📊 Technical Specifications
Electrode specification
| Parameter | Specification |
| Model / SKU | PRO6240 |
| Species | Fluoride (F-) |
| Product name | Ion selective electrode |
| Electrode type | Fluoride ion selective electrode |
| Measuring range | 10-1 M ~ 10-6 M |
| Membrane | Crystalline-state membrane |
| Body material | Plastic |
| Dimension | Ø12 × 120 mm |
| Working temperature | 5–45°C |
| Connector | BNC(Q9) |
ISE measurement mode support
| Measurement mode | Technical note |
| Auto-reading | Available when supported by the connected ISE-capable meter. |
| Standard Add | Addition-based ISE method; availability depends on meter software/function set. |
| Sample Add | Sample addition method; availability depends on meter software/function set. |
| GRAN methods | Supported only where the connected meter includes GRAN calculation functions. |
Compatibility and configuration
| Item | Configuration note |
| Meter compatibility | Use only with a compatible ion meter or ISE-capable electrochemistry meter. |
| Reference electrode | ISE probe requires a compatible reference electrode; example: 232-01-X reference electrode. |
| Connector requirement | Connector must match the meter input. This configuration is specified as BNC(Q9). |
| S7 option note | Where an S7 electrode configuration is used, an S7-BNC(Q9) cable is required to connect to a BNC(Q9) meter input. |
| Connector image note | Connector detail image is for visual reference only; it does not assign a second SKU to the electrode. |
| Single SKU rule | All product identification in this technical sheet remains PRO6240. |
| Final configuration | Confirm electrode, cable/reference electrode and meter compatibility in the official quotation. |
Specification note
Sample matrix: confirm sample type, expected fluoride concentration range and any matrix preparation requirements before final configuration.
Reference system: final measurement reliability depends on correct pairing of ISE, reference electrode, meter and method settings.
Connector: BNC(Q9) compatibility should be checked against the selected meter input before delivery.
Documentation: final method, accessories and calibration/standard solutions should be confirmed for each quotation.
Technical values are provided for product selection and orientation. Final delivered configuration, reference electrode, connector/cable arrangement, accessory set and documentation should be confirmed through the official COLO.Science quotation or manufacturer-confirmed offer.
Page 3 / 5
COLO.Science · Final Support Page
COLO.Science · PRO6240 fluoride ion selective electrode support
Need help confirming the correct fluoride ISE configuration?
Send the meter model, sample matrix, expected fluoride concentration range, required method and connector/reference-electrode requirements.
COLO.Science can help confirm whether PRO6240 is the correct fluoride ISE configuration for your laboratory workflow.
Product identification: PRO6240 Fluoride Ion Selective Electrode · Connector reference: BNC(Q9)
Official configuration and manufacturer-confirmed specification notice:
This technical specification is provided for orientation, product selection and general information only. It does not represent the final binding technical specification, delivered configuration, accessory set, procurement requirement or acceptance criterion for a specific unit. The final official technical specification is only the specification confirmed by the manufacturer and issued for the exact configuration through an official COLO.Science quotation, proforma invoice, contract document, order confirmation or manufacturer-approved technical offer. Any values, options, accessories, connector arrangements or configurations shown in this document must be verified for the specific delivery and should not be used as an exclusion or elimination criterion in procurement procedures without written manufacturer confirmation.
Page 5 / 5