COLO.Science · Technical Specification
COD100 · Technical Specification
| Instrument identity | |
|---|---|
| Model | COD100 |
| Instrument type | Laboratory COD analyzer |
| Measurement parameter | Chemical Oxygen Demand (COD) |
| Intended sample types | Water samples, wastewater, surface water, and industrial effluent |
| Compliance | Designed in line with ISO 15705:2002 and EPA 410.4 |
| Measurement ranges & optical detection | |
| Low-range COD | 0–150 mg/L |
| High-range COD | 150–1500 mg/L |
| Detection wavelength (low range) | 420 nm |
| Detection wavelength (high range) | 620 nm |
| Detection principle | Spectrophotometric measurement of generated Cr³⁺ after digestion |
| Performance parameters | |
| Accuracy | ±8% |
| Repeatability | ≤3% |
| Calibration concept | Two-point calibration using standard solutions |
| Memory capacity | Up to 200 sets of data |
| Data export | USB interface |
| Accessory model | COD100R Reactor |
| Sample capacity | Supports digestion of up to 21 samples simultaneously |
| Temperature range | Adjustable from 100–165 °C |
| Digestion time | Configurable from 0–120 minutes |
| System role | Dedicated digestion support for efficient batch preparation prior to COD measurement |
| Application field | Application description |
|---|---|
| Environmental laboratories | COD100 supports routine COD determination in laboratories focused on environmental water quality control, regulatory sample evaluation, and laboratory-based compliance workflows. |
| Water treatment facilities | Suitable for process monitoring and verification tasks in water and wastewater treatment environments where repeatable digestion-based COD analysis is required. |
| Industrial wastewater monitoring | Useful for laboratories and industrial facilities that need standardized COD testing of effluent streams and process-related water samples. |
| Surface water testing | Applicable to routine assessment of contamination load and oxygen demand indicators in surface water samples. |
| Operational highlights | |
|---|---|
| Method reliability | Digestion plus spectrophotometric detection provides a classical and standardized COD workflow. |
| Range flexibility | Dual wavelength approach supports both lower and higher COD concentration ranges. |
| Laboratory efficiency | The optional COD100R reactor improves batch handling and digestion efficiency. |
| Practical notes | |
|---|---|
| Configuration note | Final package may include analyzer only or analyzer plus COD100R digestion reactor, depending on workflow needs. |
| Application note | Method suitability should be confirmed against the laboratory’s internal SOP, standards, and target concentration range. |
| Document note | This sheet summarizes the visible technical and application information supplied for the COD100 system. |
Use this technical specification as a reference document, then continue to the COLO website, request a quotation for the COD100 configuration, or explore application guidance and laboratory knowledge resources.