COLO.Science · Technical Specification
ALEMADR-TSHL
Thermo Shaker with Heating Lid · Dry-Block · Dual Block · 200–2000 rpm
ALEMADR-TSHL Thermo Shaker with Heating Lid is a multipurpose thermostatic dry-block shaker designed for sample incubation, catalysis, blending and preservation in microtubes, PCR plates and related tube formats. The instrument combines stable orbital shaking, precise PID temperature regulation and an independently controlled heated lid to help reduce evaporation, improve temperature uniformity and minimize cross-contamination risk during controlled sample processing.
Heating lid Dual block Dry-block shaker 200–2000 rpm 2 mm orbit RT+5°C to 100°C ≤ ±0.2°C @ 37°C LCD display Brushless DC motor
Document type: Technical Specification Sheet
Product: ALEMADR-TSHL Thermo Shaker with Heating Lid
Image reference: PRO6399
Format: Print layout · A4 landscape
COLO.Science ALEMADR-TSHL thermo shaker with heating lid main unit
ALEMADR-TSHL · thermo shaker with heating lid · main unit
Model ALEMADR-TSHL
Address / HQ Polje ob Sotli 4
SI-3255, Slovenia
Page 1 / 4
COLO.Science logo ALEMADR-TSHL · Thermo Shaker with Heating Lid
Technical data sheet · Informational document · Controlled electronic document
Manufacturer contact: sales@colo.si · +386 64 222 724
ALEMADR-TSHL · technical specification Dry-block thermo shaker with dual-block capacity, precise PID temperature control and heating lid
LCD display PID control Dual block 2000 rpm max. Heating lid Temperature calibration — Compact thermostatic shaker for microtubes, PCR plate and dry-block sample preparation workflows
📋 Product Overview
Application profile
Sample incubation: controlled dry-block temperature environment for microtubes and related tube formats.
Catalysis and reaction support: stable temperature regulation and shaking for protocol-controlled sample processing.
Blending and mixing: orbital shaking up to 2000 rpm for efficient tube-based mixing workflows.
Preservation workflows: timed and temperature-controlled operation for selected laboratory sample handling procedures.
Heating lid advantage
Independent control: the heating lid can be controlled automatically or manually.
Evaporation reduction: heated-lid control helps reduce condensation and evaporation during heated tube protocols.
Improved uniformity: lid heating supports more consistent thermal conditions around tube caps and sample positions.
Contamination support: reduced condensation and evaporation can help minimize cross-contamination risk in tube workflows.
Key features
LCD display: simple setup and real-time monitoring of operating parameters.
PID intelligent temperature control: high temperature stability and optimized heating rate.
Dual-block design: two-block configuration for larger usable tube capacity.
Brushless DC motor: quiet operation, long service life and low maintenance.
Built-in calibration: temperature calibration function for better protocol confidence.
Safety protection: built-in over-heating protection for safe and reliable operation.
Core technical summary
ParameterSpecification
ModelALEMADR-TSHL
Product typeThermo shaker with heating lid
Shaking speed200 to 2000 rpm
Orbit2 mm
Block quantity2
Temperature control rangeRT+5°C to 100°C
Temperature accuracy≤ ±0.2°C @ 37°C
Dimensions296 × 212 × 164 mm
Weight6.9 kg
Speed200–2000 rpm
Temp. rangeRT+5°C to 100°C
Accuracy≤ ±0.2°C @ 37°C
Block quantity2 blocks
RT = room temperature. Final block compatibility, tube type and protocol settings should be confirmed before official quotation or publication.
Page 2 / 4
📊 Technical Parameters
ProjectParameter ProjectParameter
Temp. setting range0°C to 100°C Multi cycleYes, max. 99 times
Temp. control rangeRT+5°C to 100°C Auto constant temp. at end of runYes
Timing range1 min to 99 h 59 min / ∞ Auto preheatingYes
Temp. accuracy≤ ±0.2°C @ 37°C Auto runningYes
Display accuracy0.1°C Auto resume to runYes
Temp. uniformity≤ ±0.2°C @ 37°C Block quantity2
Heating lid temp. setting rangeAuto / 0 to +15°C Power450 W
Heating lid temp. control modeAutomatic / Manual VoltageAC220V or AC110V, 50/60Hz
Shaking speed200 to 2000 rpm Fuse250V 3A Φ5×20
Orbit2 mm Dimensions296 × 212 × 164 mm
Heating time≤ 15 min, from 25°C to 100°C Weight6.9 kg
Multi points runningYes, max. 5 points DisplayLCD
🧩 Optional Blocks
Block type / SKU Capacity Maximum speed
PRO4484 96 × 0.2 ml PCR plate 2000 rpm
PRO4483 54 × 0.5 ml centrifuge tube 2000 rpm
PRO4307 35 × 1.5 ml centrifuge tube 2000 rpm
PRO4485 35 × 2.0 ml centrifuge tube 2000 rpm
PRO4486 15 × 0.5 ml + 20 × 1.5 ml centrifuge tube 2000 rpm
Block selection note
Tube format: select the block according to PCR plate, 0.5 ml tube, 1.5 ml tube, 2.0 ml tube or mixed tube requirements.
Protocol speed: optional block configurations listed above support maximum speed up to 2000 rpm.
Custom blocks: additional or custom blocks may be available on request through the COLO.Science team.
Protocol planning note
Temperature: confirm block temperature, lid mode and sample sensitivity before running heated protocols.
Timing: timing can be set from 1 minute to 99 h 59 min or continuous operation.
Program modes: multi-point and multi-cycle running support more structured laboratory workflows.
Additional/custom blocks may be available on request. Final block availability, tube compatibility and protocol parameters should be confirmed before order placement.
Page 3 / 4
🖼️ Visuals, Configuration Guidance and Support
ALEMADR-TSHL thermo shaker with heating lid dry block dual block main unit
ALEMADR-TSHL main unit · dual-block thermo shaker with independently controlled heating lid
Ordering information
ItemValue
ModelALEMADR-TSHL
Product typeThermo shaker with heating lid
Dry-block configurationDual block
Main image referencePRO6399
Speed range200 to 2000 rpm
Temperature control rangeRT+5°C to 100°C
Voltage optionsAC220V or AC110V, 50/60Hz
Configuration checklist
Tube or plate format: confirm PCR plate, 0.5 ml, 1.5 ml, 2.0 ml or mixed tube format.
Block type: select the correct optional block type / SKU for the workflow.
Temperature profile: define target temperature, heating-lid mode and protocol duration.
Speed profile: confirm shaking speed, mixing intensity and sample sensitivity.
Voltage: confirm AC220V or AC110V before order placement.
Manufacturer and support
COLO Lab Experts
Polje ob Sotli 4, SI-3255, Slovenia
Selection guidance: ALEMADR-TSHL should be selected according to tube format, block type, target temperature, shaking speed, lid heating requirement and sample protocol. COLO.Science can help select the correct block type and configuration.
Quick contact
COLO.Science · Thermo shaker configuration support

Need help selecting the correct block type, tube format or protocol parameters?

Send the tube format, sample volume, target temperature, heating time, shaking speed and protocol duration. COLO.Science can help confirm the correct block type and ALEMADR-TSHL configuration for your laboratory workflow.

Web: colo.si
Specification disclaimer:
The information in this document is prepared from the supplied ALEMADR-TSHL product data and image reference. Final values, block availability, voltage configuration, tube compatibility and protocol suitability should be verified before official catalogue publication, quotation issue or print production.
Page 4 / 4