 |
Conductivity0.00 μS/cm to 200 mS/cm
TDS0.00 ppm to 300 ppt
Memory200 sets / parameter
ProtectionIP65 waterproof
Page 2 / 5
📊 Technical Specifications
Measurement ranges and performance
| Parameter | Specification |
| Measured parameters | EC / TDS / Temperature |
| Conductivity range | 0.00 μS/cm to 200 mS/cm |
| Conductivity resolution | Minimum 0.01 μS/cm; resolution varies with range |
| Conductivity accuracy | ±1.0% FS |
| Reference temperature | 25°C |
| Conductivity calibration | 1–3 point calibration |
| Standard recognition | 84 μS/cm, 1413 μS/cm, 12.88 mS/cm |
| Cell constant | Settable |
| TDS range | 0.00 ppm to 300 ppt |
| TDS resolution | Minimum 0.01 ppm; resolution varies with range |
| TDS accuracy | ±1.0% FS |
| Temperature range | −5 to 110°C |
| Temperature unit | °C |
| Temperature resolution | 0.1°C |
| Temperature accuracy | ±0.2°C |
System, compensation and physical data
| Parameter | Specification |
| Product | VIKING-EC210 Portable Conductivity / TDS Meter |
| SKU | PRO6063 |
| Display | 3.5″ LCD with backlight |
| Reading modes | Auto Read, Continuous |
| Reading prompts | Reading / Stable / Locked |
| Endpoint capture | Endpoint hold / locked reading support |
| Temperature compensation | ATC / MTC |
| Data storage | 200 sets per parameter |
| Probe input | 5-pin aviation connector, EC + temperature |
| Backlight | Yes |
| Auto power-off | 300 / 600 / 1200 / 1800 / 3600 seconds, or off |
| Power supply | Rechargeable lithium battery; AC adapter 100–240 V input, DC 5 V output |
| Protection rating | IP65 — splash / spray protected, field-ready |
| Device dimensions | 80 × 255 × 35 mm |
| Device weight | 400 g / 0.88 lb |
Specification note
Electrode condition: measurement quality depends on probe condition, calibration quality and correct cell constant setting.
Temperature stability: ATC/MTC settings should match the sample and measurement procedure.
Field use: IP65 housing, protective case and rechargeable battery support portable conductivity workflows.
Technical values are provided for product selection and orientation. Final delivered configuration, electrode type, accessory set and documentation should be confirmed through the official COLO.Science quotation or manufacturer-confirmed offer.
Page 3 / 5
COLO.Science · Final Support Page
COLO.Science · VIKING-EC210 conductivity / TDS meter support
Need help selecting the correct conductivity meter configuration?
Send the sample matrix, expected conductivity range, required EC/TDS parameters, calibration standard and field or laboratory use case.
COLO.Science can help confirm whether VIKING-EC210 is the correct portable conductivity / TDS configuration for your workflow.
Official configuration and manufacturer-confirmed specification notice:
This technical specification is provided for orientation, product selection and general information only. It does not represent the final binding technical specification, delivered configuration, accessory set, procurement requirement or acceptance criterion for a specific unit. The final official technical specification is only the specification confirmed by the manufacturer and issued for the exact configuration through an official COLO.Science quotation, proforma invoice, contract document, order confirmation or manufacturer-approved technical offer. Any values, options, accessories or configurations shown in this document must be verified for the specific delivery and should not be used as an exclusion or elimination criterion in procurement procedures without written manufacturer confirmation.
Page 5 / 5