COLO.Science · Technical Specification
PRO6237
Combined Fluoride Ion Selective Electrode · F- ISE · BNC(Q9) Connector
PRO6237 Combined Fluoride Ion Selective Electrode is a combined ion-selective electrode for fluoride ion measurement in compatible ISE-capable meters. The combined electrode uses a crystalline-state membrane, plastic body and BNC(Q9) connector, and is intended for economical ion measurement workflows such as direct reading, standard addition, sample addition and GRAN methods when supported by the connected meter.
Combined Fluoride ISE F- species 10-1 to 10-6 M Crystalline membrane Plastic body Ø12 × 120 mm 5–45°C BNC(Q9) Combined ISE probe
Document type: Technical Specification Sheet
Product family: Electrochemistry / Combined Ion Selective Electrodes
Model / SKU: PRO6237
Electrode type: Combined Fluoride Ion Selective Electrode · F- ISE with integrated reference function
Format: A4 landscape · COLO.Science TechSpec v2.4 with navigation links
Note: All product identification in this document refers to SKU PRO6237. Connector images are shown only as visual connection references.
COLO.Science PRO6237 combined fluoride ion selective electrode main unit
PRO6237 · combined fluoride ion selective electrode · main unit
Model / SKU PRO6237
Combined Fluoride ISE
Address / HQ Polje ob Sotli 4
SI-3255, Slovenia
Page 1 / 5
COLO.Science logo PRO6237 · Combined Fluoride Ion Selective Electrode
Technical data sheet · Informational document · Controlled electronic document
Contact: Request configuration confirmation
PRO6237 · technical specification Combined fluoride ion selective electrode for compatible ISE-capable meters
F- fluoride 10-1 M ~ 10-6 M Crystalline-state membrane BNC(Q9) Combined ISE probe — Combined electrode configuration must match the selected meter input
📋 Product Overview
Application profile
Fluoride ion measurement: combined ISE probe designed for fluoride ion activity / concentration measurement using a compatible ion meter or ISE-capable electrochemistry meter.
Routine ISE workflows: suitable for economical ion measurement where direct reading or addition-based methods are required.
Laboratory and QA/QC use: applicable in water, environmental, educational and routine analytical workflows where fluoride ion determination is required.
Method-dependent operation: available ISE modes such as Auto-reading, Standard Add, Sample Add and GRAN depend on the connected meter functions.
System concept
Combined ISE electrode: PRO6237 combines the fluoride ion-selective measuring electrode with the reference electrode system in one probe body.
Integrated reference: the combined ISE probe includes the reference electrode function; a separate reference electrode is normally not required for this combined electrode format.
Connector compatibility: connector selection must match the meter input. PRO6237 is specified with BNC(Q9) connection; S7 versions require an S7-BNC(Q9) cable when applicable.
Single SKU principle: connector visual references in this document do not define a separate product SKU; the electrode SKU remains PRO6237.
Key features
Species: fluoride ion, F-.
Measuring range: 10-1 M to 10-6 M.
Membrane: crystalline-state membrane for fluoride ion-selective measurement.
Body: plastic electrode body for routine laboratory handling.
Dimensions: Ø12 × 120 mm electrode format.
Working temperature: 5–45°C operating range.
Connector: BNC(Q9), meter compatibility to be confirmed before delivery.
Core technical summary
ParameterSpecification
Model / SKUPRO6237
SpeciesFluoride (F-)
NameCombined Ion Selective Electrode
Measuring range10-1 M ~ 10-6 M
MembraneCrystalline-state membrane
BodyPlastic
DimensionØ12 × 120 mm
Working temperature5–45°C
ConnectorBNC(Q9)
Ion speciesFluoride F-
Range10-1–10-6 M
MembraneCrystalline-state
ConnectorBNC(Q9)
Page 2 / 5
📊 Technical Specifications
Electrode specification
ParameterSpecification
Model / SKUPRO6237
SpeciesFluoride (F-)
Product nameCombined Ion Selective Electrode
Electrode typeCombined fluoride ion selective electrode
Measuring range10-1 M ~ 10-6 M
MembraneCrystalline-state membrane
Body materialPlastic
DimensionØ12 × 120 mm
Working temperature5–45°C
ConnectorBNC(Q9)
ISE measurement mode support
Measurement modeTechnical note
Auto-readingAvailable when supported by the connected ISE-capable meter.
Standard AddAddition-based ISE method; availability depends on meter software/function set.
Sample AddSample addition method; availability depends on meter software/function set.
GRAN methodsSupported only where the connected meter includes GRAN calculation functions.
Compatibility and configuration
ItemConfiguration note
Meter compatibilityUse only with a compatible ion meter or ISE-capable electrochemistry meter.
Reference electrodeCombined ISE probe integrates the reference electrode function in the electrode assembly; separate reference electrode is normally not required for this combined format.
Connector requirementConnector must match the meter input. This configuration is specified as BNC(Q9).
S7 option noteWhere an S7 electrode configuration is used, an S7-BNC(Q9) cable is required to connect to a BNC(Q9) meter input.
Connector image noteConnector detail image is for visual reference only; it does not assign a second SKU to the electrode.
Single SKU ruleAll product identification in this technical sheet remains PRO6237.
Final configurationConfirm combined electrode, connector/cable arrangement and meter compatibility in the official quotation.
Specification note
Sample matrix: confirm sample type, expected fluoride concentration range and any matrix preparation requirements before final configuration.
Reference system: final measurement reliability depends on the combined ISE probe condition, compatible meter input and correct method settings.
Connector: BNC(Q9) compatibility should be checked against the selected meter input before delivery.
Documentation: final method, accessories and calibration/standard solutions should be confirmed for each quotation.
Technical values are provided for product selection and orientation. Final delivered configuration, combined electrode format, connector/cable arrangement, accessory set and documentation should be confirmed through the official COLO.Science quotation or manufacturer-confirmed offer.
Page 3 / 5
🧰 Visual Support and Compatibility Notes
PRO6237 combined fluoride ion selective electrode main unit
PRO6237 · combined fluoride ion selective electrode · main body
Configuration logic
Main product: PRO6237 combined fluoride ISE electrode.
Measured species: fluoride ion F-.
Combined design: measuring and reference functions are integrated in one electrode body.
Connector: BNC(Q9); meter compatibility must be confirmed before quotation.
Image references
PRO6237 combined fluoride ion selective electrode
Main electrode · SKU PRO6237
BNC Q9 connector reference image for PRO6237 combined fluoride ion selective electrode
BNC(Q9) connector reference · not a second SKU

SKU note — connector image is not a second product code

The electrode is identified as PRO6237. The connector image only explains the BNC(Q9) connection type. Final meter and cable compatibility should be confirmed before delivery.

Range: 10-1 to 10-6 M · Method: direct, addition or GRAN method according to meter function.
Quotation check: confirm meter model, sample type, concentration range, connector/cable and required standards as one functional ISE setup.
Page 4 / 5
COLO.Science · Final Support Page
Manufacturer and support
COLO Lab Experts
Polje ob Sotli 4, SI-3255, Slovenia
Selection guidance: Send the meter model, sample type, expected fluoride range, required ISE method and connector/cable requirements. COLO.Science can help confirm the correct PRO6237 electrode configuration and compatible accessory set for your measurement workflow.
COLO.Science · PRO6237 combined fluoride ion selective electrode support

Need help confirming the correct combined fluoride ISE configuration?

Send the meter model, sample matrix, expected fluoride concentration range, required method and connector/cable requirements. COLO.Science can help confirm whether PRO6237 is the correct combined fluoride ISE configuration for your laboratory workflow.

Product identification: PRO6237 Combined Fluoride Ion Selective Electrode · Connector reference: BNC(Q9)
Official configuration and manufacturer-confirmed specification notice:
This technical specification is provided for orientation, product selection and general information only. It does not represent the final binding technical specification, delivered configuration, accessory set, procurement requirement or acceptance criterion for a specific unit. The final official technical specification is only the specification confirmed by the manufacturer and issued for the exact configuration through an official COLO.Science quotation, proforma invoice, contract document, order confirmation or manufacturer-approved technical offer. Any values, options, accessories, connector arrangements or configurations shown in this document must be verified for the specific delivery and should not be used as an exclusion or elimination criterion in procurement procedures without written manufacturer confirmation.
Page 5 / 5