COLO.Science · Technical Specification
PRO6240
Fluoride Ion Selective Electrode · F- ISE · BNC(Q9) Connector
PRO6240 Fluoride Ion Selective Electrode is an ion-selective electrode for fluoride ion measurement in compatible ISE-capable meters. The electrode uses a crystalline-state membrane, plastic body and BNC(Q9) connector, and is intended for economical ion measurement workflows such as direct reading, standard addition, sample addition and GRAN methods when supported by the connected meter.
Fluoride ISE F- species 10-1 to 10-6 M Crystalline membrane Plastic body Ø12 × 120 mm 5–45°C BNC(Q9) Reference electrode required
Document type: Technical Specification Sheet
Product family: Electrochemistry / Ion Selective Electrodes
Model / SKU: PRO6240
Electrode type: Fluoride Ion Selective Electrode · F- ISE
Format: A4 landscape · COLO.Science TechSpec v2.4 with navigation links
Note: All product identification in this document refers to SKU PRO6240. Connector images are shown only as visual connection references.
COLO.Science PRO6240 fluoride ion selective electrode main unit
PRO6240 · fluoride ion selective electrode · main unit
Model / SKU PRO6240
Fluoride ISE
Address / HQ Polje ob Sotli 4
SI-3255, Slovenia
Page 1 / 5
COLO.Science logo PRO6240 · Fluoride Ion Selective Electrode
Technical data sheet · Informational document · Controlled electronic document
Contact: Request configuration confirmation
PRO6240 · technical specification Fluoride ion selective electrode for compatible ISE-capable meters
F- fluoride 10-1 M ~ 10-6 M Crystalline-state membrane BNC(Q9) Reference electrode required — Electrode configuration must match the meter and reference electrode system
📋 Product Overview
Application profile
Fluoride ion measurement: designed for fluoride ion activity / concentration measurement using a compatible ion meter or ISE-capable electrochemistry meter.
Routine ISE workflows: suitable for economical ion measurement where direct reading or addition-based methods are required.
Laboratory and QA/QC use: applicable in water, environmental, educational and routine analytical workflows where fluoride ion determination is required.
Method-dependent operation: available ISE modes such as Auto-reading, Standard Add, Sample Add and GRAN depend on the connected meter functions.
System concept
Ion-selective electrode: PRO6240 is the measuring electrode for fluoride ions.
Reference electrode: ISE measurement requires cooperation with a compatible reference electrode, for example 232-01-X reference electrode or equivalent confirmed configuration.
Connector compatibility: connector selection must match the meter input. PRO6240 is specified with BNC(Q9) connection; S7 versions require an S7-BNC(Q9) cable when applicable.
Single SKU principle: connector visual references in this document do not define a separate product SKU; the electrode SKU remains PRO6240.
Key features
Species: fluoride ion, F-.
Measuring range: 10-1 M to 10-6 M.
Membrane: crystalline-state membrane for fluoride ion-selective measurement.
Body: plastic electrode body for routine laboratory handling.
Dimensions: Ø12 × 120 mm electrode format.
Working temperature: 5–45°C operating range.
Connector: BNC(Q9), meter compatibility to be confirmed before delivery.
Core technical summary
ParameterSpecification
Model / SKUPRO6240
SpeciesFluoride (F-)
NameIon selective electrode
Measuring range10-1 M ~ 10-6 M
MembraneCrystalline-state membrane
BodyPlastic
DimensionØ12 × 120 mm
Working temperature5–45°C
ConnectorBNC(Q9)
Ion speciesFluoride F-
Range10-1–10-6 M
MembraneCrystalline-state
ConnectorBNC(Q9)
Page 2 / 5
📊 Technical Specifications
Electrode specification
ParameterSpecification
Model / SKUPRO6240
SpeciesFluoride (F-)
Product nameIon selective electrode
Electrode typeFluoride ion selective electrode
Measuring range10-1 M ~ 10-6 M
MembraneCrystalline-state membrane
Body materialPlastic
DimensionØ12 × 120 mm
Working temperature5–45°C
ConnectorBNC(Q9)
ISE measurement mode support
Measurement modeTechnical note
Auto-readingAvailable when supported by the connected ISE-capable meter.
Standard AddAddition-based ISE method; availability depends on meter software/function set.
Sample AddSample addition method; availability depends on meter software/function set.
GRAN methodsSupported only where the connected meter includes GRAN calculation functions.
Compatibility and configuration
ItemConfiguration note
Meter compatibilityUse only with a compatible ion meter or ISE-capable electrochemistry meter.
Reference electrodeISE probe requires a compatible reference electrode; example: 232-01-X reference electrode.
Connector requirementConnector must match the meter input. This configuration is specified as BNC(Q9).
S7 option noteWhere an S7 electrode configuration is used, an S7-BNC(Q9) cable is required to connect to a BNC(Q9) meter input.
Connector image noteConnector detail image is for visual reference only; it does not assign a second SKU to the electrode.
Single SKU ruleAll product identification in this technical sheet remains PRO6240.
Final configurationConfirm electrode, cable/reference electrode and meter compatibility in the official quotation.
Specification note
Sample matrix: confirm sample type, expected fluoride concentration range and any matrix preparation requirements before final configuration.
Reference system: final measurement reliability depends on correct pairing of ISE, reference electrode, meter and method settings.
Connector: BNC(Q9) compatibility should be checked against the selected meter input before delivery.
Documentation: final method, accessories and calibration/standard solutions should be confirmed for each quotation.
Technical values are provided for product selection and orientation. Final delivered configuration, reference electrode, connector/cable arrangement, accessory set and documentation should be confirmed through the official COLO.Science quotation or manufacturer-confirmed offer.
Page 3 / 5
🧰 Visual Support, Compatibility and Use Notes
PRO6240 fluoride ion selective electrode main unit
PRO6240 · fluoride ion selective electrode · main electrode body
Typical configuration logic
Main product: PRO6240 Fluoride Ion Selective Electrode.
Measurement species: fluoride ion F-.
Reference electrode: compatible reference electrode required for ISE measurement, such as 232-01-X or confirmed equivalent.
Meter connection: BNC(Q9) connector must match the meter input.
Cable note: if an S7 electrode/cable arrangement is used, confirm S7-BNC(Q9) cable compatibility with the meter.
Image references
PRO6240 fluoride ion selective electrode
Main unit · PRO6240 fluoride ISE electrode
BNC Q9 connector reference image for PRO6240 fluoride ion selective electrode
Connector detail · BNC(Q9) visual reference, not a separate SKU

SKU note — connector image is not a second product code

The electrode is identified in this document as PRO6240. The connector image is included only to help visually explain the BNC(Q9) connection type. Final connector/cable/reference-electrode compatibility should always be checked against the selected meter and confirmed before delivery.

📌 Selection and Use Notes
For fluoride ISE measurement
Range: check that expected sample concentration fits the 10-1 to 10-6 M measurement range.
Method: confirm whether direct reading, Standard Add, Sample Add or GRAN method is required.
For meter compatibility
Connector: confirm BNC(Q9) input or required adapter/cable before order confirmation.
Software: addition and GRAN methods require suitable meter functions.
For quotation
Include: meter model, desired measuring range, sample type and method requirement.
Confirm: electrode, reference electrode, cable and standards/accessories as one functional measurement set.
Page 4 / 5
COLO.Science · Final Support Page
Manufacturer and support
COLO Lab Experts
Polje ob Sotli 4, SI-3255, Slovenia
Selection guidance: Send the meter model, sample type, expected fluoride range, required ISE method and connector/reference-electrode requirements. COLO.Science can help confirm the correct PRO6240 electrode configuration and compatible accessory set for your measurement workflow.
COLO.Science · PRO6240 fluoride ion selective electrode support

Need help confirming the correct fluoride ISE configuration?

Send the meter model, sample matrix, expected fluoride concentration range, required method and connector/reference-electrode requirements. COLO.Science can help confirm whether PRO6240 is the correct fluoride ISE configuration for your laboratory workflow.

Product identification: PRO6240 Fluoride Ion Selective Electrode · Connector reference: BNC(Q9)
Official configuration and manufacturer-confirmed specification notice:
This technical specification is provided for orientation, product selection and general information only. It does not represent the final binding technical specification, delivered configuration, accessory set, procurement requirement or acceptance criterion for a specific unit. The final official technical specification is only the specification confirmed by the manufacturer and issued for the exact configuration through an official COLO.Science quotation, proforma invoice, contract document, order confirmation or manufacturer-approved technical offer. Any values, options, accessories, connector arrangements or configurations shown in this document must be verified for the specific delivery and should not be used as an exclusion or elimination criterion in procurement procedures without written manufacturer confirmation.