COLO.Science · Technical Specification
COLO-DT1206AT
Automatic Sampling Dissolution System · 12 cups / 12 shafts
High-throughput dissolution testing platform for pharmaceutical research, formulation development, method validation and quality control. 12 × 1000 mL vessels, water bath heating and temperature control RT–45 °C with deviation < ±0.2 °C. Speed range 10–300 rpm, integrated dosing, 12-channel injection-pump sampling, online two-stage filtration, automatic replenishment and cleaning — built for reproducible USP/ChP workflows.
USP / ChP Mechanical validation 12 cups Auto dosing Auto sampling Data integrity 6+6 zones
Typical applications: tablets / capsules / granules · dissolution profiling · batch release testing · stability studies
Document type: Technical Specification Sheet · Format: Landscape (Word/Outlook-ready)
COLO-DT1206AT automatic sampling dissolution system (host + sampler)
Instrument
COLO-DT1206AT · automatic sampling dissolution · PRO6781
Address (HQ)
Polje ob Sotli 4
SI-3255, Slovenia
Contact
COLO Science logo COLO-DT1206AT · Technical Specification
Document ID: COL-TEC-COLO-DT1206AT-EN
SKU / Product No.: PRO6781
Version: Landscape
Informational technical sheet · Non-binding · Controlled electronic document

COLO-DT1206AT · automatic sampling dissolution system technical specification sheet

pharma QC R&D method validation paperless audit trail — 12 cups / 12 shafts, 10–300 rpm, RT–45 °C (±0.2 °C), 12-channel injection-pump sampling, 156-position rack

📋 general & performance specifications

instrument identity
nameAutomatic Sampling Dissolution
type / modelCOLO-DT1206AT (DS-1206AT)
sku / product numberPRO6781
dissolution cups quantity12 cups (1000 mL glass vessels)
🧭 mechanical alignment (validation relevant)
levelness≤ 0.2°
verticality of rotation shaft90.0° ± 0.5°
verticality of dissolution cup90.0° ± 0.5°
coaxiality cup / shaft≤ 2.0 mm
swing of rotation shaft≤ 0.5 mm
swing of rotation basket≤ 0.5 mm
vibration degreeNo obvious vibration
🌀 rotation & drive
rotating shaft speed10 – 300 rpm
dual zone control12 channels divided into 6+6 zones (dual solvent / dual speed workflow)
speed error (6+6 mode)≤ ±0.3 rpm
🌡️ temperature & heating
heating methodWater bath heating
temperature controlRoom temperature – 45 °C, deviation < ±0.2 °C
temperature monitoring12 channels, resolution 0.01 °C
🧪 sampling performance
sampling methodInjection pump sampling
sampling channels12
maximum sampling volume20 mL (sampling accuracy < ±0.1 mL)
sampling points quantity45
minimum sampling intervalFirst time 2 minutes, other points 5 minutes
filterTwo-stage filter (0.45 µm compatible; HPLC-ready workflow)
sampling rack156 position test tube rack + 156 liquid phase bottle rack
sampling test tube10 mL test tube / 2 mL liquid phase bottle
⚡ electrical & dimensions
external dimensions Host: 570 × 940 × 630 mm
Sampler: 640 × 445 × 430 mm
power supplyAC220±10%V, 50/60Hz
powerHost: 2.0 kW · Sampler: 0.3 kW
weightHost: 80 kg · Sampler: 40 kg
✅ compliance
standardsUSP, ChP + Mechanical Validation Guidelines for dissolution meters

🧩 system architecture: Host vs Sampler (what is where)

Host (dissolution tester)
primary role12-cup dissolution platform with validation-relevant mechanical alignment and water bath heating
drive conceptDual drive shaft system (6+6 zones) supporting dual solvent / dual speed test designs
cup positioningAutomatic center positioning, orientation & locking (centrality change after 1000 unload cycles ≤ 0.3 mm)
automatic liftingIntelligent automatic lifting method; electric lifting column for repeatable head height and shaft centering
temperatureRT–45°C control (±0.2°C) with 12-channel monitoring (0.01°C resolution)
host power / size / weight2.0 kW · 570×940×630 mm · 80 kg
Sampler (automatic sampling workstation)
primary role12-channel injection-pump sampling, online filtration, sample collection, replenishment and cleaning
sampling accuracyUp to 20 mL, accuracy < ±0.1 mL
interval controlFirst point 2 min; other points 5 min
collection workflow156-position racks; supports test tubes and liquid phase bottles for LC/HPLC workflows
sampler power / size / weight0.3 kW · 640×445×430 mm · 40 kg

⚙️ mechanical & temperature dominance (validation-grade)

coaxial paddle/basket design Same host supports paddle method, basket method, rotary cylinder, paddle disc, small cup and immersion pool method; sealing rings at coaxial connections to prevent long-term looseness; switching is fast after initial height positioning.
dual-bearing shaft fixation Rotating shaft top fixation with double bearing design supports long-term vertical and coaxial state during operation.
automatic lifting system Automatic lifting platform keeps head horizontal long-term and reduces mechanical drift risk during continuous experiments.
temperature control Handheld and fixed lifting high-precision probes; temperature control accuracy ≤ ±0.2 °C.

💊 dosing & anti-evaporation workflow (tablets / capsules / granules)

dosing deviceIntegrated automatic dosing and anti-evaporation cover; automatic + manual synchronized dosing supported
fast cleaningQuick detachable dozer enables complete cleaning in ~30 seconds; minimizes residue carryover risk
sampling position controlIntegrated sampling needle keeps sampling position unchanged during sequences

🧾 software, user management & integrity (regulatory aligned)

user managementAt least 3 levels (administrator, supervisor, operator); preset 1000 login accounts; groups & role permissions
audit trailLogin/operation/experiment/exception records; protected electronic data (non-editable / non-deletable); ~25,000 records
backup & remoteUSB or enterprise server real-time backup; remote view/print via enterprise server login
paperless reportsNetwork printer; storage on instrument/USB/server; search & print by experiment
remote OS upgradeSupported (remote upgrade services based on customer needs)

🧪 sampling & filtration (HPLC-ready workflow)

injection pump sampling12-channel injection pump sampling with independent pipelines
two-stage filterOnline secondary filtration; filter replacement manual/automatic; compatible with common 0.45 µm filters
direct-to-vialsSampling to liquid vials/tubes; efficient for QC and stability programs
replenishment & cleaningAutomatic liquid replenishment + automatic cleaning to stabilize medium volume and reduce manual workload

🧩 optional: COLO-260DT mechanical qualification system

COLO-260DT Mechanical Qualification System (SKU: PRO6782) combines third-party metrology instruments with workstation software to increase verification frequency and improve integrity. Bluetooth real-time transmission to PC records and displays parameters quantitatively in real time.

3Q services: IQ / OQ / PQ available.

📎 COLO.Science knowledge

Knowledge hub and documentation base:
COLO.Science: colo.science

📦 standard configuration list (reference scope)

No. Description Qty
1COLO-DT1206AT Dissolution Tester (SKU: PRO6781)1 set
Includes (Host)
2Drive Head, 12 Positions1 pc
3Automatic lifting device1 pc
48.0 Inch High-Resolution Touch Screen1 pc
5Temperature monitoring system1 ea
6Automatic lifting sampling device1 ea
7Vessel cover12 ea
8Water tank1 ea
91000 mL Glass Vessel12 ea
10SS 316L Shaft12 ea
11SS 316L Paddle Blade12 ea
12Top for basket with stirring shaft12 ea
13Basket without cover, 40 Mesh12 ea
14Mobile temperature sensor (PT100)1 ea
15Sample delivery tray12 ea
16Calibration Ball (Φ25 mm)12 ea
17Accessory rack1 ea
18Software (data integrity compliant; >1000 accounts; >1000 storage methods)1 ea
Automatic sampling workstation (Sampler)
198-channel syringe pump with secondary online filtering system1 ea
20Sample collector, 104 positions1 ea
21Rack for HPLC vials (1.5 mL)1 ea
22Glasses (Φ16×100 mm), 49 pcs/box4 box
23PE filter head (35 µm), 500 pcs/pack2 ea
Manual sampling device (included for flexibility)
24PEEK Sampling probe12 pc
25Manual sampling locator1 ea
26Sampling probe fixture12 pc
27Silicone dust plug12 pc
Documents
28Installation automated system (including IQ)1 ea
29Operational Qualification (OQ)1 ea
30Performance Qualification (PQ)1 ea
31Operating manual1 ea
32Inspection report1 ea
33Certification1 ea
34Warranty Card1 ea
*Configuration list is a reference scope; final contents are defined by order confirmation and approved quotation.

🔧 technical support: phone / email / remote / on-site
📦 spare parts: dedicated warehouse, key supplier agreements
🛠️ annual maintenance: 1–2 in-depth inspections per year
✅ compliance: USP / ChP + mechanical validation principles

📌 Contact & Support

Headquarters address
Polje ob Sotli 4
SI-3255, Slovenia
For quotation requests, please include your vessel count, sampling schedule (points/intervals), filter workflow (HPLC vials / tubes) and compliance needs (paperless / audit trail / server backup).
Quick contact
Web: colo.si
Email: sales@colo.si
Knowledge hub: COLO.Science
Manufacturer & configuration notice (important):
COLO-DT1206AT systems are supplied in configurations aligned with confirmed application needs and workflow requirements (e.g., tablets/capsules/granules dosing, sampling rack format, filtration workflow, data integrity policies). Therefore, the specifications and included components presented in this document are provided for general information and may represent a typical reference configuration.

For procurement and tender purposes, the only valid and binding specification is the official COLO quotation and the accompanying technical specification that is engineering-approved (issued in writing and signed/authorized by COLO). Any deviations, options, accessory scope and software functions are defined exclusively in that approved quotation package.