ALEMADR Thermo Shaker Incubator is a compact constant-temperature mixer designed to combine temperature control, oscillation and timing in one laboratory instrument.
The family includes dry bath heating models and thermo shaker incubator models with heating, cooling and oscillation functions.
Interchangeable thermo blocks allow the system to be adapted for PCR plates, microplates, centrifuge tubes, Falcon tubes and deep-well plate workflows.
Thermo shaker incubatorRT+5°C to 100°CCooling to -20°C0–1500 rpm2 mm amplitudeLCD displayBrushless DC motorTimer 0–99h59minPeltier cooling optionInterchangeable blocks
Setting or program running, timing running, automatic stop, quick stop / start, one-button illumination and two-way automatic switching.
Additional features
Temperature deviation correction, menu button lock and power failure memory.
Continuous operation
Maximum continuous working time: 240 h.
Heating time
Average heating time from 25°C to 100°C: ≤5 min, depending on mode and configuration.
Cooling time
Average cooling time from 100°C to 25°C: ≤8 min; from 25°C to -20°C: ≤8 min, depending on mode and configuration.
Uniformity at 4°C
±0.5°C in thermo block.
Uniformity at 37°C
±0.1°C in thermo block.
Uniformity at 100°C
±0.3°C in thermo block.
Working temperature
+4°C to 40°C.
Safety functions
Multiple protection functions including overheating and overloading protection.
Specification note
Model selection: choose H / HC for dry bath incubation, or MS / MSC when both temperature control and oscillation are required.
Cooling requirement: select HC or MSC when sub-ambient Peltier cooling is required.
Block compatibility: verify tube type, tube diameter, plate format and maximum rpm before final configuration.
Final values depend on installed thermo block, sample format, ambient conditions, operating program and selected model configuration. Feature summary and block configuration continue on the next page to keep this page stable for A4 landscape printing.
Page 3 / 6
⚙️ Feature Summary and Visual Configuration Support
Control and display
LCD: two-line display for set and current temperature, speed and time.
Timer: timed, continuous and programmed operation modes.
Calibration: temperature deviation correction for workflow tuning.
Memory: power failure memory supports safer continuation after interruption.
Drive and operation
Brushless DC motor: long-life, maintenance-free and graphite-pollution-free operation.
Soft start: helps reduce liquid splash at the beginning of operation.
Speed protection: automatic locking if speed is out of control.
Interval mixing: supports programmed mixing and incubation workflows.
Temperature workflow
Heating: up to 100°C depending on selected block and model.
Cooling: Peltier cooling options for HC and MSC variants.
Uniformity: specified values at 4°C, 37°C and 100°C.
Protection: overheating and overloading protection functions.
🧰 Interchangeable Thermo Blocks and Visual Support
ALEMADR thermo block set · K / L / J / M block visual reference
Block image references
K / L / J / M blocks
F / H / G / I blocks
A / C / B / E blocks
Additional block visual reference
Configuration checklist
Temperature profile: confirm whether the protocol requires heating only, sub-ambient cooling or both.
Sample format: define tube size, plate type, PCR format, Falcon tube volume or deep-well plate requirement.
Mixing requirement: confirm whether incubation only is sufficient or oscillation up to 1500 rpm is required.
Block selection: choose the block model and verify maximum temperature and maximum rpm for that block.
Model choice: select H / HC for dry bath incubation, or MS / MSC when shaking is required.
Configuration notice — model options must be confirmed before quotation
ALEMADR instruments are selected according to temperature range, cooling requirement, oscillation requirement and thermo block configuration. The detailed optional thermo block table continues on the final page and uses the free accumulator space above the locked contact block.
Page 4 / 6
COLO.Science · Optional Thermo Blocks
📊 Optional Thermo Blocks
Code
Model
Aperture / tube or plate format
Max. Temp.
Max. rpm
AS-01051-01
A
96 × 0.2 ml standard plate
100°C
1500
AS-01051-02
B
54 × 0.5 ml centrifuge tube
100°C
1500
AS-01051-03
C
35 × 1.5 ml centrifuge tube
100°C
1500
AS-01051-04
D
35 × 2.0 ml centrifuge tube
100°C
1500
AS-01051-05
E
15 × 0.5 ml + 20 × 1.5 ml centrifuge tube
100°C
1500
AS-01051-06
F
24 tubes, diameter ≤ 12 mm
100°C
1200
AS-01051-07
G
12 × 15 ml Falcon tube
100°C
800
AS-01051-08
H
6 × 50 ml Falcon tube
100°C
750
AS-01051-09
I
103 × 67 × 30 mm square slot module
100°C
1500
AS-01051-10
J
96 × 0.2 ml microplate / enzyme-labeled plate
100°C
1500
AS-02031-01
PCR-A
96 × 0.2 ml PCR tube holder
100°C
1500
AS-01051-16
PCR-B
PCR plate 96X
100°C
1500
AS-01051-11
K
24 × 5 ml centrifuge tube
100°C
1200
AS-01051-12
L
Special template for deep hole plate
80°C
800
AS-01051-13
M
15 × 5 ml Eppendorf centrifuge tube
100°C
1200
AS-01051-14
N
35 × 1.5 / 2 ml tubes
100°C
1500
AS-01051-15
O
20 × 0.5 ml + 12 × 1.5 ml
100°C
1500
AS-01051-16
P
20 × 0.2 ml + 12 × 1.5 ml
100°C
1500
Tube blocks
B / C / D / E / F / K / M / N / O / P: routine centrifuge tube and Eppendorf tube formats.
Plate blocks
A / J / PCR-A / PCR-B / L: PCR, microplate, enzyme-labeled plate and deep-well plate formats.
Falcon and slot modules
G / H / I: Falcon tube and square slot module configurations for larger vessels.
Block configuration note
Maximum temperature and maximum rpm are block-dependent. The final thermo block set should be confirmed according to sample vessel format, required temperature range, filling volume and shaking intensity.
Page 5 / 6
COLO.Science · Final Support Page
Manufacturer and support
COLO Lab Experts
Polje ob Sotli 4, SI-3255, Slovenia
Selection guidance: Send the temperature range, cooling requirement, shaking requirement, sample tube or plate format and required thermo blocks.
COLO.Science can help confirm the correct ALEMADR model and block configuration for your laboratory workflow.
COLO.Science · ALEMADR thermo shaker incubator configuration support
Need help choosing the correct ALEMADR model and thermo block set?
Send the tube or plate format, required temperature range, cooling requirement, shaking speed and protocol duration.
COLO.Science can help confirm whether ALEMADR-H, ALEMADR-HC, ALEMADR-MS or ALEMADR-MSC is the correct configuration.
Official configuration and manufacturer-confirmed specification notice:
This technical specification is provided for orientation, product selection and general information only. It does not represent the final binding technical specification, delivered configuration, accessory set, procurement requirement or acceptance criterion for a specific unit. The final official technical specification is only the specification confirmed by the manufacturer and issued for the exact configuration through an official COLO.Science quotation, proforma invoice, contract document, order confirmation or manufacturer-approved technical offer. Any values, options, accessories or configurations shown in this document must be verified for the specific delivery and should not be used as an exclusion or elimination criterion in procurement procedures without written manufacturer confirmation.