Analytical Balance | 30-500 g Capacity | 0.01-0.1 mg Readability | Internal Calibration

SIENE analytical balance is a touch-screen laboratory balance for demanding 0.01-0.1 mg measurements from 30 to 500 g. The source specification identifies internal calibration, temperature compensation, an anti-vibration filter, RS232 / USB output, LCD backlight touch-screen operation and a 80 mm weighing pan.

30-500 g0.01-0.1 mg readabilityInternal calibrationTemperature compensationAnti-vibration filterRS232 / USBTouch screen80 mm pan
Document type: Technical Specification Sheet
Product family: SIENE Analytical Balance
Capacity: 30-500 g
Calibration: Internal calibration
Series characteristic: 0.01-0.1 mg analytical weighing with touch-screen operation
Format: A4 landscape | COLO.Science TechSpec v2.5
ANB-SIENE analytical balance
ANB-SIENE analytical balanceTouch screen | glass windshield
ANB-SIENE analytical balance | touch screen | internal calibration | glass windshield
Measuring range30-500 g
d = 0.01-0.1 mg
Address / HQPolje ob Sotli 4
SI-3255, Slovenia
Page 1 / 5
COLO.Science logoSIENE | Analytical Balance Series
Technical data sheet | Informational document
Capacity: 30-500 g
SIENE | analytical balanceInternal calibration, 0.01-0.1 mg readability and touch-screen operation
Max 500 gd = 0.01-0.1 mgInternal calibrationRS232 / USB outputHigh-precision weighing for demanding analytical measurements
Series Overview
Calibration, stability and operation
Internal calibration: provides fast and high-precision calibration for analytical balance workflows.
Temperature compensation: supports stable measurements under routine laboratory conditions.
Anti-vibration filter: helps reduce the effect of environmental vibration on 0.01-0.1 mg measurements.
Touch-screen operation: LCD with backlight and touch screen for convenient weighing setup.
Data handling and usability
PC data workflow: optional communication software can collect data and control the measurement process.
Cursor output: balance measurement data can be written to Excel, Word and other documents following the cursor.
Colour touch screen: direct access to frequent settings with a high-resolution LCD touch display.
Built-in records: date, time and temperature display are adjustable for traceable weighing routines.
Key product features from source table
Model range: PRO7036-PRO7040, 30 g to 500 g.
Readability: 0.01 mg for 30 g model; 0.1 mg for 120-500 g models.
Repeatability: ±0.05 mg for 30 g; ±0.2 mg for 120-500 g models.
Linearity: ±0.03 mg for 30 g; ±0.2 mg for 120-500 g models.
Output: RS232 / USB communication interface.
Pan: Ø80 mm weighing pan for these analytical models.
Models30-500 g
Readability0.01-0.1 mg
Chamber360 x 210 x 320 mm
Stabilization3 s
Page 2 / 5
Models and Technical Specifications
Model selection and source-table values
SKUModelMeasuring rangeReadabilityRepeatabilityLinearityCalibrationOutput interface
PRO7036ANB-SIENE 30g/0.01 mg30 g0.01 mg±0.05 mg±0.03 mgInternalRS232 / USB
PRO7037ANB-SIENE 120g/0.1 mg120 g0.1 mg±0.2 mg±0.2 mgInternalRS232 / USB
PRO7038ANB-SIENE 220g/0.1 mg220 g0.1 mg±0.2 mg±0.2 mgInternalRS232 / USB
PRO7039ANB-SIENE 320g/0.1 mg320 g0.1 mg±0.2 mg±0.2 mgInternalRS232 / USB
PRO7040ANB-SIENE 500g/0.1 mg500 g0.1 mg±0.2 mg±0.2 mgInternalRS232 / USB
Weighing system and performance
ParameterSpecification
Measuring range30 / 120 / 220 / 320 / 500 g
Readability0.01 mg / 0.1 mg by model
Repeatability±0.05 mg for 30 g; ±0.2 mg for 120-500 g
Linearity±0.03 mg for 30 g; ±0.2 mg for 120-500 g
Stabilization3 s
Weighing modesBasic weighing, piece weighing, percentage weighing, density determination, powder weighing
Peel rangeFull range
Display, interface and construction
ParameterSpecification
DisplayLCD with backlight, touch screen
InterfaceRS232 / USB
Pan sizeØ80 mm
Power requirementsAdapter input: 100-240 V ~ 200 mA, 50-60 Hz; output: 5 VDC 2.5 A
Overall size360 x 210 x 320 mm
N.W. / G.W.5 kg / 7.3 kg
Shipping dimension50 x 36 x 47 cm
Source note: Model/SKU values and measuring ranges were updated from the supplied SIENE model list and technical table. Other SIENE characteristics remain aligned with the existing technical specification template.
Page 3 / 5
Applications, Delivery, Options and Calibration Weights
SIENE analytical balance
SIENE analytical balanceTouch screen | internal calibration
SIENE analytical balance | internal calibration | touch screen | 0.01-0.1 mg readability
Built-in applications and operating modes
Standard analytical weighing: high-precision weighing for laboratory samples.
Parts counting: counting down to 1 mg in laboratory conditions; 10 mg minimum weight, resolution counting 210,000.
Percent weighing: compare measured mass to a reference.
Density weighing: direct reading function for density workflows with optional hydrostatic set.
Animal weighing: supports unstable sample measurement.
Check and target weighing: upper/lower limit checks, target weighing, summarization, gross/net/tare and peak hold.
Optional accessories
Optional thermal printer
Optional thermal printerMeasurement record output
Optional thermal printer for laboratory balance
OIML E2 calibration weight
OIML E2 calibration weightRecommended analytical balance control weight
Optional OIML E2 calibration / control weight
Ordering note: Source PDF recommends a 200 g E2 class calibration/control weight. Confirm required nominal masses, E2 certificates and calibration/control-weight procedure for the selected SIENE model and laboratory SOP.
Page 4 / 5
COLO.Science | Product Support
Manufacturer and support
COLO Lab Experts
Polje ob Sotli 4, SI-3255, Slovenia
Selection guidance: Send the intended weighing range, sample type, minimum sample mass, printer/data-output requirement, calibration routine and documentation expectations.
Quick contact
Web: colo.si
Series: SIENE analytical balance
COLO.Science | SIENE analytical balance support

Need help configuring a SIENE analytical balance?

Send the weighing range, sample type, routine minimum weight, printout requirement, PC data workflow and calibration routine. COLO.Science can confirm the SIENE configuration, printer, software and E2 calibration/control-weight set.

Main weighing navigation

Official configuration notice: This document is provided for orientation and product selection. It does not replace the binding specification, delivered configuration, accessory set or acceptance criteria confirmed in the official COLO.Science quotation, proforma invoice, order confirmation or manufacturer-approved technical offer. Confirm model configuration, internal calibration routine, calibration/control masses, certificates, printer, software and accessories for the specific order. Specifications may change without notice.
Page 5 / 5