COLO.Science · Technical Specification
TITRO5-E
Automatic Potentiometric Titrator · Titrimetric Analysis · Karl Fischer Moisture Application Support
TITRO5-E Automatic Potentiometric Titrator is a laboratory titration platform for precise titrimetric analysis, automatic potential titration and method-controlled endpoint workflows. It supports DET, MET, SET and manual titration modes, includes touchscreen operation, method and data storage, titration curve storage, GLP-oriented functions and output to printer or PC. Moisture content is one of the key parameters in many industrial and laboratory processes; when exceptional precision is required, especially for trace moisture applications, Karl Fischer titration is an essential analytical approach.
Automatic titrator Potential titration DET / MET / SET / MAT Touchscreen 100 methods 200 data sets 200 curves GLP pH / mV / Temp. PC / Print
Document type: Technical Specification Sheet
Product family: Automatic Titration / Water Quality and Analytical Laboratory Equipment
Model: TITRO5-E · SKU: PRO3380
Main application profile: titrimetric analysis, potentiometric titration and moisture-related analytical workflows
Format: A4 landscape · COLO.Science TechSpec v2.4 with navigation links
TITRO5-E automatic potentiometric titrator SKU PRO3380 main product
TITRO5-E · automatic potentiometric titrator · main product
Model / SKU TITRO5-E
PRO3380
Address / HQ Polje ob Sotli 4
SI-3255, Slovenia
Page 1 / 5
COLO.Science logo TITRO5-E · Automatic Potentiometric Titrator
Technical data sheet · Informational document · Controlled electronic document
Product inquiry: Request TITRO5-E quotation
TITRO5-E · technical specification Automatic potentiometric titrator for titrimetric analysis, endpoint titration and GLP-supported reporting workflows
Titrimetric analysis Automatic potential titration pH 0.000–20.000 mV ±2000.00 Temp. -5.0 to 105.0°C RSD ≤0.2% — Laboratory titration platform for quality control and analytical method workflows
📋 Product Overview
Application profile
Titrimetric analysis: designed for routine and method-controlled laboratory titration workflows.
Moisture-related workflows: supports analytical workflows where moisture content is a key process and quality parameter.
Quality control: suitable for industrial laboratories, research laboratories and QA/QC departments requiring repeatable titration data.
Method flexibility: supports acid-base, non-aqueous, precipitation, REDOX and complexometric titration applications.
Design and handling advantage
Touchscreen operation: intuitive user interface for method selection, measurement control and data handling.
Method storage: 100 titration method sets for standardized routine workflows.
Data management: 200 data sets and 200 titration curve sets support laboratory record review.
GLP orientation: GLP features help structure reporting and traceability in controlled laboratory environments.
Key features
Automatic potential titration: automatic endpoint-oriented titration based on potential measurement.
Multiple titration modes: DET, MET, SET and MAT modes for dynamic, monotone, preset endpoint and manual titration.
pH calibration and measurement: supports 1–3 point pH calibration and pH measurement.
Measurement inputs: pH, mV and temperature ranges support common potentiometric titration methods.
Output: printing and PC communication support reporting and result documentation.
Core technical summary
ParameterSpecification
ModelTITRO5-E
SKUPRO3380
Instrument typeAutomatic potentiometric titrator
Analysis typeTitrimetric analysis
ControlTouchscreen operation
Method storage100 titration method sets
Data storage200 data sets
Curve storage200 titration curve sets
RepeatabilityRSD ≤0.2%
OutputPrint and PC
Methods100 titration method sets
Data memory200 data sets
Curves200 titration curve sets
RepeatabilityRSD ≤0.2%
Page 2 / 5
📊 Technical Specifications
Measurement ranges and performance
ParameterSpecification
Analysis typeTitrimetric analysis
pH range0.000 to 20.000 pH
mV range-2000.00 to 2000.00 mV
Temperature range-5.0 to 105.0°C
RepeatabilityRSD ≤0.2%
10 mL burette accuracy±0.020 mL
20 mL burette accuracy±0.030 mL
pH calibration1–3 point pH calibration and measurement
Standard buffersNIST pH standard solutions: 4.01, 7.00 and 10.01
Titration modes
ModeDescription
DETDynamic equivalence point titration.
METMonotone equivalence point titration.
SETPreset endpoint titration.
MATManual titration.
System, methods and data handling
FunctionSpecification
Automatic titration typeAutomatic potential titration
User interfaceTouchscreen
Titration method sets100 sets
Data sets200 sets
Titration curve sets200 sets
GLP functionsSupported
OutputPrinter and PC
Titration methodsAcid-base including non-aqueous titration, precipitation, REDOX and complexometric titration.
Moisture application noteKarl Fischer titration is the preferred analytical approach for precise trace moisture determination when the method and configuration are confirmed.
Product inquiryContact COLO.Science for TITRO5-E configuration
Knowledge areaOpen Water Quality knowledge category
Specification note
Method confirmation: final titration method, electrode combination and burette configuration should be confirmed for the exact sample matrix.
Moisture determination: KF titration should be confirmed with the required method setup, reagent compatibility and delivered configuration before procurement.
Reporting: GLP features, curve storage, PC connection and print output support routine laboratory documentation.
Technical values are provided for product selection and orientation. Final delivered configuration, electrodes, burettes, reagent compatibility, accessory set and official documentation should be confirmed through the official COLO.Science quotation or manufacturer-confirmed offer.
Page 3 / 5
🧰 Standard Delivery, Electrodes and Visual Support
TITRO5-E automatic potentiometric titrator system image
TITRO5-E · automatic titrator system · SKU PRO3380
Packing includes
10 mL burette: standard burette included in the delivery set.
232-01 reference electrode: reference electrode for applicable potentiometric methods.
213-01 platinum electrode: platinum electrode for suitable REDOX and related titration workflows.
216-01 silver electrode: silver electrode for applicable precipitation and silver-electrode titration methods.
217-01 reference electrode: additional reference electrode included in the packing list.
231-01 pH indicator electrode: pH indicator electrode for pH measurement and acid-base titration applications.
T-818-B-6 temperature probe: temperature probe for temperature-supported measurement workflows.
NIST pH standard solutions: pH 4.01, 7.00 and 10.01; 50 mL per vial.
Method and configuration checklist
Before quotation
Sample matrix: confirm aqueous, non-aqueous, oil-based or other matrix type.
Target parameter: confirm moisture, acidity, alkalinity, chloride, REDOX or other titration target.
Endpoint logic: confirm equivalence point, preset endpoint or manual titration requirement.
Before delivery
Burette: confirm 10 mL or 20 mL burette requirement and dosing accuracy expectations.
Electrodes: confirm electrode compatibility with the titration method and reagent system.
Reporting: confirm PC, print and GLP documentation requirements.

Navigation note — this specification is linked back to COLO.Science

This technical specification contains direct links to the quotation request page, COLO.Science home page and water-quality knowledge area. If a user opens this document directly from Google or on a mobile device, the page remains connected to the main website and quotation path.

📌 Selection and Use Notes
For moisture workflows
KF requirement: confirm Karl Fischer method setup, reagent compatibility and measurement range.
Trace moisture: method validation is essential when working at very low moisture levels.
For general titration
Method type: confirm acid-base, precipitation, REDOX or complexometric method before configuration.
Electrode set: match the electrode to the chemistry and endpoint detection principle.
For GLP workflows
Documentation: use stored methods, data sets and titration curves for repeatability and review.
Output: confirm printer or PC workflow before final configuration.
Page 4 / 5
COLO.Science · Final Support Page
Manufacturer and support
COLO Lab Experts
Polje ob Sotli 4, SI-3255, Slovenia
Selection guidance: Send the sample matrix, titration target, required method type, moisture or non-moisture application, required burette volume, electrode configuration, reporting workflow and PC/print requirement. COLO.Science can help confirm the correct TITRO5-E configuration for the intended analytical method.
COLO.Science · TITRO5-E automatic potentiometric titrator support

Need help confirming the correct TITRO5-E titration configuration?

Send the sample matrix, analytical target, titration method, required burette size, electrode configuration and documentation requirements. COLO.Science can help confirm whether TITRO5-E is the correct configuration for your titrimetric analysis, moisture-related workflow or QA/QC method.

Official configuration and manufacturer-confirmed specification notice:
This technical specification is provided for orientation, product selection and general information only. It does not represent the final binding technical specification, delivered configuration, accessory set, procurement requirement or acceptance criterion for a specific unit. The final official technical specification is only the specification confirmed by the manufacturer and issued for the exact configuration through an official COLO.Science quotation, proforma invoice, contract document, order confirmation or manufacturer-approved technical offer. Any values, options, accessories, electrodes, burettes, reagent compatibility notes or configurations shown in this document must be verified for the specific delivery and should not be used as an exclusion or elimination criterion in procurement procedures without written manufacturer confirmation.
Page 5 / 5