ALEMADR Thermo Shaker Incubator is a compact constant-temperature mixer designed to combine temperature control, oscillation and timing in one laboratory instrument. The family includes dry bath heating models and thermo shaker incubator models with heating, cooling and oscillation functions. Interchangeable thermo blocks allow the system to be adapted for PCR plates, microplates, centrifuge tubes, Falcon tubes and deep-well plate workflows.
Thermo shaker incubator RT+5°C to 100°C Cooling to -20°C 0–1500 rpm 2 mm amplitude LCD display Brushless DC motor Timer 0–99h59min Peltier cooling option Interchangeable blocks
Document type: Technical Specification Sheet
Product family: ALEMADR Thermo Shaker Incubator
Models: ALEMADR-H · ALEMADR-HC · ALEMADR-MS · ALEMADR-MSC
Format: A4 landscape · COLO.Science TechSpec v2.3
COLO.Science ALEMADR thermo shaker incubator main unit
ALEMADR · thermo shaker incubator · main unit
Family ALEMADR
Address / HQ Polje ob Sotli 4
SI-3255, Slovenia
Page 1 / 6
COLO.Science logo ALEMADR · Thermo Shaker Incubator
Technical data sheet · Informational document · Controlled electronic document
Manufacturer contact: sales@colo.si · +386 64 222 724
ALEMADR · technical specification Constant temperature mixer with heating, cooling, oscillation and timing functions
LCD display PID control Soft start Power failure memory Temp. calibration Interval mixing Overheating protection — Flexible dry bath and thermo shaker platform for tube, plate and block-based workflows
📋 Product Overview
Application profile
Sample incubation: suitable for controlled heating of tubes, PCR formats, microplates and thermo block-based workflows.
Mixing and temperature control: MS and MSC models combine oscillation with heating or cooling for reproducible sample preparation.
Cold and hot workflows: HC and MSC configurations use Peltier cooling for sub-ambient temperature control.
Modular laboratory use: replaceable blocks support centrifuge tubes, Falcon tubes, PCR plates, microplates and deep-well plate formats.
Design and handling advantage
Easy block exchange: thermostatic blocks can be changed conveniently according to sample format and protocol.
LCD operation: the two-line display shows set and current parameters for temperature, shaking speed and time.
Reliable drive system: intelligent brushless DC motor supports accurate speed control, soft start and maintenance-free operation.
Safety functions: protection functions include overheating, overloading, menu button lock and power failure memory.
Key features
Temperature range: RT+5°C to 100°C for heating models, with cooling configurations down to -10°C or -20°C depending on model.
Mixing speed: thermo shaker models support 0–1500 rpm mixing speed control.
Temperature stability: ±0.1°C with 0.1°C resolution and 0.2°C temperature control accuracy.
Timing range: 0 to 99 h 59 min for programmed or timed operation.
Uniformity: thermo block uniformity values are specified at 4°C, 37°C and 100°C.
Connectivity option: USB / Bluetooth connection with external firmware setup option.
Core technical summary
ParameterSpecification
Model familyALEMADR
Model variantsALEMADR-H, ALEMADR-HC, ALEMADR-MS, ALEMADR-MSC
Temperature rangeRT+5°C to 100°C / -10°C to 100°C / -20°C to 100°C depending on model
Mixing speed0–1500 rpm on MS / MSC models
Mixing amplitude2 mm
Temperature resolution0.1°C
Timer0 to 99 h 59 min
Power supplyAC110–220V±10% / 50–60Hz / 60W · Output DC12V / 4.9A
BlocksOptional interchangeable thermo blocks
Temperature rangeRT+5°C / -20°C to 100°C
Mixing speed0–1500 rpm
Amplitude2 mm
Timer0–99h59min
Page 2 / 6
📊 Technical Specifications
Model comparison
ParameterALEMADR-HALEMADR-HCALEMADR-MSALEMADR-MSC
TypeDry bath incubatorDry bath incubatorThermo shaker incubatorThermo shaker incubator
Temperature control rangeRT+5°C–100°C-10°C–100°CRT+5°C–100°C-20°C–100°C
Cooling methodxPeltierxPeltier
Mixing speed controlxx0–1500 rpm
Cooling systemNoYesNoYes
Dimension W×D×H200 × 220 × 90 mm220 × 240 × 90 mm
NW / GW3.2 / 4 kg3.7 / 6 kg
Shared parameters
ParameterSpecification
Temperature resolution0.1°C
Temperature stability±0.1°C
Temperature control accuracy0.2°C
Temperature accuracy at 37°C0.1°C
Mixing amplitude2 mm
Speed accuracy±1 rpm
Shell materialABS
Drive modeMultidimensional drive
Calibration coefficient range0.936–1.063 (±0.063)
Timer0 to 99 h 59 min
Temperature sensorPt100 A Class
Power supplyAC110–220V±10% / 50–60Hz / 60W · Output DC12V / 4.9A
Operation and protection functions
FunctionTechnical note
Running functionSetting or program running, timing running, automatic stop, quick stop / start, one-button illumination and two-way automatic switching.
Additional featuresTemperature deviation correction, menu button lock and power failure memory.
Continuous operationMaximum continuous working time: 240 h.
Heating timeAverage heating time from 25°C to 100°C: ≤5 min, depending on mode and configuration.
Cooling timeAverage cooling time from 100°C to 25°C: ≤8 min; from 25°C to -20°C: ≤8 min, depending on mode and configuration.
Uniformity at 4°C±0.5°C in thermo block.
Uniformity at 37°C±0.1°C in thermo block.
Uniformity at 100°C±0.3°C in thermo block.
Working temperature+4°C to 40°C.
Safety functionsMultiple protection functions including overheating and overloading protection.
Specification note
Model selection: choose H / HC for dry bath incubation, or MS / MSC when both temperature control and oscillation are required.
Cooling requirement: select HC or MSC when sub-ambient Peltier cooling is required.
Block compatibility: verify tube type, tube diameter, plate format and maximum rpm before final configuration.
Final values depend on installed thermo block, sample format, ambient conditions, operating program and selected model configuration. Feature summary and block configuration continue on the next page to keep this page stable for A4 landscape printing.
Page 3 / 6
⚙️ Feature Summary and Visual Configuration Support
Control and display
LCD: two-line display for set and current temperature, speed and time.
Timer: timed, continuous and programmed operation modes.
Calibration: temperature deviation correction for workflow tuning.
Memory: power failure memory supports safer continuation after interruption.
Drive and operation
Brushless DC motor: long-life, maintenance-free and graphite-pollution-free operation.
Soft start: helps reduce liquid splash at the beginning of operation.
Speed protection: automatic locking if speed is out of control.
Interval mixing: supports programmed mixing and incubation workflows.
Temperature workflow
Heating: up to 100°C depending on selected block and model.
Cooling: Peltier cooling options for HC and MSC variants.
Uniformity: specified values at 4°C, 37°C and 100°C.
Protection: overheating and overloading protection functions.
🧰 Interchangeable Thermo Blocks and Visual Support
ALEMADR interchangeable thermo blocks K L J M
ALEMADR thermo block set · K / L / J / M block visual reference
Block image references
ALEMADR K L J M thermo blocks
K / L / J / M blocks
ALEMADR F H G I thermo blocks
F / H / G / I blocks
ALEMADR A C B E thermo blocks
A / C / B / E blocks
ALEMADR additional thermo block visual reference
Additional block visual reference
Configuration checklist
Temperature profile: confirm whether the protocol requires heating only, sub-ambient cooling or both.
Sample format: define tube size, plate type, PCR format, Falcon tube volume or deep-well plate requirement.
Mixing requirement: confirm whether incubation only is sufficient or oscillation up to 1500 rpm is required.
Block selection: choose the block model and verify maximum temperature and maximum rpm for that block.
Model choice: select H / HC for dry bath incubation, or MS / MSC when shaking is required.

Configuration notice — model options must be confirmed before quotation

ALEMADR instruments are selected according to temperature range, cooling requirement, oscillation requirement and thermo block configuration. The detailed optional thermo block table continues on the final page and uses the free accumulator space above the locked contact block.

Page 4 / 6
COLO.Science · Optional Thermo Blocks
📊 Optional Thermo Blocks
CodeModelAperture / tube or plate formatMax. Temp.Max. rpm
AS-01051-01A96 × 0.2 ml standard plate100°C1500
AS-01051-02B54 × 0.5 ml centrifuge tube100°C1500
AS-01051-03C35 × 1.5 ml centrifuge tube100°C1500
AS-01051-04D35 × 2.0 ml centrifuge tube100°C1500
AS-01051-05E15 × 0.5 ml + 20 × 1.5 ml centrifuge tube100°C1500
AS-01051-06F24 tubes, diameter ≤ 12 mm100°C1200
AS-01051-07G12 × 15 ml Falcon tube100°C800
AS-01051-08H6 × 50 ml Falcon tube100°C750
AS-01051-09I103 × 67 × 30 mm square slot module100°C1500
AS-01051-10J96 × 0.2 ml microplate / enzyme-labeled plate100°C1500
AS-02031-01PCR-A96 × 0.2 ml PCR tube holder100°C1500
AS-01051-16PCR-BPCR plate 96X100°C1500
AS-01051-11K24 × 5 ml centrifuge tube100°C1200
AS-01051-12LSpecial template for deep hole plate80°C800
AS-01051-13M15 × 5 ml Eppendorf centrifuge tube100°C1200
AS-01051-14N35 × 1.5 / 2 ml tubes100°C1500
AS-01051-15O20 × 0.5 ml + 12 × 1.5 ml100°C1500
AS-01051-16P20 × 0.2 ml + 12 × 1.5 ml100°C1500
Tube blocks
B / C / D / E / F / K / M / N / O / P: routine centrifuge tube and Eppendorf tube formats.
Plate blocks
A / J / PCR-A / PCR-B / L: PCR, microplate, enzyme-labeled plate and deep-well plate formats.
Falcon and slot modules
G / H / I: Falcon tube and square slot module configurations for larger vessels.

Block configuration note

Maximum temperature and maximum rpm are block-dependent. The final thermo block set should be confirmed according to sample vessel format, required temperature range, filling volume and shaking intensity.

Page 5 / 6
COLO.Science · Final Support Page
Manufacturer and support
COLO Lab Experts
Polje ob Sotli 4, SI-3255, Slovenia
Selection guidance: Send the temperature range, cooling requirement, shaking requirement, sample tube or plate format and required thermo blocks. COLO.Science can help confirm the correct ALEMADR model and block configuration for your laboratory workflow.
Quick contact
COLO.Science · ALEMADR thermo shaker incubator configuration support

Need help choosing the correct ALEMADR model and thermo block set?

Send the tube or plate format, required temperature range, cooling requirement, shaking speed and protocol duration. COLO.Science can help confirm whether ALEMADR-H, ALEMADR-HC, ALEMADR-MS or ALEMADR-MSC is the correct configuration.

Web: colo.si
Official configuration and manufacturer-confirmed specification notice:
This technical specification is provided for orientation, product selection and general information only. It does not represent the final binding technical specification, delivered configuration, accessory set, procurement requirement or acceptance criterion for a specific unit. The final official technical specification is only the specification confirmed by the manufacturer and issued for the exact configuration through an official COLO.Science quotation, proforma invoice, contract document, order confirmation or manufacturer-approved technical offer. Any values, options, accessories or configurations shown in this document must be verified for the specific delivery and should not be used as an exclusion or elimination criterion in procurement procedures without written manufacturer confirmation.
Page 6 / 6