COLO.Science · Technical Specification
MTP200
Thermo Shaker for Microplates · Heating and Shaking Platform · Two-Plate Capacity
MTP200 Thermo Shaker for Microplates is a compact bench-top laboratory instrument designed for controlled incubation and shaking of ELISA microplates, 96/384-well microplates and 96-well tissue culture plates. The system combines dry heating, orbital shaking and timed operation in one practical platform for routine bio-analytical, diagnostic, research and quality control workflows.
Microplate thermo shaker RT+5°C to 80°C 200–1600 rpm 2 microplates Timer 1 min–99h59min Heating film Brushless DC motor PID temperature control 150 W 7.0 kg
Document type: Technical Specification Sheet
Product model: MTP200 Thermo Shaker for Microplates
Application formats: ELISA microplates · 96/384-well microplates · 96-well tissue culture plates
Format: A4 landscape · COLO.Science TechSpec v2.3 · Stable six-page layout
COLO.Science MTP200 thermo shaker for microplates main unit
MTP200 · thermo shaker for microplates · main unit
Model MTP200
Address / HQ Polje ob Sotli 4
SI-3255, Slovenia
Page 1 / 6
COLO.Science logo MTP200 · Thermo Shaker for Microplates
Technical data sheet · Informational document · Controlled electronic document
Manufacturer contact: sales@colo.si · +386 64 222 724
MTP200 · technical specification Bench-top microplate thermo shaker with controlled heating, shaking and timing
RT+5°C to 80°C 200–1600 rpm Two microplates PID control Brushless DC motor Heating film 1 min–99h59min timer — Dedicated microplate incubation and shaking platform
📋 Product Overview
Application profile
ELISA workflows: shaking and incubation of ELISA microplates in routine diagnostic and research work.
Microplate formats: suitable for 96/384-well microplates and 96-well tissue culture plates.
Bio-analytical work: supports enzyme reactions, incubation steps, reagent mixing and temperature-controlled plate handling.
Bench-top use: compact footprint for daily laboratory operation without transferring plates between separate devices.
Design and handling advantage
Two-plate capacity: allows simultaneous handling of two microplates or culture plates.
Stable heating: heating film method supports controlled microplate incubation up to 80°C.
Repeatable shaking: 200–1600 rpm shaking range supports routine microplate mixing protocols.
Long protocols: timer setting from 1 minute to 99 hours 59 minutes supports short and extended workflows.
Key features
Temperature range: RT+5°C to 80°C for controlled heating of microplates and culture plates.
Temperature accuracy: ≤ ±0.5°C with 0.1°C display accuracy.
Uniformity: ≤ ±0.5°C temperature uniformity across the working area.
Heating time: ≤ 10 minutes from room temperature to 80°C.
Motor system: brushless DC motor for stable operation and reduced maintenance.
Control system: PID intelligent temperature control for consistent incubation conditions.
Core technical summary
ParameterSpecification
ModelMTP200
Product typeThermo shaker for microplates
Temperature rangeRT+5°C to 80°C
Shaking speed200–1600 rpm
Capacity2 pcs microplates or culture plates
Timer1 min to 99 h 59 min
Power150 W
Dimensions280 × 270 × 140 mm
Weight7.0 kg
Temperature rangeRT+5°C to 80°C
Shaking speed200–1600 rpm
Capacity2 microplates
Timer1 min–99h59min
Page 2 / 6
📊 Technical Specifications
Main technical data
ParameterSpecification
ProductMTP200 Thermo Shaker for Microplates
Application formatELISA microplates, 96/384-well microplates and 96-well tissue culture plates
Temperature rangeRT+5°C to 80°C
Temperature accuracy≤ ±0.5°C
Display accuracy0.1°C
Temperature uniformity≤ ±0.5°C
Heating time≤ 10 minutes from room temperature to 80°C
Time setting1 minute to 99 hours 59 minutes
Shaking speed range200 to 1600 rpm
Heating methodHeating film
Capacity2 pcs microplates or culture plates
Motor / controlBrushless DC motor and PID intelligent temperature control
Power150 W
VoltageAC 220 V or 110 V / 50–60 Hz
Dimensions W × D × H280 × 270 × 140 mm
Weight7.0 kg
Operation and selection notes
TopicTechnical note
Workflow typeDedicated heating and shaking platform for microplate-based workflows.
Plate capacityDesigned for two microplates or culture plates at the same time.
Temperature profileHeating-only system, suitable when active cooling is not required.
Routine useUseful for ELISA, enzyme reactions, PCR sample preparation and biochemical protocols.
Control methodPID intelligent temperature control supports stable incubation conditions.
Mixing range200–1600 rpm range covers common plate shaking protocols.
Instrument sizeCompact 280 × 270 × 140 mm bench-top format for routine laboratory placement.
Power setupVoltage version should be confirmed before order confirmation.
Specification note
Plate selection: confirm ELISA, PCR, 96-well culture plate or 384-well microplate format.
Heating requirement: verify that RT+5°C to 80°C is suitable for the intended protocol.
Throughput: confirm whether two-plate capacity is sufficient for routine laboratory work.
Technical values are provided for orientation and product selection. Final delivery configuration, voltage version and documentation should be confirmed through the official COLO.Science quotation or order confirmation.
Page 3 / 6
⚙️ Functional Summary and Visual Support
Temperature control
Heating range: RT+5°C to 80°C.
Heating method: heating film for microplate incubation.
Control: PID intelligent temperature control.
Display: 0.1°C display accuracy.
Shaking performance
Speed range: 200 to 1600 rpm.
Capacity: two microplates or culture plates.
Motor: brushless DC motor for stable operation.
Use: repeatable plate mixing workflows.
Laboratory operation
Timer: 1 min to 99 h 59 min.
Handling: bench-top microplate operation.
Protocols: enzyme, ELISA and PCR preparation workflows.
Use level: daily routine laboratory work.
🧪 Microplate Chamber and Configuration Reference
COLO.Science MTP200 thermo shaker for microplates open unit with plate chamber
MTP200 open unit view · Microplate chamber reference
Configuration checklist
Plate format: confirm ELISA microplate, PCR plate, 96-well culture plate or 384-well microplate format.
Temperature requirement: confirm the target incubation temperature and whether 80°C maximum is sufficient.
Shaking requirement: confirm required speed range and protocol tolerance for 200–1600 rpm.
Capacity requirement: confirm whether two-plate capacity is enough for routine throughput.
Voltage version: confirm AC 220 V or 110 V before procurement.
Practical configuration note
Dedicated microplate platform: MTP200 is selected when the laboratory primarily works with microplates or culture plates.
Not a tube-block system: for tube-specific interchangeable blocks, a different thermo shaker platform may be more suitable.
Heating-only workflow: for active cooling, choose a cooling thermo shaker model instead.
Routine plate work: ideal for two-plate incubation and shaking in ELISA, biochemical and research workflows.

Configuration notice — microplate workflow must be confirmed before quotation

MTP200 is a dedicated microplate thermo shaker. Final suitability should be confirmed according to plate format, working temperature, shaking speed, protocol duration, voltage version and required throughput.

Page 4 / 6
COLO.Science · Applications and Delivery Notes
🧬 Typical Applications
ELISA and microplates
Shaking and incubation of ELISA microplates.
Support for 96/384-well microplate formats.
Routine bio-analytical and diagnostic plate workflows.
Enzyme reactions
Enzyme reactions and enzyme deactivation steps.
Temperature-controlled reagent mixing.
Repeatable incubation conditions for laboratory protocols.
PCR preparation
PCR sample preparation workflows.
Short-term handling of DNA libraries and enzymes.
Temperature-controlled biological and biochemical samples.
📦 Standard Delivery and Ordering Notes
Standard delivery reference
Main unit: MTP200 Thermo Shaker for Microplates.
Power cable: voltage version to be confirmed before order.
Documentation: user manual or quick-start documentation according to current delivery set.
Configuration: final delivery content depends on quotation and order confirmation.
Recommended selection questions
Which plate format will be used: ELISA, PCR, 96-well culture plate or 384-well plate?
Is the required workflow heating only, or is active cooling required?
What shaking speed range is required for the protocol?
Is two-plate capacity sufficient for routine throughput?
Which voltage version is required for the laboratory?
📊 Model and Capacity Summary
Model Capacity Temperature range Shaking range Power Dimensions / weight
MTP200 2 microplates / culture plates RT+5°C to 80°C 200–1600 rpm 150 W 280 × 270 × 140 mm / 7.0 kg

Ordering note

Exact delivery content may depend on current catalog status, order confirmation, voltage version and procurement documentation. Before ordering, confirm the intended plate format, laboratory voltage, required temperature range, shaking speed and protocol duration.

Page 5 / 6
COLO.Science · Final Support Page
Manufacturer and support
COLO Lab Experts
Polje ob Sotli 4, SI-3255, Slovenia
Selection guidance: Send the plate format, working temperature, required shaking speed, protocol duration and throughput requirements. COLO.Science can help confirm whether MTP200 is suitable for your microplate incubation and shaking workflow.
Quick contact
COLO.Science · MTP200 microplate thermo shaker support

Need help confirming the correct microplate shaker configuration?

Send the plate format, incubation temperature, shaking speed, protocol duration and throughput requirements. COLO.Science can help confirm whether MTP200 is the right thermo shaker for your laboratory workflow.

Web: colo.si
Official configuration and manufacturer-confirmed specification notice:
This technical specification is provided for orientation, product selection and general information only. It does not represent the final binding technical specification, delivered configuration, accessory set, procurement requirement or acceptance criterion for a specific unit. The final official technical specification is only the specification confirmed by the manufacturer and issued for the exact configuration through an official COLO.Science quotation, proforma invoice, contract document, order confirmation or manufacturer-approved technical offer. Any values, options, accessories or configurations shown in this document must be verified for the specific delivery and should not be used as an exclusion or elimination criterion in procurement procedures without written manufacturer confirmation.
Page 6 / 6