Technical Specifications
Electrode construction and measurement profile
| Parameter | Specification |
|---|
| Product name | pH premium glass electrode for ultra-pure water / Tris |
| Model / SKU | PRO5981 |
| Electrode type | pH composite electrode |
| Measurement parameter | pH |
| Recommended sample type | Ultra-pure water, low-conductivity water, deionized water, distilled water and Tris buffer solutions |
| pH range | 0-11 pH |
| Working temperature | 0-80 °C |
| Sensor material | Glass |
| Reference type | Longlife Reference |
| Junction material | Unmovable glass grinding mouth |
| Fill solution | 3 M KCl |
| Dimensions | Φ12×185 mm |
| Connector type | S7 |
Compatibility and use notes
| Topic | Technical note |
|---|
| Meter input | Requires compatible S7 connection or an S7-BNC(Q9) cable for pH meters with BNC input. |
| Temperature compensation | This is a pH electrode. Temperature compensation depends on the connected meter and separate temperature probe configuration. |
| Calibration | Calibrate with fresh pH buffers according to laboratory method, expected pH range and purified-water measurement practice. |
| Low-conductivity practice | Allow sufficient stabilization time and avoid sample contamination during measurement. |
| Storage | Store and clean according to the applicable laboratory method and electrode storage guidance. |
Product selection table
| Selection item | Specification / guidance |
|---|
| Recommended use | pH measurement in ultra-pure water and Tris buffer solutions where conventional electrodes may be unstable. |
| Best fit | Pharmaceutical water systems, biotechnology labs, purified-water QC, semiconductor support labs and research laboratories. |
| Handling advantage | Long glass electrode body supports deep vessels and stable laboratory positioning. |
| Reference design | Longlife Reference system for stable reference behavior in demanding applications. |
| Junction behavior | Unmovable glass grinding mouth junction supports stable contact between reference system and sample. |
| Instrument match | Confirm S7 connector compatibility or required S7-BNC(Q9) cable before ordering. |
| Product page | Open PRO5981 product page |
| Request quote | Contact COLO.Science for configuration confirmation |
Specification note
Connector matching: confirm whether the meter requires S7, BNC(Q9) or an S7-BNC(Q9) cable before ordering.
Low-conductivity practice: ultra-pure water has very low buffering capacity, so clean vessels and stable conditions are important.
Tris application: confirm method requirements and buffer type when selecting electrodes for biological buffer workflows.
Quotation control: final supplied configuration, cable, accessories and documentation should be confirmed in the official COLO.Science quotation.
Technical values are provided for product selection and orientation. Final delivered configuration, electrode type, accessory set, connector/cable arrangement and documentation should be confirmed through the official COLO.Science quotation or manufacturer-confirmed offer.
Page 3 / 5
COLO.Science · Final Support Page
Contact and Configuration Confirmation
Configuration before purchase
Need to match PRO5981 with a pH meter?
Send the meter model, required connector type and sample application. COLO.Science can confirm the correct S7 / S7-BNC(Q9) cable arrangement and quotation configuration.
COLO.Science · laboratory electrochemical instruments, pH electrodes and application support.
Disclaimer: This technical specification is an informational COLO.Science document prepared for product selection and communication. Product images, connector details, accessories, supplied cable configuration and technical values may be updated or adjusted by the manufacturer. Only the official quotation, order confirmation or manufacturer-confirmed technical documentation should be treated as the binding specification for procurement, tender or validation purposes.