COLO.Science · Technical Specification
GC2000 · Technical Specification
| instrument identity | |
|---|---|
| model | GC2000 |
| instrument type | Gas chromatograph |
| platform positioning | New-generation GC system benchmarked against international leading brands |
| core control architecture | Advanced electronic flow control, microfluidic plate control, and high-precision independent temperature control |
| analytical focus | Strong analytical capability with reliable stability for routine and application-expansion workflows |
| intelligent system functions | |
| self-diagnosis | Supported |
| self-leak detection | Supported |
| carrier gas saving | Supported |
| automatic reminders | Supported |
| system status visibility | Instrument status can be easily monitored for faster troubleshooting |
| pretreatment / accessory compatibility | |
| pretreatment compatibility | Can be matched with solid phase microextraction, headspace, liquid sampler, and related pretreatment equipment |
| application expansion | Designed to support broader method development and multi-scenario laboratory use |
| liquid injection port | Ultra-stable liquid injection port with fully electronic flow control and built-in self-diagnostic function. |
| contamination control | No need for manual soap leak detection, reducing the risk of system contamination. |
| surface treatment option | Optional permanent ultra-deactivated surface treatment for stronger adsorption and corrosive sample handling. |
| pressure control | Ultra-high-precision electronic pressure controller (EPC) with long-term stable control performance. |
| EPC core | Ruby-material EPC core. |
| pressure accuracy | Up to 0.001 psi. |
| column oven class | World-class column oven |
| temperature programming | Supports up to 32-stage / 33-platform temperature programs |
| method adaptability | Adapted to highly complex analytical methods |
| equilibration behavior | Rapid column temperature equilibration for reduced waiting time between analyses |
| operating environment | Human-computer interaction APP based on Android intelligent operating system |
| interface concept | Skeuomorphic graphic UI design with clear monitoring content |
| display | 8-inch color screen |
| screen resolution | 1280 × 720 (RGB) |
| touch operation | Capacitive full-touch operation |
| detector capacity | Supports multiple detector options, up to four detectors at the same time |
| detector options |
|---|
| Flame Ionization Detector (FID) |
| Electron Capture Detector (ECD) |
| Flame Photometric Detector (FPD) |
| Thermal Conductivity Detector (TCD) |
| Mass Selectivity Detector (MS) |
| Triple Quadrupole Mass Spectrometer (MS/MS) |
| application field | application description |
|---|---|
| environment & health | NMTH analysis solutions. According to HJ 604 and HJ 38 standards, the instrument can be configured with a built-in self-priming sampling system, dual-channel single-FID detection, and post-run automatic reverse pipeline cleaning for the determination of NMTHs in ambient air and waste gas from stationary pollution sources. |
| food / agriculture | Multi-residue analysis solutions for pesticides in vegetables and fruits. According to NY/T761 and related standards, the dual-tower liquid autosampler can be used for sample injection, while FPD and ECD dual-column dual-channel detection can support determination of multiple residues of organochlorine and organophosphorus pesticides. |
| method expansion | The GC2000 platform is intended for laboratories that need one flexible instrument capable of supporting multiple detector types, multiple pretreatment modes, and broader analytical method development. |
| daily usability | Self-diagnosis, leak detection and automatic reminders help users identify operating status quickly. |
| sample adaptability | Optional ultra-deactivated injection surfaces improve suitability for adsorption-prone and corrosive samples. |
| method turnaround | Fast oven equilibration helps reduce waiting time between consecutive chromatographic analyses. |
| configuration note | Final detector package, autosampler scope, and pretreatment accessories should be defined in the quotation. |
| application note | Application examples shown in this document represent typical workflow directions and should be validated against the final laboratory method. |
| specification note | This sheet is based on visible source material and feature highlights rather than a full factory numeric datasheet. |