COLO.Science · Technical Specification
MAGA19 · Technical Specification
| instrument identity | |
|---|---|
| model | MAGA19 |
| brand / line | COLO.Science · COLO Magnetic Stirrers |
| instrument type | Magnetic stirrer with hotplate (analogue temperature control) |
| intended use | Routine heating and mixing of laboratory media; everyday workflows in research, QC and education. |
| 🌀 stirring performance | |
| max stirring volume | 20 L (H₂O reference) |
| speed range | 0–2000 rpm (analogue setting) |
| driving mode | Motor |
| stirring bar | PTFE, 30–80 mm |
| 🔥 heating & temperature control | |
| temperature range | RT+5°C to 380°C |
| temperature control | Analogue temperature control |
| temperature stability | ±5°C |
| temperature units | °C (analogue) |
| safety note | Heat indicator; dedicated heating ON/OFF button helps prevent unintentional heating |
| 🧱 construction & electrical | |
| hotplate size | 190×190 mm |
| working surface | Ceramic (chemical resistant) |
| heat output | 600 W |
| motor rating output | 9 W |
| protection class | IP42 (DIN EN 60530) |
| power supply | 220 V / 50–60 Hz |
| dimensions (W×D×H) | 203×344×94 mm |
| net / gross weight | 4 / 5 kg |
| permissible ambient | 5–40°C |
| permissible humidity | Up to 80% RH |
| analogue control | Simple knob regulation for temperature and speed—ideal for routine lab work. |
| ceramic hotplate | Chemical-resistant ceramic surface for durability with common laboratory reagents. |
| elevated control panel | Designed to help protect electronics and controls from leaking liquids. |
| front panel operation | Temperature and speed regulation knob placed for fast daily operation. |
| safety & usability | Heat indicator + separate heating ON/OFF button to reduce unintentional heating. |
| buffer and reagent preparation |
| routine heating & mixing in analytical chemistry |
| sample conditioning in QC |
| general education lab heating/stirring |
| dissolution, dissolution aid and controlled warming workflows |
| application fit | If this model does not match your workflow, COLO.Science can propose a suitable configuration or alternative model. |
| related models | Digital model: MAGD19 (PID + dual sensor). Other analogue variants exist within the MAGA/MAGE family. |
| topic | recommendation | note |
|---|---|---|
| temperature approach | For repeatability, keep vessel type + fill volume consistent between runs | Analogue control depends on load and ambient conditions |
| safe operation | Use the heating ON/OFF button and observe residual heat via indicator | Reduces risk of unintentional heating |
| spill prevention | Keep the working area dry; wipe spills promptly | Helps protect the control panel and electronics |