CO
COLO.Science · Technical Specification
Electrochemistry accessories / pH electrodes

Document type: Technical Specification Sheet

PRO6149 · pH Composite Electrode High Temperature Resistance

High-temperature pH composite electrode with glass body, ceramic junction, Longlife reference system, 3 M KCl fill solution and S7 connector.

SKU PRO6149 · pH 0-14 · -5 to 110 °C · Φ12 x 120 mm · S7 connector

Product overview

PRO6149 is a high-temperature resistant pH composite electrode for reliable pH measurement in demanding laboratory and process samples where the working temperature may exceed the practical range of standard routine electrodes.

The electrode combines pH indicator and reference functions in one glass-body probe. Its ceramic junction, 3 M KCl fill solution and Longlife reference system support stable measurement, reduced drift and extended service life in routine and thermally demanding applications.

Application profileHot water, chemical process samples, pharmaceutical QC and elevated-temperature laboratory workflows.
Connector profileS7 electrode connector. For meters with BNC pH input, use a compatible S7-BNC(Q9) cable.
Measurement rangeFull pH range 0-14 with working temperature from -5 to 110 °C.
Body formatGlass body, standard Φ12 x 120 mm format for holders and vessels.
PRO6149 pH Composite Electrode High Temperature Resistance glass electrode
PRO6149 · high-temperature resistant pH composite electrode · glass body · S7 connector
CO
PRO6149 · Technical data
High-temperature pH composite electrode

Core technical summary

ParameterSpecificationParameterSpecification
SKUPRO6149Product namepH Composite Electrode High Temperature Resistance
Electrode typeComposite pH electrodepH range0-14 pH
Sensor materialGlassBody materialGlass body
Reference typeLonglife referenceJunction materialCeramic junction
Fill solution3 M KClWorking temperature-5 to 110 °C
DimensionsΦ12 x 120 mmConnector typeS7

Electrode construction and materials

  • Composite pH format: pH indicator and reference electrode are integrated in one probe body.
  • Glass sensor and body: suitable for precise pH measurement and careful laboratory/process handling.
  • Ceramic junction: provides stable electrolyte contact with the sample.
  • 3 M KCl fill solution: supports stable reference potential and reproducible readings.
  • Longlife reference: intended for extended service stability and reduced drift compared with simple routine formats.

Measurement and operating profile

  • pH range: 0-14 pH.
  • Working temperature: -5 to 110 °C.
  • Typical use: hot process samples, hot water checks, chemical reactions, laboratory QC and environmental applications.
  • Temperature compensation note: this electrode does not include an integrated temperature probe. Use the meter temperature setting or a separate compatible temperature probe where automatic temperature compensation is required.

Compatibility notice - connector and meter matching are essential

This electrode has an S7 connector. For pH meters with BNC input, use a compatible S7-BNC(Q9) cable. Confirm the meter input, cable format and measurement method before ordering.

CO
Visual Reference, Connector and Compatibility
Electrode body · S7 connector · adapter cable requirement
PRO6149 high-temperature pH electrode body
Electrode body · glass pH composite electrode · Φ12 x 120 mm
PRO6149 S7 electrode connector reference image
Connector reference · S7 connector · use S7-BNC(Q9) cable for compatible BNC meters

Connector options and compatibility

Connector / optionTechnical note
S7Primary connector on this electrode. The electrode body ends in S7 format.
S7-BNC(Q9) cableRequired when using the electrode with pH meters that accept standard BNC pH electrode input.
Direct S7 inputFor meters or configurations that accept direct S7 connection, confirm cable requirement with the meter configuration.

Practical compatibility checklist

  • Meter input: confirm whether the pH meter uses BNC(Q9), S7 or another dedicated input.
  • Cable: include S7-BNC(Q9) cable when the meter has BNC pH input.
  • Temperature: high-temperature resistance does not automatically mean integrated temperature measurement.
  • Sample matrix: verify suitability for aggressive, viscous, non-aqueous or heavily contaminated samples before final selection.
CO
Selection and Use Notes
Calibration · high-temperature use · storage · handling

For high-temperature samples

  • Allow the electrode and sample to reach a stable measurement condition before recording final values.
  • Avoid unnecessary thermal shock where possible; rapid temperature changes can stress glass electrodes.
  • Use appropriate sample handling and vessel materials for hot liquids.
  • Confirm whether the application requires temperature compensation from the meter method.

For pH measurement

  • Calibrate with fresh pH buffers before routine measurement.
  • Use calibration buffers that match the expected measurement range.
  • Rinse the electrode between samples and avoid cross-contamination.
  • Follow the pH meter calibration and measurement procedure.

For electrode care

  • Keep the glass membrane hydrated according to the supplied electrode instructions.
  • Do not store the pH glass membrane dry unless the manufacturer instruction specifically permits it.
  • Clean according to sample contamination and laboratory procedure.
  • Inspect the junction and connector area before use.

General electrode notes

  • pH indicator electrode: requires a separate reference electrode.
  • Composite pH electrode: combines the pH indicator and reference electrode in one body.
  • 3-in-1 pH composite electrode: combines pH indicator, reference and temperature probe in one electrode assembly.
  • PRO6149 format: high-temperature resistant composite pH electrode with S7 connector.
  • Temperature measurement: requires a separate temperature probe or a 3-in-1 electrode model if automatic temperature measurement is needed.
  • Final selection: match sample matrix, pH range, working temperature and connector format.

Navigation note - this specification is linked back to COLO.Science

This technical specification contains direct links to the PRO6149 product page, quotation request path, COLO.Science home page and electrochemical instruments page. If a user opens this document directly from search results or from a shared PDF, the document remains connected to the main website and quotation workflow.

CO
COLO.Science · Final Support Page
Supplier support · official quotation · specification notice

Need help confirming the correct high-temperature pH electrode?

Send the pH meter model, connector type, sample matrix, operating temperature and whether automatic temperature compensation is required. COLO.Science can help confirm the correct electrode configuration or recommend a compatible alternative.

Supplier and support

COLO Lab Experts
Polje ob Sotli 4
SI-3255, Slovenia

Quick contact

sales@colo.si
+386 64 222 724
colo.si

Product reference

SKU PRO6149
pH 0-14 · -5 to 110 °C
S7 connector · Φ12 x 120 mm

PRO6149 · pH Composite Electrode High Temperature Resistance

A robust high-temperature pH electrode for demanding laboratory and process workflows, with glass body, ceramic junction, 3 M KCl fill solution, Longlife reference and S7 connector.

Official configuration and manufacturer-confirmed specification notice

This technical specification is provided for orientation, product selection and general information only. It does not represent the final binding technical specification, delivered configuration, accessory set, procurement requirement or acceptance criterion for a specific unit.

The final official technical specification is only the specification confirmed by the manufacturer and issued for the exact configuration through an official COLO.Science quotation, proforma invoice, contract document, order confirmation or manufacturer-approved technical offer.

Any values, options, accessories or configurations shown in this document must be verified for the specific delivery and should not be used as an exclusion or elimination criterion in procurement procedures without written manufacturer confirmation.