COLO.Science · Technical Specification
PRO5981
Premium Glass pH Electrode for Ultra-Pure Water / Tris
Ultrapure water and Tris buffer pH electrode · Longlife Reference · unmovable glass grinding junction · S7 connector
PRO5981 pH Premium Glass Electrode is designed for accurate pH measurement in ultra-pure water, low-conductivity water and Tris buffer solutions, where standard pH electrodes may show slow response, unstable potential or measurement drift. The electrode uses a glass body, Longlife Reference system and unmovable glass grinding mouth junction to support stable liquid-junction behavior in demanding high-purity water workflows.
Ultra-pure waterTris compatiblepH 0-110-80 °CGlass bodyLonglife Ref.Glass grinding junction3 M KClS7 connectorΦ12×185 mm
Document type: Technical Specification Sheet
Product family: Electrochemical Instruments / pH Electrodes
Model / SKU: PRO5981
Product category: premium glass pH electrode for ultra-pure water and Tris buffer applications
Product page: ultra-pure-water-electrode
PRO5981 premium glass pH electrode for ultra-pure water and Tris
PRO5981 · premium glass pH electrode · ultra-pure water / Tris application
Model / SKUPRO5981
pH electrode
Address / HQPolje ob Sotli 4
SI-3255, Slovenia
Page 1 / 5
COLO.Science logoPRO5981 · Premium Glass pH Electrode
Technical data sheet · Informational document · Controlled electronic document
Product page: Ultra-pure water electrode on colo.si
PRO5981 · technical specificationpH premium glass electrode for ultra-pure water and Tris buffer measurement
pH range 0-11Working temp. 0-80 °CGlassLonglife Ref.3 M KClS7- Specialized electrode for high-purity water and Tris buffer laboratories
Product Overview
Application profile
Ultra-pure water: optimized for pH measurement in deionized, distilled and high-purity water samples.
Tris buffer solutions: suitable for biological and biochemical buffer work where Tris compatibility is required.
Low ionic strength: intended for samples where standard electrodes can drift, respond slowly or become unstable.
Extended reach: Φ12×185 mm body supports deeper vessels, flasks and laboratory setups requiring a longer electrode.
Design and measurement advantage
Composite pH electrode: pH measuring element and reference electrode are integrated in one practical probe.
Glass body: selected for chemical compatibility and stable laboratory measurement behavior.
Unmovable glass grinding junction: supports stable liquid junction potential in difficult high-purity water samples.
Longlife Reference: designed to provide durable reference behavior in demanding routine applications.
Key features
pH measurement: specified pH range from 0 to 11.
Body / sensor material: glass electrode body and sensor construction.
Reference system: Longlife Reference for stable operation.
Junction: unmovable glass grinding mouth junction.
Electrolyte: 3 M KCl fill solution.
Connection: S7 connector for compatible S7 cable or S7-BNC(Q9) cable setup.
Core technical summary
ParameterSpecification
Model / SKUPRO5981
Electrode typepH composite electrode for ultra-pure water / Tris
Fill solution3 M KCl
Sensor materialGlass
Reference typeLonglife Reference
Junction materialUnmovable glass grinding mouth
pH range0-11
Working temperature0-80 °C
DimensionsΦ12×185 mm
ConnectorS7
Sample typeUltra-pure water / Tris
pH range0-11
ReferenceLonglife Ref. · glass grinding junction
ConnectorS7
Page 2 / 5
Technical Specifications
Electrode construction and measurement profile
ParameterSpecification
Product namepH premium glass electrode for ultra-pure water / Tris
Model / SKUPRO5981
Electrode typepH composite electrode
Measurement parameterpH
Recommended sample typeUltra-pure water, low-conductivity water, deionized water, distilled water and Tris buffer solutions
pH range0-11 pH
Working temperature0-80 °C
Sensor materialGlass
Reference typeLonglife Reference
Junction materialUnmovable glass grinding mouth
Fill solution3 M KCl
DimensionsΦ12×185 mm
Connector typeS7
Compatibility and use notes
TopicTechnical note
Meter inputRequires compatible S7 connection or an S7-BNC(Q9) cable for pH meters with BNC input.
Temperature compensationThis is a pH electrode. Temperature compensation depends on the connected meter and separate temperature probe configuration.
CalibrationCalibrate with fresh pH buffers according to laboratory method, expected pH range and purified-water measurement practice.
Low-conductivity practiceAllow sufficient stabilization time and avoid sample contamination during measurement.
StorageStore and clean according to the applicable laboratory method and electrode storage guidance.
Product selection table
Selection itemSpecification / guidance
Recommended usepH measurement in ultra-pure water and Tris buffer solutions where conventional electrodes may be unstable.
Best fitPharmaceutical water systems, biotechnology labs, purified-water QC, semiconductor support labs and research laboratories.
Handling advantageLong glass electrode body supports deep vessels and stable laboratory positioning.
Reference designLonglife Reference system for stable reference behavior in demanding applications.
Junction behaviorUnmovable glass grinding mouth junction supports stable contact between reference system and sample.
Instrument matchConfirm S7 connector compatibility or required S7-BNC(Q9) cable before ordering.
Product pageOpen PRO5981 product page
Request quoteContact COLO.Science for configuration confirmation
Specification note
Connector matching: confirm whether the meter requires S7, BNC(Q9) or an S7-BNC(Q9) cable before ordering.
Low-conductivity practice: ultra-pure water has very low buffering capacity, so clean vessels and stable conditions are important.
Tris application: confirm method requirements and buffer type when selecting electrodes for biological buffer workflows.
Quotation control: final supplied configuration, cable, accessories and documentation should be confirmed in the official COLO.Science quotation.
Technical values are provided for product selection and orientation. Final delivered configuration, electrode type, accessory set, connector/cable arrangement and documentation should be confirmed through the official COLO.Science quotation or manufacturer-confirmed offer.
Page 3 / 5
Electrode Body and Connector Visual Support
PRO5981 premium glass pH electrode body
PRO5981 · complete electrode body · premium glass pH electrode for ultra-pure water / Tris
Visual reference and functional elements
Electrode body: glass shaft in Φ12×185 mm extended format for laboratory holders and deeper sample vessels.
Sensor area: pH-sensitive measuring end intended for low-conductivity and ultra-pure water pH measurement.
Reference system: Longlife Reference system to support stable performance in high-purity water and Tris buffers.
Junction: unmovable glass grinding mouth junction for stable liquid-junction behavior.
Connector: S7 connection; use compatible S7 connection or S7-BNC(Q9) cable when connecting to BNC meters.
Product image references
PRO5981 pH electrode body and sensor area
Electrode body · premium glass pH electrode
S7 BNC Q9 connector reference for pH electrode
Connector reference · S7 / S7-BNC(Q9) compatibility check required

Compatibility notice - connector and meter matching are essential

PRO5981 uses an S7 connector. When the pH meter has a BNC input, an S7-BNC(Q9) cable is required. Before ordering, verify the exact meter connector type, cable requirement and whether a separate temperature probe is needed for the intended measurement workflow.

Selection and Use Notes
For ultra-pure water
Sample handling: use clean vessels and avoid CO₂ absorption or contamination during measurement.
Stabilization: allow adequate reading stabilization time because low-conductivity samples respond differently from buffered samples.
For Tris buffers
Application fit: intended for pH work in Tris buffer solutions and high-purity water workflows.
Method check: verify buffer composition, temperature and calibration routine before measurement.
For ordering
Connector: confirm S7 connection or S7-BNC(Q9) cable requirement.
Documentation: request final quotation confirmation for supplied cable, packaging and accessories.
Page 4 / 5
COLO.Science · Final Support Page
Contact and Configuration Confirmation
COLO.Science support
PRO5981 · Premium Glass pH Electrode for Ultra-Pure Water / Tris
For quotation, connector confirmation, cable selection and delivery configuration, please contact COLO.Science. Confirm meter connector type, required cable, sample type and any temperature compensation requirement before ordering.
Quick contact
Configuration before purchase

Need to match PRO5981 with a pH meter?

Send the meter model, required connector type and sample application. COLO.Science can confirm the correct S7 / S7-BNC(Q9) cable arrangement and quotation configuration.

COLO.Science · laboratory electrochemical instruments, pH electrodes and application support.
Disclaimer: This technical specification is an informational COLO.Science document prepared for product selection and communication. Product images, connector details, accessories, supplied cable configuration and technical values may be updated or adjusted by the manufacturer. Only the official quotation, order confirmation or manufacturer-confirmed technical documentation should be treated as the binding specification for procurement, tender or validation purposes.
Page 5 / 5